Cleanroom Cables

Cleanroom Cables
1 / 12 PagesView full catalog

Cleanroom Cables

Product catalog summary
Applications
SAB Bröckskes provides cables tailored for cleanroom environments, adhering to VDI 2083 sheet 8 guidelines. These are ideal for semiconductor production, display manufacturing, and medical engineering, complying with DIN EN ISO 14644-1 standards for air cleanliness.
Company Overview
SAB Bröckskes GmbH & Co. KG, established in 1947, is a family-owned business specializing in custom cable solutions. With around 550 employees, the company focuses on quality and innovation, holding certifications like DIN EN ISO 9001 and ISO 14001, and is committed to sustainability with a global presence.
Industrial Ethernet Cables
The CATLine series includes CAT 5e, CAT 6A, and CAT 7A cables, suitable for cable tracks with UL recognition. These cables have a TPE sheath, are flame retardant, oil-resistant, and comply with RoHS directives, meeting various electrical and transmission standards.
Cable Track Cables
Products such as the SD 776 and S 776 are designed for continuous flexibility in data and control applications. They offer high flexibility, oil resistance, and are classified under air cleanliness class 1. The SD 780 C and S 780 C variants feature an overall copper screen for enhanced EMC characteristics.
Torsion Cables
The RT 123 D TP and RT 793 D are torsional cables with UL recognition and CSA approval, designed for applications requiring high flexibility and durability.
Technical Specifications
All cables are designed to operate within specific voltage and temperature ranges, with detailed construction specifications including conductor materials, insulation types, and sheath colors. They are tested for flame retardancy and are free from harmful substances as per European Union RoHS directives.
Specifications
  • Sheath Material: TPE, available in black (RAL 9005) and whitegreen (RAL 6019).
  • Outstanding Features: Flexible at low temperatures, high abrasion resistance, small outer diameter, oil resistant, good EMC characteristics, PFAS free.
  • Voltage Ratings: Peak operating voltage up to 350 V, UL/CSA voltage 300 V, testing voltage core/core and core/screen 2000 V.
  • Torsion Angle: Up to ± 450°/1 m for RT 123 D TP (B) and up to ± 360°/1 m for RT 793 D.
  • Temperature Range: Fixed laying up to +80 °C, flexible application -50/+70 °C (DIN VDE UL/CSA), -40/+70 °C.
  • Cleanroom Classification: Air cleanliness class 1 according to DIN EN ISO 14644-1.
  • Absence of Harmful Substances: Compliant with RoHS directive of the European Union.
Construction
  • Conductor: Bare copper strands, extra fine wire, with reference to VDE 0812 and IEC 60228, VDE 0295, class 6.
  • Insulation: TPE.
  • Colour Code: US 2 for RT 123 D TP (B), black cores with consecutive numbers for RT 793 D.
  • Stranding: Cores twisted to pairs in specially adjusted layering.
  • Screen: Wrapped with bare copper wires.
  • Wrapping: Non-woven tape.
Technical Data
  • Nominal Voltage: Uo/U 300/500 V for RT 793 D.
  • Voltage UL/CSA: 600 V for RT 793 D.
  • Testing Voltage: Core/core 3000 V, core/screen 2000 V for RT 793 D.
  • Min. Bending Radius: Continuously flexible: 7.5 x d.
Additional Information
Other dimensions and colours are available on request. The cables are marked with examples such as RT 123 D TP (B) and RT 793 D, indicating torsional data and control cables with overall copper screen.
See more

Catalog excerpts

Cleanroom Cables-1

Cables for cleanroom technology

 Open the catalog to page 1
Cleanroom Cables-2

SRB jean Industrial Ethernet Cables SRB ■ an CATLine CAT 5e S SRB ■ -an CATLine CAT 6A S SRB ■ an CATLine CAT 7A S SRB jean Cable Track Cables SRB an SD 776 SRB an S 776 SRB ■ -anSD780C SRB ■ ;an S 780 C SRB ■ -anSD787CTP SRB jean Torsion Cables CAT 5e Industrial Ethernet cable, suitable for cable tracks with UL recognition CAT 6A Gigabit Ethernet cable, suitable for cable tracks with UL recognition CAT 7A Gigabit Ethernet cable, suitable for cable tracks with UL recognition continuously flexible data cable continuously flexible control cable continuously flexible data cable with overall copper...

 Open the catalog to page 2
Cleanroom Cables-3

Cables for cleanroom technologyApplicationsApplication Cleanroom Cables Application examples: » SRB an cables are used in cleanrooms. » Examples are the production of semiconductors, machines for display manufacturing, devices for biological or medical engineering, food and medical production. » SRB an cables meet highest requirements acc. to The guideline VDI 2083 sheet 8 treats the suitability of equipment for cleanrooms with respect to planning, production, maintenance, recovering and proof. The examination of our SOB-sh cables by the Fraunhofer Institut showed that our SOB ,-iea cables met...

 Open the catalog to page 3
Cleanroom Cables-4

SAB Bröckskes GmbH & Co. KG Customised connection solutions quality & innovation since 1947 For three generations, B Bröckskes has stood for customised connection solutions in cable and measurement technology. Having grown from a one-man operation, we now employ approx. 550 people and realise more than 1,500 customer-specific special constructions every year. Our strength lies in the development and production of customised solutions that are perfectly tailored to our customers‘ requirements. partnership. Our products are in use in more than 100 countries and fulfil the highest quality standards,...

 Open the catalog to page 4
Cleanroom Cables-5

SAB Bröckskes GmbH & Co. KG Family business in its third generation 1947 - 1989 Peter Bröckskes sen. Visionary with a thirst for action: Peter Bröckskes Senior was a successful company founder with determination, hard work and a pioneering spirit. He started out in 1947 as a one-man alarm system company and continuously developed new products. In the course of his entrepreneurial career, he overcame setbacks and repeatedly managed to recognise gaps in the market and develop new products. 1989 - 2017 Peter Bröckskes After studying business administration, Peter Bröckskes joined the company in...

 Open the catalog to page 5
Cleanroom Cables-6

Industrial Ethernet cables CATLine CAT 5e S CATLine CAT 6A S CATLine CAT 7A S marking example: S BRÖCKSKES · D-VIERSEN · S Clean Cat.7A S 4x2x26AWG 1777-9003 U AWM Style 20549 80°C 300V C RoHS and current meter marking Dimension: Conductor: Insulation: Colour code: Stranding: Wrapping: Sheath material: Sheath colour: Technical data: Dimension: Peak operating voltage: Voltage UL: Testing voltage core/core: core/screen: Min. bending radius fixed laying: flexible application: continuously flexible: Temperature range fixed laying: flexible application: Fire performance: Characteristic impedance:...

 Open the catalog to page 6
Cleanroom Cables-7

Cable Track Cables SD 776 S 776 continuously flexible data cable continuously flexible control cable BRÖCKSKES · D-VIERSEN · S Clean SD 776 · 14 x 0,25 mm² C marking example: S BRÖCKSKES · D-VIERSEN · S Clean SD 776 · 14 x 0,25 mm² C RoHS and current meter marking BRÖCKSKES · D-VIERSEN · S Clean S 776 · 4 G 1,0 mm² C marking example: S BRÖCKSKES · D-VIERSEN · S Clean S 776 · 4 G 1,0 mm² C RoHS and current meter marking Technical data: Peak operating voltage: Nominal voltage: Testing voltage: Temperature range fixed laying: flexible application: Absence of harmful substances: acc. to RoHS directive...

 Open the catalog to page 7
Cleanroom Cables-8

SAB. ■ SD 780 C continuously flexible data cable with overall copper screen SAB S 780 C continuously flexible control cable with overall copper screen • D-VIERSEN • SRB Clean SD 780 • 18 x 0,34 mm2 C marking example: SRB BROCKSKES • D-VIERSEN • SRB Clean SD 780 • 18 x 0,34 mm2 c RoHS and current meter marking S • D-VIERSEN • SRB Clean S 780 C • 4 G 1,0 mm2 c ' marking example: SRB BROCKSKES • D-VIERSEN • SRB Clean S 780 C • 4 G 1,0 mm2 c RoHS and current meter marking Technical data: Conductor: SD 780 C: Peak operating voltage: SD 780 C: bare copper strands, extra fine wire max. 350 V bare copper...

 Open the catalog to page 8
Cleanroom Cables-9

Cable Track Cables SD 787 C TP continuously flexible paired data cable with overall copper screen · D-VIERSEN · S Clean SD 787 C TP · 7 x 2 x 0,25 mm² C marking example: S BRÖCKSKES · D-VIERSEN · S Clean SD 787 C TP · 7 x 2 x 0,25 mm² C RoHS and current meter marking Technical data: Peak operating voltage: Testing voltage: tinned copper strands, extra fine wire with reference to VDE 0812 Colour code: cores twisted to pairs in specially adjusted layering non-woven tape Temperature range fixed laying: flexible application: tinned copper braiding non-woven tape Sheath material: Sheath colour: Absence...

 Open the catalog to page 9
Cleanroom Cables-10

Construction: Conductor: bare copper strands, extra fine wire, Colour code: colour code US 2 Stranding: cores twisted to pairs in specially adjusted layering Wrapping: netting tape, non-woven tape Screen: wrapped with bare copper wires Drain wire: bare copper strands, extra fine wire 0,34 mm2 Wrapping: non-woven tape Sheath colour: whitegreen (RAL 6019) Peak operating voltage: max. 350 V Testing voltage: core/core 2000 V Temperature range DIN VDE UL/CSA: up to +80 °C harmful substances: acc. to RoHS directive of the European Union » rugged and reliable » torsion angle up to ± 450° over 1 m »...

 Open the catalog to page 10
Cleanroom Cables-11

torsional control cable with overall copper screen @CMS FREE marking example: SflB BROCKSKES ■ D-VIERSEN ■ SflB Clean RT 793 D 16 AWG/4c 37930415 U AWM Style 21060 80°C 600V CSA AWM I/II A/B 80°C 600V FT1 FT2 C Conductor: bare copper strands Colour code: black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334, green-yellow earth wire from 3 cores Stranding: specially adjusted layering Wrapping: netting tape, non-woven tape Screen: wrapped with bare copper wires Wrapping: non-woven tape Sheath colour: whitegreen (RAL 6019) Technical data: Nominal voltage: Uo/U 300/500 V Testing voltage:...

 Open the catalog to page 11

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Dynamic Cables

    30  Pages

  2. Data Cables

    22  Pages

  3. Tray Cables

    19  Pages

  4. Tactical Cables

    12  Pages

  5. Reeling Cables

    16  Pages

  6. Special cables

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.