Servo Motor Cables
Open the catalog to page 1Servo Motor CablesContent page
Open the catalog to page 2Servo Motor Cables Applications Applications motor connection cables for pulse converter fed three-phase drives These cables are suitable for the fixed installation and flexible use e.g. in machine and industrial plant construction with average mechanical demand in dry, damp and wet conditions. Applications motor feedback and transmission cables Feedback cables are used for controlling motor speed and for giving feedback values. Transmission cables produce transmit control pulses for positioning and procedure characteristics. Exemplary applications: Highly flexible, mobile connection cables for...
Open the catalog to page 3Servo Motor Cables Applications Applications of Tray Cable (UL 1277) and Machine-Tool Cable (UL 1063) In industrial electrical installations, robust, standardcompliant cables are essential for safe and efficient power and control current supply. Common cable types include tray cable (TC), machine tool wire (MTW), wind turbine tray cable (WTTC) and STOOW cables. These cables are classified according to various UL standards and designed for different operating conditions. Tray Cable (TC) acc. to UL 1277 Type TC refers to cables that are approved for permanent installation in cable trays, ducts...
Open the catalog to page 4Servo Motor Cables testing voltage 3000 V testing voltage 4000 V peak operating voltage max. 350 V peak operating voltage max. 500 V transmission and feedback cable motor connection cable screen temperature applirange fixed laying* cation cable type Selection table fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 fire performance: acc. to cUL FT1, FT2 cUL recognized CSA approval DESINA® colours PFAS free PWIS uncritical** outer sheath surface: low adhesion very good oil resistance acc. to EN 50363-10-2 + VDE 0207-363-10-2 good resistance against...
Open the catalog to page 5c variable frequency drive cable UL motor connection cable voltage (UL) / c(UL) 600 V voltage CSA-AWM / (UL) WTTC 1000 V J voltage (UL) 2000 V testing voltage 3000 V testing voltage 7500 V fire performance: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 -2 fire performance: (UL) FT4 / IEEE 1202 (UL) recognized ■2 c(UL)us recognized CSA approval NFPA 79 WTTC approval UL 90°C wet WTTC: UL subject 2277 TC-ER: UL standard 1277 Class 1 Div 2 per NEC Article 501.4 (B) IEEE 1202/FT4 2 PFAS free sunlight resistance exposed runs cold bend test -40 °C direct burial moisture resistance
Open the catalog to page 6low capacity PUR motor connection cable with overall copper screen 0.6/1 kV marking example: Technical data: Testing voltage: core/core 4000 V Temperature range DIN VDE UL/CSA: up to +80 °C Fire performance: flame retardant and self-extinguishing Oil resistance: very good - TMPU Chem. resistance: good against acids, alkalines, solvents, Absence of acc. to RoHS directive of the European Union, harmful substances: see chapter N „Technical data” Construction: Conductor: bare copper strands Insulation: special polymer Colour code: black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334...
Open the catalog to page 7Servo Motor CablesSL 835 C symmetrical PUR motor connection cable with optimized EMC characteristics 0.6/1 kV marking example: SOB BROCKSKES ■ D-VIERSEN ■ 0835-0315 SL 835 C 3x1,5mm2+3G0,25mm2 cUus AWM Style 21223 I/II A/B 80°C 1000V FT1 FT2 E172204 C Oil resistance: very good - TMPU Chem. resistance: good against acids, alkalines, solvents, Weather resistance: very good Absence of acc. to RoHS directive of the European Union, harmful substances: see chapter N „Technical data” Construction: Conductor: bare copper strands Insulation: special polymer Colour code: black cores with consecutive numbers...
Open the catalog to page 8Servo Motor CablesSL 851 C - ExplorationPUR motor connection cable with overall copper screen 0.6/1 kV Application: Motor connection cable for the electrical hook-up of drilling equipment, compressors, generators as well as pumps in rough environments. Conductor bare copper strands Insulation: SfiBIX” Colour code: coloured acc. to HD 308 (VDE 0293-308) and a green-yellow earth wire Screen: alu foil and tinned copper braiding Wrapping: non-woven tape Sheath material: PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 Sheath colour: black (RAL 9005) Outstanding features: » UL/cUL recognized »...
Open the catalog to page 9low capacity PUR incremental encoder and feedback cable with overall copper screen marking example: SAB BROCKSKES • D-ViERSEN • 0893-0003 SL 893 C 5x2x0,25mm2+2x0,50 mm2DE5IMA cTOus AWM Style 20233 I/ll A/B 80°C 300V FT1 FT2 C€ Construction: Conductor: bare copper strands with reference to Insulation: special polymer Colour code: coloured Stranding: cores/pairs twisted together in layer Screen: wrapped with tinned copper braiding Inner Sheath: special polymer Wrapping: non-woven tape or foil Screen: tinned copper braiding Wrapping: non-woven tape or foil Sheath material: PUR Sheath colour: green...
Open the catalog to page 10Servo Motor CablesSL 875 C low capacity PUR hybrid motor connection cable with overall copper screen 0.6/1 kV ««“ FREE marking example: Technical Data: Conductor: bare copper strands acc. to IEC 60228, VDE 0295, class 6 < 0,50 mm2 with reference to VDE 0812 Insulation: special polymer Colour code: item 087501 . . supply cores: black cores with printing and a green-yellow earth wire control cores: black cores with number 5+6 feedback: white, blue supply cores: black, blue, brown, green-yellow control cores: white-blue, white-green feedback: white-green, brown-green + grey, pink, yellow, violet...
Open the catalog to page 11Servo Motor CablesSL 891 C low capacity combined PUR motor connection cable with overall copper screen 0.6/1 kV marking example: SOB BROCKSKES ■ D-VIERSEN ■ 0891-1415 SL 891 C 4x1,5mm2+(2x1,5mm2) cUus AWM Style 21223 I/II A/B 80°C 1000V FT1 FT2 E172204 C Chem. resistance: good against acids, alkalines, solvents, Weather resistance: very good Absence of acc. to RoHS directive of the European Union, harmful substances: see chapter N „Technical data” Conductor: bare copper strands Insulation: SfiBIX” Colour code: Bosch Rexroth supply cores: black, number coded 1-3 and a green-yellow earth wire,...