Data Cables

Data Cables
1 / 22 PagesView full catalog

Data Cables

Product catalog summary
Overview: The document provides comprehensive specifications and applications for SAB's data cables, including PVC data cables, semi-rigid PVC data cables, FEP insulated coaxial cables, and sensor cables. It highlights their construction, technical data, and suitable applications.
Applications: SAB data cables are designed for modern electronics requiring small cross-sections, high flexibility, and effective interference screening. They are used in electronic control appliances, data processing systems, and intercom systems, suitable for indoor use in dry, damp, and wet environments but not for outdoor use.
PVC Data Cables: These include LiYY, LiYY TP, LiYCY, and others, known for flexibility, small outer diameter, and PFAS-free construction. Suitable for fixed installations and flexible applications without tensile load.
Semi-Rigid PVC Data Cables: Cables like SRY D 311 and DC 300 DS offer enhanced mechanical protection and reduced interference.
FEP Insulated Coaxial Cables: RG 179 and RG 316 are noted for high-temperature and chemical resistance, suitable for signal transmission with minimal attenuation and distortion.
Sensor Cables: Designed for extreme temperatures, these cables are suitable for polar or hot regions, offering high flexibility and robustness for temperature measurement and testing.
Technical Specifications: Detailed tables list cable types, construction details, temperature ranges, voltage ratings, and compliance with standards like VDE and IEC. It also covers fire performance, oil and chemical resistance, and flexibility ratings.
Conclusion: SAB's data cables are tailored to meet modern electronic application demands, providing reliable performance across various environments and conditions.
Specifications: PVC data cables with copper screens are designed for fixed and flexible applications, with a temperature range of -30/+70 °C for fixed laying and -5/+70 °C for flexible application. They are flame retardant and self-extinguishing according to IEC 60332-1-2 and VDE 0482-332-1-2 standards, oil-resistant, and RoHS compliant.
Technical Data: Peak operating voltage is 350 V for cables with a cross-section of less than 0.25 mm² and 500 V for those equal to or greater than 0.25 mm². Testing voltage is 1500 V for core/core and 1200 V for core/screen. Minimum bending radius is 5 times the diameter for fixed laying and 10 times for flexible application. Radiation resistance is 8 x 107 cJ/kg.
Construction: Cables consist of bare copper strands with PVC insulation and a grey PVC sheath. Stranding involves cores twisted to pairs, wrapped in PETP foil, and screened with tinned copper braiding.
Outstanding Features: Good electromagnetic compatibility, flexibility, small outer diameter, and small bending radius. PFAS-free.
Marking and Dimensions: Detailed marking examples and dimensions for various cable configurations, including the number of cores, cross-section, outer diameter, copper weight, and overall cable weight.
Additional Features: Small outer diameter and bending radius.
See more

Catalog excerpts

Data Cables-2

You will find halogen-free data cables in chapter A

 Open the catalog to page 2
Data Cables-3

Data Cables Applications Modern electronics and miniaturized appliances require data cables with smallest cross sections, best screenings and highest flexibility. SAB data cables meet these requirements to a high degree. Different types of screenings, i.e. single or double screens, tinned copper wrappings or braids, protect the cables against outer high-frequency interference. Different types of strandings (in layers or pair-wise) can prevent mutual interference of adjoining circuits. Especially in the computer era data cables have become essential and must be continously adapted to the latest...

 Open the catalog to page 3
Data Cables-4

bare copper strands with reference to VDE 0812 bare copper strands bare copper strands acc. to ASTM B 286 tinned copper strands tinned copper strands acc. to ASTM B 286 silver-plated strands overall copper screen silver-plated screen no coupling of individual signals, low influence of nighboured cable circuits effective suppression of crosstalk and side-to-side crosstalk effects drain wire peak operating voltage max. 48 V peak operating voltage max. 350 V peak operating voltage max. 500 V peak operating voltage 900 V voltage UL/CSA 300 V testing voltage 600 V testing voltage 1500 V testing voltage...

 Open the catalog to page 4
Data Cables-5

marking example: SOB BROCKSKES ■ D-VIERSEN ■ LIYY 32x0,25mm2 C Technical data Peak operating voltage: Testing voltage: fixed laying: flexible application: Radiation resistance: Temperature range fixed laying: flexible application: Fire performance: Chem. resistance: Absence of harmful substances: see chapter N „Technical data” flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 acc. to internal standard, see chapter N „Technical data” see chapter N „Technical data” acc. to RoHS directive of the European Union, see chapter N „Technical data” Construction: Conductor:...

 Open the catalog to page 5
Data Cables-6

marking example: SOB BROCKSKES ■ D-VIERSEN ■ LIYY 32x0,25mm2 C Other dimensions and colours are possible on request.

 Open the catalog to page 6
Data Cables-7

Data CablesLiYY TP PVC data cable, twisted pairs marking example: SAB BROCKSKES • D-VIERSEN • LIYY TP 3x2x0,25mm2 C Conductor: bare copper strands Colour code: with reference to DIN 47100 Stranding: cores twisted to pairs, pairs twisted in layers Wrapping: PETP foil Sheath colour: grey (RAL 7032) » flexible» small outer diameter » small bending radius » PFAS freeTechnical data: Peak operating voltage: < 0,25 mm2 = max. 350 V Testing voltage: core/core 1500 V Min. bending radiusfixed laying: 5 x dflexible application: 10 x d Capacitance: see chapter N „Technical data” Radiation resistance: 8 x...

 Open the catalog to page 7
Data Cables-8

LiYCY PVC data cable with overall copper screen KSKES • D-VIERSEN • LIYCY 5x0,25mm2 C CB""S FREE marking example:SRB BROCKSKES • D-VIERSEN • LIYCY 5x0,25mma C acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Oil resistance: acc. to internal standard, see chapter N „Technical data” Chem. resistance: see chapter N „Technical data” Absence of acc. to RoHS directive of the European Union, harmful substances: see chapter N „Technical data” Construction: Conductor: bare copper strands Colour code: with reference to DIN 47100 Stranding: in layers Wrapping: PETP foil Screen: tinned copper braiding Sheath material:...

 Open the catalog to page 8
Data Cables-9

LiYCY PVC data cable with overall copper screen KSKES • D-VIERSEN • LIYCY 5x0,25mm2 C CB""S FREE marking example:SRB BROCKSKES • D-VIERSEN • LIYCY 5x0,25mma C item no. Other dimensions and colours are possible on request.

 Open the catalog to page 9
Data Cables-10

Data Cables PVC data cable, twisted pairs with overall copper screen D-VIERSEN · LIYCY (B) TP 3x2x0,25mm² C marking example: S BRÖCKSKES · D-VIERSEN · LIYCY (B) TP 3x2x0,25mm² C Conductor: bare copper strands with reference to VDE 0812 Insulation: PVC, TI2 Conductor: bare copper strands acc. to EN 50363-3 + VDE 0207-363-3 with reference to VDE 0812 Colour code: with reference to DIN 47100 Insulation: PVC, TI2 to pairs, pairs twisted in layers Stranding: cores twisted acc. Wrapping: PETP foilto EN 50363-3 + VDE 0207-363-3 Screen: tinned copper braiding Colour code: with reference to DIN 47100...

 Open the catalog to page 10
Data Cables-11

Technical data: Peak operating voltage: Testing voltage: fixed laying: flexible application: Radiation resistance: Temperature range fixed laying: flexible application: Fire performance: Chem. resistance: Absence of harmful substances: see chapter N „Technical data” flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 acc. to internal standard, see chapter N „Technical data” see chapter N „Technical data” acc. to RoHS directive of the European Union, see chapter N „Technical data” Construction: Conductor: bare copper strands, extra fine wires acc. to EN 50363-3 + VDE...

 Open the catalog to page 11
Data Cables-12

Technical data: Conductor: bare copper strands Colour code: with reference to DIN 47100 Stranding: 2 cores twisted to pairs Screen: wrapped pair-wise with tinned copper wires Stranding: pairs in concentric layers Wrapping: PETP foil Screen: tinned copper braiding with a tinned copper drain wire (equal to conductor section) Sheath colour: grey (RAL 7032) Peak operating voltage: < 0,25 mm2 = max. 350 V Testing voltage: core/core 1500 V Capacitance: see chapter N „Technical data” Radiation resistance: 8 x 107 cJ/kg Temperature range Fire performance: flame retardant and self-extinguishing Oil resistance:...

 Open the catalog to page 12
Data Cables-13

Data CablesSRYD 311 semi rigid PVC data cable SflB BROCKSKES ■ D-VIERSEN ■ 03112520 SRY D 311 20 AWG/25c 03112025 U AWM Style 2464 80°C 300V CSA AWM I/II A/B 80°C 300V FT1 FT2 C Other dimensions and colours are possible on request. On request with colour code

 Open the catalog to page 13
Data Cables-14

SRYD 321 C semi rigid PVC data cable with overall copper screen Conductor: bare copper strands acc. to ASTM B 286 Colour code: acc. to colour code US 2, see chapter N „Technical data” Wrapping: PETP foil Screen: tinned copper braiding Sheath colour: grey (RAL 7032) Outstanding features: » good EMC characteristic » flexible » small outer diameter » small bending radius » PFAS free Technical data: Voltage UL/CSA: Testing voltage: fixed laying: flexible application: Temperature range fixed laying: flexible application: Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2...

 Open the catalog to page 14

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Dynamic Cables

    30  Pages

  2. Tray Cables

    19  Pages

  3. Tactical Cables

    12  Pages

  4. Reeling Cables

    16  Pages

  5. Special cables

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.