FOR THE LAMP AND LIGHT INDUSTRY
Open the catalog to page 1Lamp and light industry Content Who we are FEP/PVC lamp cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fireproof installation cable ■ S Pyro 735 halogen-free fireproof installation cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Besilen® single conductors acc. to DIN VDE 0250 part 502 ■ N2GFA/2GFA Besilen® insulated wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 2years of experience in cable and wire manufacturing as well as in temperature measurement technology turned a one-man business into a company with more than 550 employees. We prove our strength every year with more than 1500 special products according to customers' requirements. Each product is a new challenge for our creative technical team. We at SRB see ourselves as a manufacturer and a service provider - in the sense of true partnership and the greatest possible customer orientation. Today, the quality of our products is known and appreciated in more than 100 countries around the world. In...
Open the catalog to page 3TA 835 Y (TR) Our lamp cable is used in the lamp and light industry for the connection of halogen lamps and lighting or rather downlights. This cable is because of design reasons equipped with a transparent PVC outer sheath. The cores have a FEP insulation which is very temperature resistant and which is made to withstand the extremely high temperature of the halogen lights of up to +180 °C Our Besilen® (Silicone) cables are suitable for diverse applications. The product programme ranges from ignition cables to sheathed cables with mechanical protection and cables with flame protection. Therefore,...
Open the catalog to page 4FEP/PVC lamp cable C Einmis Application: For the connection of lamps and lighting. harmful substances: acc. to RoHS directive of the European Union without steel rope item no. no. of cores outer-0 copper cable x cross section ± 5% figure weight Other dimensions and colours are possible on request. with steel rope item no. no. of cores outer-0 copper cable x cross section approx. figure weight Other dimensions and colours are possible on request.
Open the catalog to page 5halogen-free fireproof installation cable • D-VIERSEN • Special Cable 8 x 0,75 mm2 0735-9006 CR £ Marking for SPB Pyro 735 07359006: SOB BR0CKSKES • D-VIERSEN • Special Cable 8 x 0,75 mm2 0735-9006 C Application: For the fireproof istallation of lamps and lighting in the interior of buildings. very good flexibility of corrosive conflagration gases no. of cores x cross section n x mm2 cable weight * kg/km Other dimensions and colours are possible on request. SPECIAL CABLES
Open the catalog to page 6Besilen® insulated wire acc. to DIN VDE 0250 item no. nominal nominal outer-0 copper cable cross section wire-0 ± 5% figure weight * Colour code for single conductors: Other dimensions and colours are possible on request. according to DIN VDE 0250 part 502. Other cross sections with reference to DIN VDE 0250 part 502. SPECIAL CABLES
Open the catalog to page 7Besilen® insulated strands acc. to DIN VDE 0250 Outstanding features:flexible halogen-free 0,75 mm2 VDE standardized flexible at low temperatures heat resistant item no. nominal largest outer-0 copper cable cross section single wire ± 5% figure weight Other dimensions and colours are possible on request. * Colour code for single conductors: ...0 = green-yellow ...1 = blue according to DIN VDE 0250 part 502. Other cross sections with reference to DIN VDE 0250 part 502. SPECIAL www.sab-cable.com
Open the catalog to page 8Besilen® insulated wire with fibre-glass braiding with reference to DIN EN 50525-2-41 Outstanding features: • halogen-free • heat resistant Technical data: Nominal voltage: Uo/U 300/500 V harmful substances: acc. to RoHS directive of the European Union item no. nominal nominal outer-0 copper cable cross section wire-0 ± 5% figure weight Other dimensions and colours are possible on request.
Open the catalog to page 9Besilen® insulated strands with fibre-glass braiding with reference to DIN EN 50525-2-41 Technical data: Nominal voltage: Uo/U 300/500 V Outstanding features: • flexible • heat resistant Testing voltage: harmful substances: acc. to RoHS directive of the European Union item no. nominal largest outer-0 copper cable cross section single wire ± 5% figure weight Other dimensions and colours are possible on request.
Open the catalog to page 10low-voltage connection cable for halogen lamps C/DdCO BROCKSKES • D-VIERSEN • BIAF/YW 2x1,5mm2 EH[ «n"S SAB BROCKSKES • D-VIERSEN • BIAF/YW 2x1,5mm2 • heat resistant PVC outer sheath for ambient temperatures up to 105°C for short-time use • due to flat construction space-saving • simplified connecting possibilities • no wiring with single conductors item no. no. of cores largest dimen- copper cable x cross section single wire sions figure weight Other dimensions and colours are possible on request. SPECIAL CABLES
Open the catalog to page 11Besilen® insulating sleeve, non-fibrous Outstanding features: • halogen-free • heat resistant inside diameter outer 0 weight SPECIAL CABLES iSfiB www.sab-cable.co^
Open the catalog to page 12Besilen® twin cable Technical data: Outstanding features: • halogen-free • heat resistant item no. no. of cores largest dimensions copper cable x cross section single wire figure weight Other dimensions and colours are possible on request. harmful substances: acc. to RoHS directive of the European Union
Open the catalog to page 13Lamp and light industryZKBi Besilen® ignition cable Construction: Technical data: Conductor: tinned copper strands harmful substances: acc. to RoHS directive of the European Union Outstanding features: • halogen-free • heat resistant item no. nominal largest outer-0 copper cable cross section single wire ± 5% figure weight Other dimensions and colours are possible on request.
Open the catalog to page 14Lamp and light industryHZLBi Besilen® high-voltage ignition cable Construction: Technical data: Testing voltage: 5 mm 0: 15 kV harmful substances: acc. to RoHS directive of the European Union Conductor: tinned copper strands 19 x 0,25 mm 0 Sheath colour: reddish brown (similar RAL 3016) Outstanding features: • halogen-free • heat resistant item no. nominal largest outer-0 copper cable cross section single wire ± 5% figure weight Other dimensions and colours are possible on request.