Halogen-free Cables
64Pages

{{requestButtons}}

Catalog excerpts

Halogen-free Cables - 2

Halogen-free Cables Content page Applications Selection tables Halogen-free single conductors ■ A A 146 FRNC wiring cable with improved fire performance and extended temperature range 300/500 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wiring cable with improved fire performance and extended temperature range 450/750 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wiring cable with improved fire performance and extended temperature range 0.6/1 kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . high temperature resistant single conductor with...

Open the catalog to page 2
Halogen-free Cables - 3

Halogen-free Cables Content page Halogen-free data cables ■ A D 305 FRNC flexible data cable with improved fire performance and extended temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . flexible data cable with improved fire performance, extended temperature range and overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . flexible data cable with improved fire performance, extended temperature range and overall copper screen acc. to NF C32-070 C1 . . . . . . . . . . paired data cable with...

Open the catalog to page 3
Halogen-free Cables - 4

Halogen-free Cables Content page L BL-Line - Cables for marine use A BL-Line Data ■ A BL 405 FRNC L BL-Line Data - flexible data cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L BL-Line Data - flexible data cable with overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L BL-Line Data - flexible data cable, twisted triple with overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L BL-Line Data - flexible paired data cable with overall copper screen . . . . . . ....

Open the catalog to page 4
Halogen-free Cables - 5

Halogen-free Cables Applications ■ Application of halogen-free C single conductors and wiring cables These single conductors are installed in applications where high flexibility halogen-free cables are required. The various versions of these cables offer excellent characteristics such as oil resistance, low temperature flexibility, heat resistance, hot-air resistance, weather resistance, being halogen-free. Exemplary applications: C A 146 FRNC C A 156 FRNC C A 166 FRNC C A 147 FRNC C A 157 FRNC Production of control cabinets, appliances and devices for communication technologies, household...

Open the catalog to page 5
Halogen-free Cables - 6

Halogen-free Cables Applications ■ Application of halogen-free C data cables Data cables are used for the transmission of signals, measuring values and control signals in electronic control appliances, data processing systems, railway technologies, weighing installations, office appliances or wherever smallest cross sections, bending radii, shielding or high flexibility is demanded. The excellent characteristics of these cables, in various versions are oil resistance, low temperature flexibility, heat resistance, weather resistance, flexibility, being halogen-free. Exemplary applications:...

Open the catalog to page 6
Halogen-free Cables - 7

Halogen-free Cables Basic construction Single conductors Cable type Selection table screened coloured cores numbered cores twisted pairs Temperature range fixed laying* Inner sheath +220 °C + 90 °C + 85 °C – 30 °C – 40 °C – 50 °C Peak operating voltage max. 350 V Peak operating voltage max. 500 V Nominal voltage Uo/U 300/500 V Testing voltage 1500 V Testing voltage 2000 V Testing voltage 4000 V Halogen-free acc. to IEC 60754-1 + VDE 0482-754-1 Fire performance: Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Fire performance: No flame propagation acc. to IEC...

Open the catalog to page 7
Halogen-free Cables - 8

Halogen-free Cables Cable type Selection table Basic construction Single conductors screened numbered cores twisted pairs Inner sheath Temperature range fixed laying* coloured cores +220 °C + 90 °C + 85 °C – 30 °C – 40 °C – 50 °C Peak operating voltage max. 350 V Peak operating voltage max. 500 V Voltage UL resp. CSA 1000 V Testing voltage 1500 V Testing voltage 2000 V Testing voltage 2500 V Testing voltage 3000 V Corrosiveness of conflagration gases: In compliance with IEC 60754-2 + VDE 0482-754-2 no development of corrosive conflagration gases Testing voltage 4000 V Halogen-free acc. to...

Open the catalog to page 8
Halogen-free Cables - 9

Halogen-free Cables Selection table Temperature range fixed laying* from Fire performance Single conductor Multi-core cable screened Wiring cable Data cable Control cable cross linked type geprüft nach EN 45545-2 acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to IEC 60754-1. pH-value is > 4,3 acc. to IEC 60754-2. Conductivity is < 10,0 μS/mm acc. to IEC 60754-2. Fluoric content < 0,1% acc. to IEC 60684-2 No flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2. Flame...

Open the catalog to page 9
Halogen-free Cables - 10

Halogen-free Cables Selection index Voltage range Temperature range fixed laying* Type approvals Characte- flexible conductor stranding ristics extended cross section range from Data cable Control cable Power cable screened twisted pairs twisted triple + 90°C – 40°C Peak operating voltage max. 300 V Peak operating voltage max. 350 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 0,6/1 kV Testing voltage 1500 V Testing voltage 2000 V Testing voltage 4000 kV Halogen-free acc. to IEC 60754-1 + VDE 0482-754-1 Fire performance: No flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22...

Open the catalog to page 10
Halogen-free Cables - 11

Halogen-free Cables Selection index Control cable screened twisted pairs + 90 °C – 40 °C Peak operating voltage < 0,25 mm² = max. 350 V ≥ 0,25 mm² = max. 500 V No flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25 cat. C resp. D Voltage range Data cable Cable type Construction Temperature range fixed laying* continuously flexible with highest fire protection Flame retardant and self-extinguishing acc. to IEC 60332-1-2, VDE 0482-332-1-2 + NF C 32-070 C1 Corrosiveness of conflagration gases: In compliance with IEC 60754-2 + VDE 0482-754-2 no...

Open the catalog to page 11

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Reeling Cables

    16 Pages

  2. TC 301

    1 Pages

  3. MTC 205

    1 Pages

  4. MTC 204

    1 Pages

  5. MTC 203

    1 Pages

  6. MTC 201

    1 Pages

  7. Tray Cables

    21 Pages

  8. Data Cables

    22 Pages

  9. SABmed Line

    1 Pages

  10. CA 156 FRNC

    1 Pages

  11. Cord Grips

    26 Pages