Polarimeter Selection Guide
4Pages

{{requestButtons}}

Catalog excerpts

Polarimeter Selection Guide - 1

For Pharmaceutical Applications Two Great Solutions ® ® The Autopol V and Autopol V PLUS ® ® United States Department of Commerce National Institute of Standards and Technology NVLAP LAB CODE: 200898-0 Accreditation to ISO/IEC 17025:2005 The brand of polarimeter used in more labs than any other.* TECHNICAL BULLETIN 928 *Emmes Survey

Open the catalog to page 1
Polarimeter Selection Guide - 2

Two excellent polarimeter choices to satisfy the most stringent pharmaceutical requirements Autopol® V Autopol® V PLUS With Hastelloy™ acid resistance and three rotation NIST calibration standard The Industry Standard Polarimeter The Autopol® V has the validation tools and features to satisfy today’s global pharmaceutical companies, including: instrument level 21CFR Part 11 compliance, NIST traceable calibration standards and a global list of installations. Rudolph Research has thousands of satisfied customers who praise the Autopol® V’s quality, accuracy and reproducibility. Standard...

Open the catalog to page 2
Polarimeter Selection Guide - 3

The Autopol® V and V Plus Use Rudolph’s Exclusive TempTrol™ Electronic Temperature Control System THE AUTOPOL® V PLUS ADVANTAGE The USP <781> requires optical rotation measurements at 25°C ± .5°C (unless another temperature is specified). The European Pharmacopoeia requires optical rotation measurements made at 20° ± .5°C (unless another temperature is specified). • 6m HCl acid resistance: Silco Steel coating on the chamber temperature transfer surface and a Hastelloy measurement cell with NIST certificate certifying optical path length. Whatever your temperature control needs are, the...

Open the catalog to page 3
Polarimeter Selection Guide - 4

Specifications Features Measuring Mode: Optical Rotation, Specific Rotation, Concentration & User-defined Scales Optical Rotation, Specific Rotation, Concentration & User-defined Scales Measuring Scale: Measuring Range: ±89.9° Arc Optical Rotation, ±999.99° Arc Specific Rotation and 0-99.9% Concentration ±89.9° Arc Optical Rotation, ±999.99° Arc Specific Rotation and 0-99.9% Concentration 0.001° Arc Optical Rotation 0.001% Concentration 0.001° Specific Rotation 0.001° Arc Optical Rotation 0.001% Concentration 0.001° Specific Rotation Standard Model Accuracy: (546nm and 589nm): ±0.002° Arc...

Open the catalog to page 4

All Rudolph Research Analytical catalogs and technical brochures

  1. Autopol®

    8 Pages

  2. AlcoTest-Ri

    6 Pages

  3. Verilink Rx

    4 Pages

  4. Autopol V

    4 Pages

  5. Autopol IV

    8 Pages

  6. AutoPol I

    2 Pages

Archived catalogs