BL-LINE - CABLES FOR SHIPBUILDING
Open the catalog to page 1Cables for Shipbuilding Content Who we are Selection table halogen-free CAT 5e Industrial Ethernet cable . . . . . . . . . . . . . . . . . . . halogen-free CAT 6A Gigabit Ethernet cable . . . . . . . . . . . . . . . . . . . . halogen-free CAT 7A Gigabit Ethernet cable . . . . . . . . . . . . . . . . . . . . Cables for maritime use CATLine BL-Line Ethernet ■ CATLine CAT 5e BL ■ CATLine CAT 6A BL ■ CATLine CAT 7A BL S BL-Line Data ■ A BL 405 FRNC ■ A BL 415 C FRNC ■ A BL 443 C FRNC TT ■ A BL 445 C FRNC TP ■ A BL 446 C FRNC FTP S BL-Line Control ■ A BL 400 FRNC ■ A BL 438 C FRNC S BL-Line...
Open the catalog to page 2S BRÖCKSKES Family business in the third generation years of experience in cable and wire manufacturing as well as in temperature measurement technology turned a one-man business into a company with more than 550 employees. We prove our strength every year with more than 1500 special products according to customers' requirements. Each product is a new challenge for our creative technical team. We at B see ourselves as a manufacturer and a service provider – in the sense of true partnership and the greatest possible customer orientation. Today, the quality of our products is known and...
Open the catalog to page 3Type approvals Voltage range Temperature range fixed laying* from to CATLine CAT 5e BL ‘CATLine CAT 6A BL CATLine CAT 7A BL Ethernet cable Data cable Control cable Power cable screened twisted pairs twisted triple +180°C + 90°C + 70°C – 40°C – 55°C Peak operating voltage max. 90 V Peak operating voltage max. 300 V Peak operating voltage max. 350 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 0,6/1 kV Voltage UL 300 V Voltage UL/cUL 600 V Halogen-free acc. to IEC 60754-1 + VDE 0482-754-1 Fire performance: no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A Fire...
Open the catalog to page 4Cables for Shipbuilding CATLine CAT 5e BL CATLine CAT 6A BL CATLine CAT 7A BL halogen-free Ethernet cables for maritime use 4x2x26/7AWG 1747-4621 u AWM Style 21080 75°C 300V C Marking for CATLine CAT 7A BL 17474421: S BRÖCKSKES · D-VIERSEN · Cat.7A BL 4x2x26/7AWG 1747-4621 u AWM Style 21080 75°C 300V C Construction: Dimension: 4 x 2 x 24 AWG, 4 x 2 x 26 AWG bare copper strands, fine wires special polymer Colour code: blue, yellow, white, orange white-blue/blue, white-orange/orange, white-green/green, white-brown/brown star quad cores twisted to pairs, pairs together cores twisted to pairs,...
Open the catalog to page 5Cables for Shipbuilding S BL 405 FRNC L BL-Line Data - halogen-free flexible data cable Marking for S BL 405 FRNC 64051650: S BRÖCKSKES · D-VIERSEN · S BL 405 FRNC 16 x 0,5mm² - IEC 60332-3-22 - 350V C and current meter marking Construction: Conductor: Technical Data: Peak operating voltage: Min. bending radius fixed laying: flexible application: Colour code: Sheath colour: flame retardant and self-extinguishing very good acc. to RoHS directive of the European Union Absence of harmful substances: in compliance with IEC 60754-2 + VDE 0482-754-2 no development of corrosive conflagration gases...
Open the catalog to page 6Cables for Shipbuilding S BL 415 C FRNC L BL-Line Data - halogen-free flexible data cable with overall copper screen Marking for S BL 415 C FRNC 64150550: S BRÖCKSKES · D-VIERSEN · S BL 415 C FRNC 5 x 0,5mm² - IEC 60332-3-22 - 350V C and current meter marking Technical Data: tinned copper strands with reference to VDE 0812 resp. IEC 60228, VDE 0295, class 5 Peak operating voltage: Testing voltage: Colour code: Min. bending radius fixed laying: flexible application: tinned copper braiding Temperature range fixed laying: flexible application: Sheath material: Fire performance: no flame...
Open the catalog to page 7Cables for Shipbuilding S BL 443 C FRNC TT L BL-Line Data - halogen-free flexible data cable, twisted triple with overall copper screen Marking for S BL 443 C FRNC TT 64430734: S BRÖCKSKES · D-VIERSEN · S BL 443 C FRNC TT 7 x 3 x 0,34 mm² - IEC 60332-3-22 - 300V Construction: Conductor: C and current meter marking Technical Data: Peak operating voltage: Testing voltage: tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Colour code: ≤ 0,25 mm² = DIN 47100 ≥ 0,34 mm² = white, blue, red with printed triple number Min. bending radius fixed laying: flexible application: cores white,...
Open the catalog to page 8Cables for Shipbuilding S BL 445 C FRNC TP L BL-Line Data - halogen-free flexible paired data cable with overall copper screen Marking for S BL 445 C FRNC TP 64450325: S BRÖCKSKES · D-VIERSEN · S BL 445 C FRNC TP 3 x 2 x 0,25 mm² - IEC 60332-3-22 - 350V C and current meter marking Technical Data: Construction: tinned copper strands with reference to VDE 0812 resp. IEC 60228, VDE 0295, class 5 Peak operating voltage: Testing voltage: Colour code: pairwise, pairs in layers Min. bending radius fixed laying: flexible application: tinned copper braiding Temperature range fixed laying: flexible...
Open the catalog to page 9Cables for Shipbuilding S BL 446 C FRNC FTP L BL-Line Data - halogen-free flexible paired data cable with aluminum pair screen and overall copper screen Marking for S BL 446 C FRNC FTP 64462475: S BRÖCKSKES · D-VIERSEN · S BL 446 C FRNC FTP 24 x (2 x 0,75 mm²)ST - IEC 60332-3-22 - 300V Construction: Conductor: ≤ 0,25 mm² = DIN 47100 ≥ 0,34 mm² = white, blue with marking, pairnumber Testing voltage: Colour code: Technical Data: Peak operating voltage: tinned copper strands acc. to IEC 60228, VDE 0295, class 5 C and current meter marking Min. bending radius fixed laying: flexible application:...
Open the catalog to page 10Cables for Shipbuilding S BL 400 FRNC L BL-Line Control - halogen-free flexible control cable 300/500 V Marking for S BL 400 FRNC 64001215: S BRÖCKSKES · D-VIERSEN · S BL 400 FRNC 12 x 1,5 mm² - IEC 60332-3-22 - 300/500V Construction: Conductor: C and current meter marking Technical Data: tinned copper strands acc. to IEC 60228, VDE 0295, class 5 Nominal voltage: Testing voltage: Colour code: black conductors with consecutive numbers acc. to EN 50334 + VDE 0293-334, green-yellow earth wire from 3 conductors Min. bending radius fixed laying: flexible application: Temperature range fixed...
Open the catalog to page 11All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures
-
Drag Chain Cables
51 Pages
-
Halogen-free Cables
64 Pages
-
Harnessed Ethernet Cables
12 Pages
-
Special Cable Manufacturer
20 Pages
-
Cleanroom Cables
12 Pages
-
CONTACT TEMPERATURE MEASUREMENT
16 Pages
-
Cables for wind power plant
28 Pages
-
Reeling Cables
16 Pages
-
Handling Cables
40 Pages
-
Flexible Cables C1
20 Pages
-
High-Temperature Cables & Wires
44 Pages
-
TC 301
1 Pages
-
MTC 205
1 Pages
-
MTC 204
1 Pages
-
MTC 203
1 Pages
-
MTC 201
1 Pages
-
Lift Control Cables
12 Pages
-
Torsion cables
8 Pages
-
Harnessed Cables - Asseblies
36 Pages
-
Cables for Sensors
8 Pages
-
Cables for Airport Equipment
20 Pages
-
USB 2.0/3.0 Cables
12 Pages
-
Cable Asseblies
36 Pages
-
Cables for Railway Technology
32 Pages
-
Servo Motor Cables
23 Pages
-
Tray Cables
21 Pages
-
Data Cables
22 Pages
-
Hybrid and Special Cables
31 Pages
-
SABmed Line
1 Pages
-
Profinet cable
1 Pages
-
Temperature Measurement
12 Pages
-
Heat Resistant Cable
1 Pages
-
SABIX A 147 FRNC
1 Pages
-
CA 156 FRNC
1 Pages
-
Cord Grips
26 Pages