Compensating | Thermocouple Extension Cables
32Pages

{{requestButtons}}

Catalog excerpts

Compensating | Thermocouple Extension Cables - 1

COMPENSATING AND EXTENSION CABLES

Open the catalog to page 1
Compensating | Thermocouple Extension Cables - 2

Compensating and extension cables Content page Applications Selection tables Compensating and extension cables for thermocouples PVC insulated compensating and extension cables ■ A 1 L twisted Screened PVC insulated compensating and extension cables ■ A5L with overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +70°C . . . . . . with overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +70°C . . . . . . with overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +70°C . . . . . . with...

Open the catalog to page 2
Compensating | Thermocouple Extension Cables - 3

Compensating and extension cables Content page temperature Screened Besilen® insulated compensating and extension cables ■ A6L with alu-foil screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +180°C . . . . with alu-foil screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +180°C . . . . with alu-foil screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +180°C . . . . with overall copper screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +180°C . . . . with overall...

Open the catalog to page 3
Compensating | Thermocouple Extension Cables - 4

Compensating and extension cables Applications n General Information Temperature is an important factor in many areas concerning the environment, scientific research and production. It is a thermodynamic variable that defines the heat content of a material. Material strength changes with alternating temperature. As a consequence, the characteristics of materials have to be examined at different temperatures. To obtain a temperature value, defined temperature parameters are used. Here the parameters can be defined, for example, as the freezing and boiling points of water. For temperature...

Open the catalog to page 4
Compensating | Thermocouple Extension Cables - 5

Compensating and extension cables Applications n Electrical characteristics Material Specific electric resistance at 20°C μ Ω x cm n Because the thermal electromotive force values are decisive, the indicated specific resistance and meter resistance figures can only be considered as approximate values, tolerances have to be agreed between producer and customer. Limit deviations within the thermoelectric voltage range can only be guaranteed for positive and negative conductors bought together from S BRÖCKSKES GmbH & Co. KG. The standard DIN 43710 was withdrawn in April 1994, but we continue,...

Open the catalog to page 5
Compensating | Thermocouple Extension Cables - 6

Compensating and extension cables Hybrid thermocouple cable JX Compensating and extension cables for thermocouples Cable type Selection table Extension cables for thermocouples FE-CuNi and NiCr-Ni Connection cables for resistance thermometers Fibre-glass braiding Stex Screened Steel wire armouring Temperature range of isolation fixed laying* Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Fire performance: no flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25 Cat. C resp. D Fire performance:...

Open the catalog to page 6
Compensating | Thermocouple Extension Cables - 7

Compensating and extension cables Selection table 180 flex 180 C flex 180 highflex 180 C highflex Extension cables for thermocouples FE-CuNi and NiCr-Ni Compensating and extension cables for thermocouples Cable type Connection cables for resistance thermometers Fibre-glass braiding Steel wire armouring Temperature range of isolation fixed laying* Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Standards and approvals Fire performance: no flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25...

Open the catalog to page 7
Compensating | Thermocouple Extension Cables - 8

Compensating and extension cables PVC insulated cables A 1 L twisted · A 1 L single · A 16 L Also available with cross-sections 1,0 mm², 0,75 mm², 0,5 mm² and 0,22 mm²! Construction: Insulation: Stranding: Conductor construction: Technical data: 2 cores together 2 cores seperately A 16 L: 2 cores parallel positive conductor with coloured stripe Radiation resistance: Temperature range of insulation: fixed laying: -40/+70 °C flexible application: +5/+70 °C Insulation resistance: Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Absence of...

Open the catalog to page 8
Compensating | Thermocouple Extension Cables - 9

Compensating and extension cables PVC insulated cables A 9 L · A 9-100 L · A 9-075 L · A 9-050 L · A 9-022 L Construction: Insulation: Technical data: Radiation resistance: Sheath material: Temperature range of insulation: fixed laying: -40/+70 °C flexible application: +5/+70 °C Insulation resistance: Conductor construction: Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Absence of harmful substances: acc. to RoHS directive of the European Union see chapter N „Technical Data“ Type: Conductor cross section: Outer diameter: Weight/100m: cable...

Open the catalog to page 9
Compensating | Thermocouple Extension Cables - 10

Compensating and extension cables PVC insulated cables A 12 L · A 12 D A 12 L: Also available with cross-sections 1,0 mm², 0,75 mm², 0,5 mm² and 0,22 mm²! Construction: Insulation: Technical data: Radiation resistance: Sheath material: Temperature range of insulation: fixed laying: -40/+70 °C flexible application: +5/+70 °C Insulation resistance: strand resp. wire Type: Conductor cross section: Outer diameter: Weight/100m: Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Absence of harmful substances: Conductor construction: acc. to RoHS...

Open the catalog to page 10
Compensating | Thermocouple Extension Cables - 11

Construction: Insulation: Compensating and extension cables Technical data: Radiation resistance: PETP foil Temperature range of insulation: fixed laying: -40/+70 °C flexible application: +5/+70 °C tinned copper braiding Insulation resistance: Sheath material: Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 Conductor construction: Absence of harmful substances: acc. to RoHS directive of the European Union see chapter N „Technical Data“ Type: Conductor cross section: Outer diameter: Weight/100m: cable type Type T Type J Type K Type K Type K...

Open the catalog to page 11

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Reeling Cables

    16 Pages

  2. TC 301

    1 Pages

  3. MTC 205

    1 Pages

  4. MTC 204

    1 Pages

  5. MTC 203

    1 Pages

  6. MTC 201

    1 Pages

  7. Tray Cables

    21 Pages

  8. Data Cables

    22 Pages

  9. SABmed Line

    1 Pages

  10. CA 156 FRNC

    1 Pages

  11. Cord Grips

    26 Pages