Besilen® - Silicone Cables
Open the catalog to page 1Besilen® cables acc. to VDE, UL, cUL and CSA Besilen® sheathed cables acc. to UL and CSA Besilen® insulated strands with Besilen® outer sheath Besilen® insulated strands with overall copper screen and Besilen® outer sheath Besilen® insulated strands with Besilen® outer sheath and steel wire armouring for mechanical protection Besilen® sheathed cables acc. to UL and cUL SC 700 HDTR Besilen® insulated strands with Besilen® outer sheath SC 700 C HDTR Besilen® insulated strands with overall copper screen and Besilen® outer sheath Besilen® single conductors acc. to DIN VDE 0250 part 502 N2GFA/2GFA...
Open the catalog to page 3Besilen - Silicone Cables ® Applications of Beesilen® cables Our Besilen® (Silicone) cables are suitable for diverse applications. The product programme ranges from ignition cables to sheathed cables with mechanical protection and cables with flame protection. Therefore, Besilen® cables can be used for example in the following industries: coke oven plants, foundries, heating appliances, smelteries, steelworks, hot-rolling mills, illumination, in ships and aeroplanes, cement, glass and ceramic factories, bakeries, oil burners, solariums, saunas, coolers, air-conditioning, electronic motor engineering...
Open the catalog to page 4Besilen - Silicone Cables ® Applications of Besilen® sheathed cables Our Besilen® sheathed cables are suitable for applications at high ambient temperatures in dry, damp and wet rooms as well as for outdoor use, as flexible connection cable with low mechanical load. The mechanical load capacity can be enhanced by using a steel wire armouring, a fibre-glass braiding or an inner sheath. The EMC characteristics can be improved by use of an overall copper screen. If these cables are used for fixed installation, they are only to be installed in ventilated tube systems or conduits. If hermetically...
Open the catalog to page 5Besilen - Silicone Cables ® Special features Temperature range fixed laying* from F = flexible · H = highly flexible 5 mm ø · 2 7 mm ø · 3 to 6,0 mm² · 4 form 10,0 mm² · 5 at conductor *The temperature range for flexible application is mentioned on the corresponding catalogue page Twin cable Ignition cable Single conductor for tube lamps Single conductor Solid wire Copper rope Multi conductor cable Screen Fibre-glass braiding Steel wire braiding +250 °C +180 °C +105 °C + 90 °C – 40 °C – 50 °C Nominal voltage 24 V Nominal voltage Uo/U 300/300 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U...
Open the catalog to page 6Besilen - Silicone Cables ® Special features Temperature range fixed laying* from BiHF/Cu/Bi-J / BiHF/Cu/Bi(K)-J Besilen® ESD Control Cable BiHF-J /BiHF(K)-J Twin cable Ignition cable Single conductor for tube lamps Single conductor Solid wire Copper rope Multi conductor cable Screen Fibre-glass braiding Steel wire braiding +250 °C +180 °C +105 °C + 90 °C – 40 °C – 50 °C Nominal voltage 24 V Nominal voltage Uo/U 300/300 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 0,6/1 kV Nominal voltage Uo/U 1,5/1,5 kV Nominal voltage Uo/U 1,8/3 kV Nominal voltage Uo/U 3,6/6 kV Nominal voltage Uo/U...
Open the catalog to page 7Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » PFAS free Technical data Dielectric voltage: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Corrosiveness of conflagration gases: Chem. resistance: Absence of harmful substances: IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases see chapter N ..Technical data” acc. to RoHS directive of the European Union, see chapter N .Technical data”
Open the catalog to page 8Besilen® twin cable FREE Technical data: Nominal voltage: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: Construction: Conductor: tinned copper strands, Sheath colour: reddish brown (similar RAL 3016) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » PFAS free flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 IEC 60754-2 +...
Open the catalog to page 9Besilen® ignition cable Construction: Conductor: tinned copper strands, Braiding: fibre-glass Sheath material: Besilen® 2GM1 Sheath colour: blue (similar RAL 5012) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » voltage-stable » PFAS free Technical data: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: flame retardant and self-extinguishing acc. to - no...
Open the catalog to page 10Besilen® high-voltage ignition cable RoWf Construction: Conductor: tinned copper strands 19 x 0,25 mm 0 acc. to EN 50363-1 + VDE 0207-363-1 Sheath colour: reddish brown (similar RAL 3016) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » voltage-stable » PFAS free Technical data: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: flame retardant and self-extinguishing...
Open the catalog to page 11Besilen® insulated single conductor for tube lamps (neon cable) Technical data: Nominal voltage: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: Construction: Conductor: tinned copper strands, Sheath colour: yellow (similar RAL 1006) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » neon coloured » PFAS free flame retardant and self-extinguishing acc. to...
Open the catalog to page 1216 Pages
63 Pages
16 Pages
12 Pages
8 Pages
22 Pages
27 Pages
22 Pages
36 Pages
19 Pages
12 Pages
32 Pages
28 Pages
12 Pages
16 Pages
12 Pages
8 Pages
28 Pages
44 Pages
20 Pages
36 Pages
20 Pages