GTE 06 Adjusting damper 100 pitch
Open the catalog to page 1Adjusting damper 100 pitch Comfort Use range of the damper: in ATEX version in SAFE area - 20 ° C< t < + 50 ° C - Vmax 15 m/s - Pmax 3000 Pa - 20 ° C < t < + 70 ° C - Vmax 25 m/s - Pmax 3000 Pa Specific features of the product STANDARD version Note: in the ATEX version, the damper is equipped with a a specific label and earthing cable. To establish the actual use range, check the data in the technical data sheet for the combined motors. Up to size 1500 x 1500. Over, in two pieces.
Open the catalog to page 3Adjusting damper 100 pitch SagiCofim Dimensional Measurements are in (mm)
Open the catalog to page 4Adjusting damper 100 pitch SagiCofim Manual commands Measurements are in (mm) C 22 Over 1.2 m2 Command weight 0.7 kg • All the manual commands are equipped with a lever locking mechanism in the requested position. Automated version • The damper can be equipped with electric motors for the Safe area and the ATEX area, both on / off and modular and with spring return. • The maximum dimensions of the motor without accessories are: BELIMO: X = 80 mm; Y = 250 mm • ON REQUEST Motors assembled inside the air flow.
Open the catalog to page 5Adjusting damper 100 pitch GTE 06 Diagram 1 - Pressure drop and sound power level (closed) 0° Pressure drop referring to sample 1000 x 1010 mm Degrees of damper opening 90°
Open the catalog to page 6Adjusting damper 100 pitch SagiCofim Tab. 3 Maximum torque (Nm) H B (mm) NOTE: The torque values, outlined in the table, are intended for correct movement of the damper. For the dimensions not outlined in the table, refer to the torque values of the immediately larger size. Weights refer to dampers only without commands or motors. B > 1500 : two sections divided by a central separator, one command pin H > 2010 : reinforcement rods mid height
Open the catalog to page 7Adjusting damper 100 pitch GTE 06 Motor selection guide Damper GTE 06 can be automated, however to obtain optimal performance of the damper-motor system, we suggest you choose model GTE 05, with the same features and equipped with damper stops. The values, outlined, of the motor torque are nominal values (i.e. the minimum guaranteed value in all use conditions according to the technical data sheet of the motor). In light operating conditions: ν < 2 m/s, t 15 < t < 30 °C, p < 300 Pa a motor can be combined with the damper with a nominal torque 20% lower than the maximum torque required by the...
Open the catalog to page 8Adjusting damper 100 pitch LM 24-230 A-S; IP 54; VROT = 150 sec; 1 adjusting contact InMax - 5.10; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec InMax - 5.10-S; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec; 2 fixed contacts WITHOUT spring return NM 24-230 A; IP 54; VROT = 150 sec NM 24-230 A-S; IP 54; VROT = 150 sec; 1 adjusting contact InMax-15.30; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec InMax-15.30-S; IP 66; VROT = 3 / 15 / 30 / 60 / 120 sec; 2 fixed contacts SM 24-230 A; IP 54; VROT = 150 sec SM 24-230 A-S; IP 54; VROT = 150 sec; 1 adjusting contact SAFE AREA TF 24-230; IP 42; VROT mot = 75 sec; VROT...
Open the catalog to page 9Adjusting damper 100 pitch GTE 06 Diagram 2 - Casing leakage (Class B) 5 UNI EN 1751 CL B Damper leakage test not applicable. Damper NOT equipped with side sealing plates
Open the catalog to page 10Adjusting damper 100 pitch Comfort Assembly applications • Fastening to duct using M 6 bolts. • Seal between the damper flange and duct. • Do not install in areas subject to stress phenomena, i.e. vibrations, bending or cyclic torsion. • Do not deform or twist the frame during maintenance and installation operations. • Install in areas protected from atmospheric agents. Maintenance • Before any intervention on the product use the planned IPD and then cut power to the command systems. • To clean, use substances or liquids that are NON-acidic and NON-abrasive • Do not paint levers or pins •...
Open the catalog to page 11SagiCofim spa Comfort Filtration Engineering via Firenze 1 20063 Cernusco sul Naviglio MilanItaly tel +39 02 929021 fax +39 02 92902300 [email protected] www.sagicofim.com Sagicofim S.p.A. reserves the right to make changes or amendments at any time without being obliged to give advance notification in relation to information in this publication.
Open the catalog to page 122 Pages
3 Pages
16 Pages
2 Pages
1 Page
1 Page
3 Pages
1 Page
1 Page
3 Pages
8 Pages
8 Pages
8 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
1 Page
3 Pages
1 Page
1 Page
2 Pages
1 Page
4 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
3 Pages
8 Pages
2 Pages
2 Pages
4 Pages
16 Pages
16 Pages
12 Pages
1 Page
1 Page
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages
14 Pages
16 Pages
1 Page
3 Pages
2 Pages
4 Pages
7 Pages
12 Pages
8 Pages
2 Pages
1 Page
2 Pages
2 Pages
1 Page
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page