PANTERA AIR SYSTEM
173Pages

{{requestButtons}}

Catalog excerpts

PANTERA AIR SYSTEM - 1

User and maintenance manual Manuel d’utilisation et d’entretien Manuale d’uso e manutenzione Instrukcja obsługi i konserwacji Manual de usuário e manutenção Kullanım ve bakım kılavuzu

Open the catalog to page 1
PANTERA AIR SYSTEM - 2

USER AND MAINTENANCE MANUAL 1.

Open the catalog to page 2
PANTERA AIR SYSTEM - 4

USER AND MAINTENANCE MANUAL 8. 1.

Open the catalog to page 4
PANTERA AIR SYSTEM - 5

DECLARATION OF CONFORMITY http://shop.trafimet.com/it/Dcue-TrafimetGroup-Adf3.html Trafimet Group Spa, a duly registered Italian Manufacturing Company, located in Via del Lavoro, 8 36020 Castegnero (VI), hereby declares that products identified and described on these pages are in conformity with the Regulation: EU 2016/425 and the standards EN 175:1997, EN 379:2009, CSA Z94.3, ANSIZ87.1, EN 12941: 1998 +A1:2003+A2:2008 TH3 R SL BEFORE WELDING Please read carefully the user and maintenance manual before operating. Taking into use and all maintenance work must be implemented and carried out...

Open the catalog to page 5
PANTERA AIR SYSTEM - 6

EN USER AND MAINTENANCE MANUAL Introduction This manual is made of 2 parts: 1 - “PANTERA” AUTODARKENING MASK 2 - COMPLETE “PANTERA AIR SYSTEM” PART 1 - “PANTERA” AUTODARKENING MASK The PANTERA autodarkening welding mask is a new generation welding helmet integrating some of the most innovative technologies such as digital LCD, optoelectronics detection with 4 sensors and very wide viewing area, solar power and litium batteries, microelectronics, and True Color ADF technology. The PANTERA automatic welding mask is equipped with an ADF filter with digital regulations, for an easy and fast...

Open the catalog to page 6
PANTERA AIR SYSTEM - 7

Main specifications PANTERA automatic welding helmet is equipped with an auto-darkening filter with 4 sensors, digital display and a wide view area. Before activation the filter shade is DIN 4, so that the operators may clearly observe the work surface clearly. Once the arc is ignited, the filter darkens automatically. When the arc goes out, the filter will becomes transparent again. The mask is equipped with DIN 9-13 darkness adjusting. The switching time from light to dark is about 0.08 ms. The switching time from dark to light (DELAY) may be set up within 0.10.9 second. The operator can...

Open the catalog to page 7
PANTERA AIR SYSTEM - 8

EN USER AND MAINTENANCE MANUAL 6. Because the shapes of users’ heads vary from person to person. The work position and the observing angle is different, operator may adjust the headband adjusting button 15 and the segmental positioning plate 16 to select an appropriate observing angle. By pushing and turning the adjustment screw 11, the perimeter of the head band can be adjusted. Grind function Press the WELD/GRIND button to choose the Grind option. The grind flash light will flash at the same time. To avoid any harm to eyes, do not conduct welding while on grinding mode. Battery indicator...

Open the catalog to page 8
PANTERA AIR SYSTEM - 9

Recommended shade number according to EN 379 Welding process Covered electrodes Plasma cutting PART 2 - COMPLETE PANTERA AIR SYSTEM Pantera Air System is a combined face and respiratory protection device for increased safety and comfort during welding. Please read these instructions carefully before unpacking. The respiratory protection system must not be used: • In a dangerous environment for the user’s health and safety, an environment with an oxygen level below 17% or containing unknown substances. • In confined or non-ventilated environments such as curves, etc. • Near flames or...

Open the catalog to page 9
PANTERA AIR SYSTEM - 10

EN USER AND MAINTENANCE MANUAL The manufacturer is not responsible for injury due to the following incorrect use or incorrect choice of equipment. Warning: • The respiratory devices should be use with well-trained personal and qualified person only. • Before using the devices ensure you have understood that at very high work rates the pressure in the device may become negative at peak inhalation flow. • Before and during using the devices, attention shall be drawn to possible incorrect use and, where appropriate, the possibility of looped hoses and/or cables becoming caught up. • Before or...

Open the catalog to page 10
PANTERA AIR SYSTEM - 11

Check that correct number of components has been supplied, as in figure 3-1. Check that the apparatus is complete, undamaged and correctly assembled. Any damaged or defective parts must be replaced before use. If any of the above components are not included in your kit, please contact the supplier immediately. Remove the filter cover by pressing in the latch of the filter cover. The filter cover is released. Remove the used filter by lifting it out from the filter cover. Remove the used filter by lifting it out from the filter cover. 4. Remove the pre-filter. 5. If the filtration grill is...

Open the catalog to page 11
PANTERA AIR SYSTEM - 12

EN USER AND MAINTENANCE MANUAL 7. Put the buckle back. 8. Attach the harness to the belt’s 4 plastic rings. Make sure the belt is securely fastened. 1. Connect the air tube to the respiratory system and twist it clockwise to lock its position. 2. Connect the other end of the tube to the headgear in the same way. 1. Check that the respiratory tube is strongly connected. If the tube is broken, replace it. All components must be installed/ used in accordance with this manual if the equipment is to offer the specified protection. If any component is missing, or if anything is not clear, contact...

Open the catalog to page 12
PANTERA AIR SYSTEM - 13

There is a LCD display screen on Pantera Air System to show the working system condition. Part 1  shows the data of current air flow. Part 2  shows the level of the airflow. Part 3  shows the filter condition. Part 4  shows the battery. Part 5  shows the temperature of the battery. Any of them will flash if there are any disfunctions on Pantera Air System. Operation Switch the device on by pressing the ON button once. x1 Press the ON button once again, the air flow is at level 1 (~170L/min). x2 Press the ON button once again, the air flow is at level 2 (~200L/min). x3 x4 1. 2. 3. Press the...

Open the catalog to page 13
PANTERA AIR SYSTEM - 14

EN USER AND MAINTENANCE MANUAL 5. MAINTENANCE & STORAGE The Pantera Air System must be checked regularly and must be changed if it is damaged and cause leakage. The filter must be changed if it is broken, or it is blocked and does not give enough airflow. The breathing tube must be changed if it is broken or has crevasse. The battery must be charged when the low battery alarm rings. Use a soft cloth to wipe the external surfaces. Don’t use water! The filter should be replaced together with the pre-filter. The Pantera Air System must be stored in a dry, clean area, in the temperature range...

Open the catalog to page 14

All SACIT catalogs and technical brochures