video corpo

GTE 10
1 /12Pages

GTE 10

GTE 10
1 /12Pages

Catalog excerpts

GTE 10-1

SagiCofim Ecoefficiency for Indoor Air Quality

 Open the catalog to page 1
GTE 10-3

Adjusting damper 100 pitch SagiCofim Use range of the damper: in ATEX version in SAFE area - 20 ° C< t < + 50 ° C - Vmax 15 m/s - Pmax 3000 Pa - 20 ° C < t < + 70 ° C - Vmax 25 m/s - Pmax 3000 Pa A B C D E F G H I Specific features of the product Note: in the ATEX version, the damper is equipped with a a specific label and earthing cable. To establish the actual use range, check the data in the technical data sheet for the combined motors. Up to size 1500 x 1500. Over, in two pieces.

 Open the catalog to page 3
GTE 10-4

Adjusting damper 100 pitch SagiCofim Dimensional Measurements are in (mm)

 Open the catalog to page 4
GTE 10-5

Adjusting damper 100 pitch GTE 10 Manual commands Measurements are in (mm) Automated version Over 1.2 m2 Command weight 0.7 kg • All the manual commands are equipped with a lever locking mechanism in the requested position. • The damper can be equipped with electric motors for the Safe area and the ATEX area, both on / off and modular and with spring return. • The maximum dimensions of the motor without accessories are: BELIMO: X = 80 mm; Y = 250 mm SCHISCHEK X =  100 mm; Y = 210 mm • ON REQUEST Motors assembled inside the a

 Open the catalog to page 5
GTE 10-6

Adjusting damper 100 pitch GTE 10 Diagram 1 - Pressure drop and sound power level Pressure drop referring to sample 1000 x 1010 mm Degrees of damper opening 90°

 Open the catalog to page 6
GTE 10-7

Adjusting damper 100 pitch SagiCofim Tab. 3 Maximum torque (Nm) H B (mm) (mm) 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 NOTE: The torque values, outlined in the table, are intended for correct movement and total closure of the damper. For the dimensions not outlined in the table, refer to the torque values of the immediately larger size. Weights refer to dampers only without commands or motors. B > 1500 : two sections divided by a central separator, one command pin H > 2010 : reinforcement rods mid height

 Open the catalog to page 7
GTE 10-8

Adjusting damper 100 pitch GTE 10 Motor selection guide The values, outlined, of the motor torque are nominal values (i.e. the minimum guaranteed value in all use conditions according to the technical data sheet of the motor). Torque 2 Nm Torque 5 Nm WITHOUT In light operating conditions: a motor can be combined with the damper with a nominal torque 20% lower than the maximum torque required by the damper (see tab. 3). CM 24 SR - L-R; IP 54; VROT = 75 sec LM 24-230 A - SR; IP 54; VROT = 150 sec InMax - 5.10-Y; IP 66; VROT = 7.5 / 15 / 30 / 60 / 120 sec spring return ExMax - 5.10 Y; IP 66; VROT...

 Open the catalog to page 8
GTE 10-9

Adjusting damper 100 pitch LM 24-230 A-S; IP 54; VROT = 150 sec; 1 adjusting contact InMax - 5.10; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec InMax - 5.10-S; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec; 2 fixed contacts spring return SAFE AREA spring return Damper ON - OFF Function spring return NM 24-230 A; IP 54; VROT = 150 sec NM 24-230 A-S; IP 54; VROT = 150 sec; 1 adjusting contact InMax-15.30; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec InMax-15.30-S; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec; 2 fixed contacts SM 24-230 A; IP 54; VROT = 150 sec SM 24-230 A-S; IP 54; VROT = 150 sec; 1 adjusting contact...

 Open the catalog to page 9
GTE 10-10

Adjusting damper 100 pitch GTE 10 Diagram 2 - Casing leakage (Class B) 5 UNI EN 1751 CL B Diagram 3 - Closed damper leakage (Class 2) 210 Pressure (Pa) Sample tests carried out on sizes 1000 x 1010 mm, in our laboratory. Results can be extended to the entire dimensional range of the product (see tab.1 page 4). Instrumentation, measurement and control systems in compliance with Standard EN 1751. Laboratory created in collaboration with the Politecnico di Milano, Engineering Faculty. ISO 9001 and ISO 14001 Certified Company. * Average performance

 Open the catalog to page 10
GTE 10-11

Adjusting damper 100 pitch Comfort Assembly applications • Fastening to duct using M 6 bolts. • Seal between the damper flange and duct. • Do not install in areas subject to stress phenomena, i.e. vibrations, bending or cyclic torsion. • Do not deform or twist the frame during maintenance and installation operations. • Install in areas protected from atmospheric agents. Maintenance • Before any intervention on the product use the planned IPD and then cut power to the command systems. • To clean, use substances or liquids that are NON-acidic and NON-abrasive • Do not paint levers or pins •...

 Open the catalog to page 11
GTE 10-12

SagiCofim spa Comfort Filtration Engineering via Firenze 1 20063 Cernusco sul Naviglio MilanItaly tel +39 02 929021 fax +39 02 92902300 [email protected] www.sagicofim.com Sagicofim S.p.A. reserves the right to make changes or amendments at any time without being obliged to give advance notification in relation to information in this publication.

 Open the catalog to page 12

All SagiCofim catalogs and technical brochures

  1. PV

    2  Pages

  2. INDUL V45

    3  Pages

  3. BPV - VENL0001

    16  Pages

  4. DUG-B -DUG-A

    2  Pages

  5. LBM - KBM

    1  Page

  6. LLB - KK

    1  Page

  7. AB - AA

    3  Pages

  8. LS - KS

    1  Page

  9. DEC A -DEC S

    3  Pages

  10. TAS.OP

    8  Pages

  11. Pharmasafe

    8  Pages

  12. AH - AS

    1  Page

  13. CB-CA

    1  Page

  14. AF 981 I

    1  Page

  15. LT 151

    2  Pages

  16. LT 500

    3  Pages

  17. LT 350

    3  Pages

  18. BE

    2  Pages

  19. WS 400

    1  Page

  20. WT

    2  Pages

  21. EE 400

    2  Pages

  22. ZAR-R

    1  Page

  23. AF 350

    2  Pages

  24. AD 780

    2  Pages

  25. DR 160

    1  Page

  26. CAT-C

    1  Page

  27. SPIN-C

    1  Page

  28. WR

    2  Pages

  29. WR 400

    1  Page

  30. TAB

    4  Pages

  31. ZAR-C

    1  Page

  32. WT 500 S

    1  Page

  33. CC 600

    1  Page

  34. SDFZ

    1  Page

  35. DC 560 T

    1  Page

  36. DC 560 S

    1  Page

  37. DC 570 S

    1  Page

  38. DC 570 T

    1  Page

  39. SDFZ-R

    1  Page

  40. LD 600

    3  Pages

  41. KMF

    8  Pages

  42. RSVC-K

    4  Pages

  43. RSVB

    16  Pages

  44. RSVC

    16  Pages

  45. RSVQ

    12  Pages

  46. VRK

    1  Page

  47. VRRK

    1  Page

  48. GTA 010 EN

    12  Pages

  49. GT 019

    12  Pages

  50. GT 018

    12  Pages

  51. GT 050

    12  Pages

  52. GT 015

    12  Pages

  53. GTE 11

    12  Pages

  54. GTE 05

    12  Pages

  55. GTE 06

    12  Pages

  56. GTE 08

    12  Pages

  57. GTA 010

    12  Pages

  58. GTA 015

    12  Pages

  59. SDL-SDLT

    16  Pages

  60. HTE 400

    14  Pages

  61. SFD-SFDT

    16  Pages

  62. TB-TC

    1  Page

  63. AFO-AL1-AL2

    3  Pages

  64. SA SA - LF

    2  Pages

  65. MCA - MCPA

    4  Pages

  66. RAS

    12  Pages

  67. INER-ST

    8  Pages

  68. AD 300

    2  Pages

  69. GS 130

    1  Page

  70. GF 130

    2  Pages

  71. PDP

    1  Page

  72. MPS

    2  Pages

  73. PK

    3  Pages

  74. JD

    3  Pages

  75. FLG

    2  Pages

  76. PFA/4/5

    1  Page

  77. PFO/E/S/H

    1  Page

  78. PFO/6/7/8/9

    1  Page

  79. CARBO

    1  Page

  80. CANISTER

    4  Pages

  81. Multimod

    1  Page

  82. CAB

    1  Page

  83. Modulo

    1  Page

  84. CT

    1  Page

  85. SAF

    1  Page

  86. CAB - PT

    1  Page

  87. DAB - DAA

    1  Page

  88. ABH - AAH

    1  Page

  89. LLMB - KKMB

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.