Group: SAB Bröckskes

Catalog excerpts

ETFE, FEP, PFA Cables Content page Applicationse Selection tables Insulated stranded hook-up wires with extended temperature range ■ ■ ■ ■ ■ ■ ■ bare copper strands with UL recognition . . . . . . . . . . . . . . tinned copper strands with UL recognition . . . . . . . . . . . . . nickel-plated copper strands with UL recognition . . . . . . . bare copper strands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bare copper strands with UL recognition . . . . . . . . . . . . . . tinned copper strands with UL recognition . . . . . . . . . . . . . nickel-plated copper strands with...
Open the catalog to page 2
ETFE, FEP, PFA Cables Applications ■ Applications ETFE cables These cables are used for example in news technologies if high demands for resistance against chemicals and solvents must be fulfilled. Further advantages are the low and high temperature resistance as well as the good electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics. Exemplary applications: Li7Ybl Applications in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical...
Open the catalog to page 3
Cable type Basic construction Data cable PFA cable Single conductor ETFE cable FEP cable Selection table Connection cable Copper strands acc. to ASTM B 286 Copper strands acc. to IEC 60228, VDE 0295, class 5 Colour code with reference to DIN 47100 Colour code acc. to HD 308 Colour code acc. to EN 50334 + VDE 0293-334 Twisted pairs Temperature range fixed laying* +260 °C +250 °C +200 °C +180 °C +150 °C +135 °C – 90 °C Peak operating voltage max. 375 V Peak operating voltage max. 900 V Voltage Nominal voltage Uo/U 300/500 V Voltage UL 600 V Voltage cUL 600 V Testing voltage 2000 V Testing...
Open the catalog to page 4
ETFE, FEP, PFA Cables FEP and PFA insulated stranded hook-up wire Li6Ybl, Li6Yvz, LiPFAvn - with extended temperature range Construction: Conductor: Technical data: bare, tinned or nickel-plated copper strands acc. to ASTM B 286 Testing voltage: for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands Radiation resistance: excellent resistance against chemicals and solvents Temperature range fixed laying: flexible application: limited time of use: excellent temperature resistance and flexibility at low temperatures Fire performance:...
Open the catalog to page 5
ETFE, FEP, PFA Cables ETFE, FEP and PFA insulated stranded hook-up wire Li7Ybl, Li6Ybl, Li6Yvz, LiPFAvn - with extended temperature range C Construction: Conductor: Technical data: Peak operating voltage: Testing voltage: Temperature range fixed laying: flexible application: limited time of use: high resistance against chemicals and solvents for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands Radiation resistance: Outstanding features: bare, tinned or nickel-plated copper strands acc. to ASTM B 286 low and high temperature...
Open the catalog to page 6
ETFE, FEP, PFA Cables TD 801 F FEP data cable with extended temperature range TD 801 F AWG 22/3c cx AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3801-0322 C Marking for TD 801 F 38010322: S BRÖCKSKES · D-VIERSEN · TD 801 F AWG 22/3c cx AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3801-0322 C Technical data: tinned copper strands acc. to ASTM B 286 Peak operating voltage: Voltage UL/cUL: Colour code: Testing voltage: Sheath material: Radiation resistance: Sheath colour: Temperature range fixed laying: flexible application: limited time of use: Fire performance: flame retardant and...
Open the catalog to page 7
ETFE, FEP, PFA Cables TD 833 CF FEP data cable with extended temperature range and overall copper screen AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3833-0320 C Marking for TD 833 CF 38330320: S BRÖCKSKES · D-VIERSEN · TD 833 CF AWG 20/3c cxus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3833-0320 C Technical data: tinned copper strands acc. to ASTM B 286 Peak operating voltage: Voltage: UL/cUL: Colour code: Testing voltage: PETP foil tinned copper braiding Radiation resistance: Sheath material: Sheath colour: Temperature range fixed laying: flexible application: limited time of use: Fire...
Open the catalog to page 8
ETFE, FEP, PFA Cables TD 838 CF TP FEP data cable, twisted pairs with extended temperature range and overall copper screen 26/3pr cxus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3838-0326 C Marking for TD 838 CF TP 38380326: S BRÖCKSKES · D-VIERSEN · TD 838 CF TP AWG 26/3pr cxus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3838-0326 C Technical data: tinned copper strands acc. to ASTM B 286 Peak operating voltage: Voltage: UL/cUL: Colour code: Testing voltage: cores twisted to pairs, pairs together in specially adjusted layering Radiation resistance: tinned copper braiding Sheath material:...
Open the catalog to page 9
ETFE, FEP, PFA Cables TA 866 F FEP connection cable with extended temperature range AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3866-0415 C Marking for TA 866 F 38660415: S BRÖCKSKES · D-VIERSEN · TA 866 F AWG 16/4c cxus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3866-0415 C Construction: Conductor: Technical data: tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Nominal voltage: Voltage: UL/cUL: Colour code: coloured acc. to HD 308 (VDE 0293-308), from 6 cores black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334, from 3 cores a green-yellow earth wire Testing...
Open the catalog to page 10
ETFE, FEP, PFA Cables TA 867 CF FEP connection cable with extended temperature range and overall copper screen AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3867-0415 C Marking for TA 867 CF 38670415: S BRÖCKSKES · D-VIERSEN · TA 867 CF AWG 16/4c cxus AWM Style 21618 I/II A/B 150°C 600V FT1 FT2 3867-0415 C Construction: Conductor: Technical data: tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Peak operating voltage: Voltage: UL/cUL: Colour code: coloured acc. to HD 308 (VDE 0293-308), from 6 cores black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334, from 3 cores a...
Open the catalog to page 11All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures
-
Halogen-free Cables
64 Pages
-
Harnessed Ethernet Cables
12 Pages
-
Special Cable Manufacturer
20 Pages
-
Cleanroom Cables
12 Pages
-
CONTACT TEMPERATURE MEASUREMENT
16 Pages
-
Cables for wind power plant
28 Pages
-
Reeling Cables
16 Pages
-
Handling Cables
40 Pages
-
Flexible Cables C1
20 Pages
-
High-Temperature Cables & Wires
44 Pages
-
TC 301
1 Pages
-
MTC 205
1 Pages
-
MTC 204
1 Pages
-
MTC 203
1 Pages
-
MTC 201
1 Pages
-
Lift Control Cables
12 Pages
-
Torsion cables
8 Pages
-
Harnessed Cables - Asseblies
36 Pages
-
Cables for Sensors
8 Pages
-
Cables for Airport Equipment
20 Pages
-
USB 2.0/3.0 Cables
12 Pages
-
Cable Asseblies
36 Pages
-
Cables for Railway Technology
32 Pages
-
Servo Motor Cables
23 Pages
-
Tray Cables
21 Pages
-
Cable track cables
51 Pages
-
Drag Chain Cables
51 Pages
-
Data Cables
22 Pages
-
Hybrid and Special Cables
31 Pages
-
SABmed Line
1 Pages
-
Profinet cable
1 Pages
-
Temperature Measurement
12 Pages
-
Heat Resistant Cable
1 Pages
-
SABIX A 147 FRNC
1 Pages
-
CA 156 FRNC
1 Pages
-
Cord Grips
26 Pages