Cables for Railway Technology
32Pages

{{requestButtons}}

Catalog excerpts

Cables for Railway Technology - 2

Cables for Railway Technology Content Who we are Overview of fire protection requirements for cables Selection index for cables for railway technology Cables for Railway technology ■ A A 146 FRNC wiring cable 300/500 V, tested acc. to EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wiring cable 450/750 V, tested acc. to EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Rail Control with numbered cores, tested acc. to EN 45545-2 . . . . . . . . . . . . . . S Rail Control with numbered cores and overall copper screen, tested acc. to EN 45545-2 . ....

Open the catalog to page 2
Cables for Railway Technology - 3

Cables for Railway Technology Who we are years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff members. Our strength is not only the production of standard products but also the development and manufacturing of special products acc. to customers’ specifications. Every year we manufacture more than 1500 special products on our customers’ request. Every single product is a challenge for our technical team. We at B BRÖCKSKES see ourselves as manufacturer and service provider - in the...

Open the catalog to page 3
Cables for Railway Technology - 4

Extract from EN 45545-2 table 5 requirement set R15 (EL1A) for the respective hazard classes SPECIAL CABLES

Open the catalog to page 4
Cables for Railway Technology - 5

Cable type *The temperature range for flexible application is mentioned on the particular catalogue page SPECIAL CABLES

Open the catalog to page 5
Cables for Railway Technology - 6

Cables for Railway TechnologySBBIX® A 14 6 FR N C SfiBIX® A 15 6 FRN C 450/750 V warn BROCKSKES ■ D-VIERSEN ■ SflBIX* A 146 FRNC 300/500V 0,5 mm2 C C EH[ B«"S Marking for SfiBIX" A 146 FRNC 61460150: SRB BROCKSKES ■ D-VIERSEN ■ SfiBIX" A 146 FRNC 300/500 V 0,5 mm2 C Outstanding features: halogen-free no flame propagation flame retardant and self-extinguishing very good stripping flexible fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3 SfiBIX'-'A 146 FRNC item no. nominal largest outer-0 copper cable cross-section single wire ± 5% figure weight...

Open the catalog to page 6
Cables for Railway Technology - 7

Cables for Railway TechnologySRBIX® R 600 FRNC SRBIX® Rail Control with numbered cores ■S • D-VIERSEN • 5RS R 600 FRNC 12 x 1,5 mm2 C C ER[ RnHS Marking for SRBIX" R 600 FRNC 66001215: SRB BRQCKSKES • D-VIERSEN • SRBIX" R 600 FRNC 12 x 1,5 mm2 C Tested at reference types. item no. no. of cores largest outer-0 copper cable x cross section single wire ± 5% figure weight item no. no. of cores largest outer-0 copper cable x cross section single wire ± 5% figure weight Other dimensions and colours are possible on request. SPECIAL CABLES

Open the catalog to page 7
Cables for Railway Technology - 8

Cables for Railway TechnologySRBIX® R 638 FRNCSRBIX® Rail Control with numbered cores and overall copper screen SKES • D-VIERSEN • SflBIX® R 638 FRNC 5 x 1,5 mm2 C Marking for SRBIX" R 638 FRNC 66380515: SRB BROCKSKES • D-VIERSEN • SRBIX" R 638 FRNC 5 x 1,5 mm2 C item no. no. of cores largest outer-0 copper cable x cross section single wire ± 5% figure weight item no. no. of cores largest outer-0 copper cable x cross section single wire ± 5% figure weight Other dimensions and colours are possible on request. Tested at reference types. SPECIAL CABLES

Open the catalog to page 8
Cables for Railway Technology - 9

Cables for Railway TechnologySfiBIX"' R 605 FRNC SfiBIX® Rail Data D-VIERSEN • SfiBIX® R 605 FRNC 32 x 0,5 mm2 C ER[ BnHS Marking for SfiBIX” R 605 FRNC 66053250: SRB BROCKSKES • D-VIERSEN • SfiBIX” R 605 FRNC 32 x 0,5 mm2 C Tested at reference types. Outstanding features: • halogen-free no flame propagation flame retardant and self-extinguishing • fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3 flame retardant acc. to UN/ECE R118 item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight item no. no. of cores outer-0 copper...

Open the catalog to page 9
Cables for Railway Technology - 10

Cables for Railway TechnologySfiBIX"' R 605 FRNC SfiBIX® Rail Data D-VIERSEN • SfiBIX® R 605 FRNC 32 x 0,5 mm2 C ER[ BnHS Marking for SfiBIX” R 605 FRNC 66053250: SRB BROCKSKES • D-VIERSEN • SfiBIX” R 605 FRNC 32 x 0,5 mm2 C item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight Other dimensions and colours are possible on request. SPECIAL CABLES

Open the catalog to page 10
Cables for Railway Technology - 11

RoH^ Marking for SRBIX" R 615 FRNC 66150550: SRB BROCKSKES • D-VIERSEN • SRBIX" R 615 FRNC 5 x 0,5 mm2C Tested at reference types. Outstanding features: • halogen-free • good EMC characteristics no flame propagation flame retardant and self-extinguishing • fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3 tested acc. to American ASTM standard flame retardant acc. to UN/ECE R118 item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight Continued on next...

Open the catalog to page 11
Cables for Railway Technology - 12

RoH^ Marking for SflBIX® R 615 FRNC 66150550: SAB BROCKSKES • D-VIERSEN • SflBIX® R 615 FRNC 5 x 0,5 mm2 C item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight Other dimensions and colours are possible on request. SPECIAL CABLES srbvw;

Open the catalog to page 12
Cables for Railway Technology - 13

SRBIX® Rail Data paired with overall copper screen 645 FRNC TP 3 x 2 x 0,25 mm2 CMarking for SRBIX" R 645 FRNC TP 66450325: SRB BROCKSKES ■ D-VIERSEN ■ SRBIX" R 645 FRNC TP 3 x 2 x 0,25 mm2C Tested at reference types. Outstanding features: • halogen-free no flame propagation • good EMC characteristics • flame retardant and self-extinguishing • fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3 tested acc. to American ASTM standard flame retardant acc. to UN/ECE R118 • good transmission rates and crosstalk attenuation item no no. of pairs outer-0...

Open the catalog to page 13

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Reeling Cables

    16 Pages

  2. TC 301

    1 Pages

  3. MTC 204

    1 Pages

  4. MTC 203

    1 Pages

  5. MTC 201

    1 Pages

  6. Tray Cables

    21 Pages

  7. Data Cables

    22 Pages

  8. SABmed Line

    1 Pages

  9. CA 156 FRNC

    1 Pages

  10. Cord Grips

    26 Pages