1. Catalogs
  2. S&C Electric Company
  3. S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System

S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System

S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System
1 / 10 PagesView full catalog

S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System

Product catalog summary
Introduction
  • Qualified Persons: Only trained individuals with expertise in electric power distribution should handle the S&C 5800 Series Automatic Switch Control.
  • Instruction Sheet: It is essential to read and keep this document for future reference, with the latest version available online.
  • Warranty: The standard warranty applies according to S&C's conditions of sale.
Safety Information
  • Safety-Alert Messages: Understand the different alert levels: Danger, Warning, Caution, and Notice, indicating the severity of potential hazards.
  • Safety Instructions: Follow all safety instructions and contact S&C for assistance if needed.
  • Replacement Instructions and Labels: Ensure all safety labels are intact and replace them if necessary.
Description
  • IntelliTEAM II System: Enables automatic fault isolation and service restoration using peer-to-peer communications and distributed intelligence.
  • Features: Includes distributed intelligence, automatic load transfer, and safety features to prevent operational issues.
  • S&C 5800 Series Switch Control Overview: The control package includes components like a switch control enclosure, interface connectors, and a faceplate LCD for easy data viewing.
S&C 5800 Series Switch Control Features
  • Quality and Reliability: Manufactured in an ISO 9002-certified plant, designed for tough conditions.
  • Data Logging and Communications: Features flexible communication ports and data logging capabilities.
  • Power Supply and Battery Management: Includes a computer-controlled power supply and battery backup for reliability.
  • Fault Detection and Protection: Offers reliable overcurrent fault detection and phase loss protection.
Additional Features
  • S&C 5801 Features: Customized for overhead switches with specific features for enhanced functionality.
Custom AC Voltage and Current-Signal Conditioning
This section highlights the design and testing of custom AC voltage and current-signal conditioning specifically for the sensors in use, ensuring compatibility and optimal performance.
Specialized Enclosure Wiring
The document describes the specialized wiring within the enclosure, matched to the control cable and switch interface connector, ensuring seamless integration and operation.
Switch Control Installation
The switch control is modular and prewired, requiring only the connection of 120 Vac control power, eliminating the need for discrete field wiring, facilitating easy installation and setup.
Visual Disconnect Feature
The S&C D2 visual disconnect option provides a clear indication of disconnect status in both IntelliLINK software and SCADA status points, ensuring safety by preventing switch operation when open.
Local Selection Reporting
The system supports reporting of local selections made in the pad-mount motor operator cabinet, enhancing monitoring capabilities.
Additional Features for S&C 5802/5803 Switch Control
The switch control is tailored for multi-switch installations, accommodating up to 6 current and 6 voltage sensors, or 9 current and 3 voltage sensors. It includes specialized internal wiring for compatibility with pad-mounted switch operators and sensor cables, ready for integration with only mounting and necessary wiring connections required. Separate automatic control setpoints for each switch allow for independent configuration and operation.
See more

Catalog excerpts

S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-1

S&C 5800 Series Automatic Switch Controls With IntelliTEAM II™ Automatic Restoration System Product Description TABLE OF CONTENTS Section INTRODUCTION Qualified Persons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Read this Instruction Sheet . . . . . . . . . . . . . . . . . . . . . . . 2 Retain this Instruction Sheet. . . . . . . . . . . . . . . . . . . . . . 2 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Latest Document Release . . . . . . . . . . . . . . . . . . . . . . . . 2 SAFETY INFORMATION Understanding Safety-Alert Messages . . . . . . . . . . . . . . 3 Following Safety Instructions . . . . . . . . . . . . . . . . . . . . . 3 Replacement Instructions and Labels . . . . . . . . . . . . . . 3 Location of Safety Labels . . . . . . . . . . . . . . . . . . . . . . . . 4 DESCRIPTION IntelliTEAM II System . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 S&C 5800 Series Switch Control Overview . . . . . . . . . . 5 S&C 5800 Series Switch Control Features . . . . . . . . . . 8 Additional S&C 5801 Features . . . . . . . . . . . . . . . . . . . . 9 Additional S&C 5802/5803 Features . . . . . . . . . . . . . . . . 9 S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection

 Open the catalog to page 1
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-2

INTRODUCTION Qualified Persons !WARNING The equipment covered by this publication must be installed, operated, and maintained by qualified persons who are knowledgeable in the installation, operation, and maintenance of overhead electric power distribution equipment along with the associated hazards. A qualified person is one who is trained and competent in: • The skills and techniques necessary to distinguish exposed live parts from non-live parts of electrical equipment. • The skills and techniques necessary to determine the proper approach distances corresponding to the voltages to which the...

 Open the catalog to page 2
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-3

SAFETY INFORMATION Understanding Safety-Alert Messages There are several types of safety-alert messages which may appear throughout this instruction sheet as well as on labels attached to the S&C 5800 Series Automatic Switch Control. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below. !DANGER “DANGER” identifies the most serious and immediate hazards which will likely result in serious personal injury or death if instructions, including recommended precautions, are not followed. !WARNING “WARNING” identifies hazards or unsafe practices...

 Open the catalog to page 3
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-4

SAFETY INFORMATION Location of Safety Labels

 Open the catalog to page 4
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-5

DESCRIPTION IntelliTEAM II System 5800 Series Controls with the IntelliTEAM II System let Scada-Mate® Switches, OmniRupter® Automated Switching Systems, Remote Supervisory Vista®, and pad-mounted distribution switches, or a combination of these, form teams that provide fast, fully automatic fault isolation and service restoration. Up to two automatic switch positions of the pad-mounted gear can be utilized, and configured independently, to provide further flexibility for the transfer process. Using peer-to-peer communications and distributed intelligence, team members protect a line segment by...

 Open the catalog to page 5
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-6

Mounting Channel LCD & Scroll Switches Faceplate LEDs & Switches Local Communications Access Port Door Pocket Switch Control Enclosure Door Retainer Switch Interface Connector(s) Faceplate Retainer Figure 1. Switch Control with Enclosure Door Open (S&C 5801 shown) Switch control enclosure (if applicable) – Sturdy, corrosion resistant aluminum box provides weatherproof and tamper-resistant protection for the switch control components. Switch interface connector(s) – Provides a connection point on the bottom of the switch control enclosure for cables carrying sensor data and control/status signals;...

 Open the catalog to page 6
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-7

Universal Communications Mounting Plate Switch Control Electronics Modules Communications Equipment (optional) Grounded AC Outlet Figure 2. Switch Control with Faceplate Open (S&C 5801 shown) Switch control electronics modules – Modularized for easy troubleshooting and replacement. Universal Communications Mounting Plate – A solid base on which the equipment for SCADA and team communications (radio, modem, etc.) is mounted. Communications equipment – The IntelliTEAM II system uses DNP protocol and a radio, modem, or other device for peer-to-peer communication and for 2-way communication between...

 Open the catalog to page 7
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-8

5800 Series Switch Control Features All controls in the S&C 5800 series include the following features: Dependable quality – Electronics manufactured in an ISO 9002-certified plant. Tough and reliable – Designed to withstand the difficult environmental and electrical conditions found in electric distribution applications. Rugged, well-proven core electronics design – Microprocessor, memory, and all related components based on technology developed for S&C’s full range of control products (with over 100,000 units in the field since 1985). Data logging capabilities – Useful for both stand-alone...

 Open the catalog to page 8
S&C 5800 Series Automatic Switch Controls With IntelliTEAM II? Automatic Restoration System-9

Your S&C 5801 switch control also includes special features which customize it for use with overhead switches. These features include: Custom ac voltage and current-signal conditioning – Specifically designed and tested for use with the type of sensors in use. Specialized enclosure wiring – Switch interface connector and internal enclosure wiring matched to the control cable. Switch control shipped ready to install – Control is modular with prewired connectors, and requires no discrete field wiring other than 120 Vac control power. Visual disconnect – Supports the S&C D2 visual disconnect option...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.