1. Catalogs
  2. SAB BROECKSKES GMBH & Co. KG
  3. Silicone Cables | Temperature Resistant

Silicone Cables | Temperature Resistant

Silicone Cables | Temperature Resistant
1 / 41 PagesView full catalog

Silicone Cables | Temperature Resistant

Product catalog summary
Overview: The document provides comprehensive details on Besilen® silicone cables, emphasizing their industrial applications, specifications, and technical data. These cables are renowned for their resistance to extreme temperatures, making them ideal for various industrial settings.
Applications: Besilen® cables are utilized in industries such as coke oven plants, foundries, heating appliances, and steelworks. They are suitable for high-temperature environments and are used in internal wiring of lamps, appliances, and switchboards. Specific applications include ignition cables for high temperatures, single conductors for rail vehicles, and ESD control cables to prevent electrostatic discharge.
Specifications: The document includes selection tables detailing the types of Besilen® cables, their temperature ranges, nominal voltages, and testing voltages. Key features include halogen-free construction, flexibility at low temperatures, heat resistance, and compliance with standards such as IEC and VDE.
Technical Data: Besilen® cables are characterized by their dielectric voltage, radiation resistance, and temperature range for both fixed and flexible applications. They are flame retardant, self-extinguishing, and resistant to corrosive conflagration gases. The cables are also PFAS free and comply with the RoHS directive.
Construction Details: The cables are constructed with tinned copper strands and Besilen® insulation. Some variants include fibre-glass braiding for additional protection. The document specifies the sheath materials and colors for different cable types.
Key Features: Besilen® cables offer excellent weather resistance, good oil resistance, and protection against mechanical damage. They are suitable for both indoor and outdoor use, with options for enhanced mechanical load capacity through steel wire armouring or copper screening.
Technical Specifications:
  • Nominal Voltage: Uo/U 300/500 V
  • Testing Voltage: Core/Core 2000 V
  • Minimum Bending Radius: Fixed Laying: 4 x d, Flexible Application: 6 x d
  • Temperature Range: Fixed Laying: -40/+180 °C, Flexible Application: -25/+180 °C, Short-time Use: +250 °C
  • Radiation Resistance: 2 x 107 cJ/kg
  • Halogen-Free: According to IEC 60754-1 + VDE 0482-754-1
  • Fire Performance: Flame retardant and self-extinguishing according to IEC 60332-1-2 + VDE 0482-332-1-2
  • Corrosiveness of Conflagration Gases: No development of corrosive gases according to IEC 60754-2 + VDE 0482-754-2
  • Chemical Resistance: Refer to chapter N "Technical data"
  • Weather Resistance: Very good
  • Absence of Harmful Substances: Compliant with RoHS directive of the European Union
Construction Details:
  • Conductor: Tinned copper strands according to IEC 60228, VDE 0295, class 5
  • Insulation: Besilen® EI2 according to EN 50363-1 + VDE 0207-363-1
  • Colour Code: Coloured according to HD 308 (VDE 0293-308), with black cores and consecutive numbers from 6 cores, and a green-yellow earth wire from 3 cores
  • Stranding: In layers
  • Sheath Material: Besilen® notch resistant
  • Sheath Colour: Black (similar RAL 9011)
Product Features:
  • Improved initial tear resistance
  • Improved tear-growth resistance
  • Extremely notch resistant
  • Good sunlight resistance
  • Halogen-free
  • Flexible at low temperatures
  • Heat resistant
  • PFAS free
Product Variants:
  • BiHF(K)-J: Besilen® insulated strands with extremely notch resistant Besilen® outer sheath
  • BiHFP-J: Besilen® insulated strands with Besilen® outer sheath and steel wire armouring for mechanical protection
  • BiHFGLP-J: Besilen® insulated strands with Besilen® outer sheath, fibre-glass tape, and steel wire armouring for mechanical protection
  • BiAF/Cu/Bi-J: Besilen® insulated strands with Besilen® outer sheath and overall copper screen
Key Data from Tables: The tables provide detailed specifications for various cable configurations, including the number of cores, cross-section, outer diameter, copper weight, and overall cable weight. These specifications are crucial for selecting the appropriate cable for specific applications based on electrical and mechanical requirements.
See more

Catalog excerpts

Silicone Cables | Temperature Resistant-1

Besilen® - Silicone Cables

 Open the catalog to page 1
Silicone Cables | Temperature Resistant-3

Besilen® cables acc. to VDE, UL, cUL and CSA Besilen® sheathed cables acc. to UL and CSA Besilen® insulated strands with Besilen® outer sheath Besilen® insulated strands with overall copper screen and Besilen® outer sheath Besilen® insulated strands with Besilen® outer sheath and steel wire armouring for mechanical protection Besilen® sheathed cables acc. to UL and cUL SC 700 HDTR Besilen® insulated strands with Besilen® outer sheath SC 700 C HDTR Besilen® insulated strands with overall copper screen and Besilen® outer sheath Besilen® single conductors acc. to DIN VDE 0250 part 502 N2GFA/2GFA...

 Open the catalog to page 3
Silicone Cables | Temperature Resistant-4

Besilen - Silicone Cables ® Applications of Beesilen® cables Our Besilen® (Silicone) cables are suitable for diverse applications. The product programme ranges from ignition cables to sheathed cables with mechanical protection and cables with flame protection. Therefore, Besilen® cables can be used for example in the following industries: coke oven plants, foundries, heating appliances, smelteries, steelworks, hot-rolling mills, illumination, in ships and aeroplanes, cement, glass and ceramic factories, bakeries, oil burners, solariums, saunas, coolers, air-conditioning, electronic motor engineering...

 Open the catalog to page 4
Silicone Cables | Temperature Resistant-5

Besilen - Silicone Cables ® Applications of Besilen® sheathed cables Our Besilen® sheathed cables are suitable for applications at high ambient temperatures in dry, damp and wet rooms as well as for outdoor use, as flexible connection cable with low mechanical load. The mechanical load capacity can be enhanced by using a steel wire armouring, a fibre-glass braiding or an inner sheath. The EMC characteristics can be improved by use of an overall copper screen. If these cables are used for fixed installation, they are only to be installed in ventilated tube systems or conduits. If hermetically...

 Open the catalog to page 5
Silicone Cables | Temperature Resistant-6

Besilen - Silicone Cables ® Special features Voltage from F = flexible · H = highly flexible 5 mm ø · 2 7 mm ø · 3 to 6,0 mm² · 4 from 10,0 mm² · 5 at conductor *The temperature range for flexible application is mentioned on the corresponding catalogue page Twin cable Ignition cable Single conductor for tube lamps Single conductor Solid wire Copper rope Multi conductor cable Screen Fibre-glass braiding Steel wire braiding +250 °C +180 °C +105 °C + 90 °C – 40 °C – 50 °C Nominal voltage 24 V Nominal voltage Uo/U 300/300 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 0,6/1 kV Nominal voltage...

 Open the catalog to page 6
Silicone Cables | Temperature Resistant-7

Besilen - Silicone Cables ® Special features Temperature range fixed laying* from BiHF/Cu/Bi-J / BiHF/Cu/Bi(K)-J Besilen® ESD Control Cable BiHF-J /BiHF(K)-J Twin cable Ignition cable Single conductor for tube lamps Single conductor Solid wire Copper rope Multi conductor cable Screen Fibre-glass braiding Steel wire braiding +250 °C +180 °C +105 °C + 90 °C – 40 °C – 50 °C Nominal voltage 24 V Nominal voltage Uo/U 300/300 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 0,6/1 kV Nominal voltage Uo/U 1,5/1,5 kV Nominal voltage Uo/U 1,8/3 kV Nominal voltage Uo/U 3,6/6 kV Nominal voltage Uo/U...

 Open the catalog to page 7
Silicone Cables | Temperature Resistant-8

Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » PFAS free Technical data Dielectric voltage: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Corrosiveness of conflagration gases: Chem. resistance: Absence of harmful substances: IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases see chapter N ..Technical data” acc. to RoHS directive of the European Union, see chapter N .Technical data”

 Open the catalog to page 8
Silicone Cables | Temperature Resistant-9

Besilen® twin cable FREE Technical data: Nominal voltage: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: Construction: Conductor: tinned copper strands, Sheath colour: reddish brown (similar RAL 3016) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » PFAS free flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 IEC 60754-2 +...

 Open the catalog to page 9
Silicone Cables | Temperature Resistant-10

Besilen® ignition cable Construction: Conductor: tinned copper strands, Braiding: fibre-glass Sheath material: Besilen® 2GM1 Sheath colour: blue (similar RAL 5012) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » voltage-stable » PFAS free Technical data: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: flame retardant and self-extinguishing acc. to - no...

 Open the catalog to page 10
Silicone Cables | Temperature Resistant-11

Besilen® high-voltage ignition cable RoWf Construction: Conductor: tinned copper strands 19 x 0,25 mm 0 acc. to EN 50363-1 + VDE 0207-363-1 Sheath colour: reddish brown (similar RAL 3016) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » voltage-stable » PFAS free Technical data: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: flame retardant and self-extinguishing...

 Open the catalog to page 11
Silicone Cables | Temperature Resistant-12

Besilen® insulated single conductor for tube lamps (neon cable) Technical data: Nominal voltage: Testing voltage: Min. bending radius: Radiation resistance: Temperature range fixed laying: flexible application: short time use: Fire performance: Corrosiveness of conflagration gases: Chem. resistance: Weather resistance: Absence of harmful substances: Construction: Conductor: tinned copper strands, Sheath colour: yellow (similar RAL 1006) Outstanding features: » halogen-free » flexible at low temperatures » heat resistant » neon coloured » PFAS free flame retardant and self-extinguishing acc. to...

 Open the catalog to page 12

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Dynamic Cables

    30  Pages

  2. Data Cables

    22  Pages

  3. Tray Cables

    19  Pages

  4. Tactical Cables

    12  Pages

  5. Reeling Cables

    16  Pages

  6. Special cables

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.