Overview: This technical bulletin from Rudolph Research Analytical provides comprehensive information on cells and calibration standards for automatic polarimeters, covering specifications, procedures, and recommendations for use and maintenance.
Temperature Control Solutions: Rudolph offers two temperature control solutions: the patented TempTrol™ technology, which eliminates the need for a water bath and ensures precise temperature measurement within ±0.2°C, and traditional water bath temperature control.
Cell Design and Advantages: The polarimeter cells are designed to minimize air bubbles and enhance measurement stability, featuring stainless steel screw ends with smaller apertures to prevent light disturbance. The design facilitates easy cleaning and maintenance.
Filling and Cleaning Procedures: The cells are designed for easy filling and cleaning, with the Fill Station™ accessory ensuring an air bubble-free sample. Compressed air and acetone are recommended for cleaning.
Calibration Standards: Various sample cells, including TempTrol™, ceramic, and stainless steel options, are available with detailed specifications for each type, including dimensions and sample volumes.
Quartz Calibration Standards: TempTrol™ Quartz Plates allow for temperature control and correction, while standard Quartz Plates allow for temperature correction only. Calibration values are provided for multiple wavelengths, ensuring traceability to NIST standards.
Recommendations: Ceramic quartz polarimeter sample cells are recommended for laboratories working with corrosive samples. The bulletin emphasizes selecting the appropriate cell type for specific applications and offers customer support for selection assistance.
Quartz Plates Overview: Quartz Plates are available in single and three rotation types, calibrated in degrees Arc and degrees ISS/Z. They consist of left (levo) and right (dextro) turning Quartz Plates, with a reported uncertainty of ±0.002° Arc at 589 nm.
Manufacturing Standards: Quartz Control Plates are manufactured to NIST and ICUMSA standards, providing a permanent calibration standard. They meet specific planeness, parallelism, purity, and axis standards, and include a calibration label for 11 wavelengths and a NIST Traceable Certificate.
Sampling Cells: Various sampling cells are offered for different applications, including continuous sampling, pour-in sampling with temperature correction, and micro volumes for HPLC. Options for acid-resistant materials like Ceramic Quartz and Silco Steel are available.
Cell Selection and Compatibility: With over 50 cell options, Rudolph Research Analytical provides solutions for diverse applications. The Autopol® polarimeter accepts sample cells from 10mm to 200mm long, offering increased sensitivity for small rotation solutions.
Calibration and Recalibration: Quartz Control Plates are calibrated by Rudolph Research Analytical and traceable to NIST. Recalibration is recommended every two to three years due to optical stability. TempTrol™ Quartz Plates offer automatic temperature control with compatible polarimeters.
Specifications and Accuracy: Standard rotations and accuracy for Quartz Control Plates are provided at 589 nm, with specific degrees Arc and ISS/Z values. The accuracy is maintained at ±0.002° Arc and ±0.01°Z (ISS).
See more

Catalog excerpts

Cells and Calibration Standards-1

Cells and Calibration Standards Cells, NIST Traceable Calibration Standards and Filling Options for Automatic Polarimeters NVLAP LAB CODE: 200898-0 Accreditation to ISO/IEC 17025:2005 www.rudolphresearch.com/resources/quality

 Open the catalog to page 1
Cells and Calibration Standards-2

Two Temperature Control Solutions 1. atented TempTrol™ Technology P Eliminates the Need for a Water Bath 2. emperature Control With Water Bath T Glass Stopper TempTrol™ heating and cooling transfer surface TempTrol™ cell with mating heating and cooling absorption surface Picture A Temperature is selected via touch screen. Place the TempTrol™ cell in your TempTrol™ equipped Autopol® sample chamber to measure to within ±0.2°C of the USP, EP, JP or BP specified temperature (normally 20°C or 25°C ±0.5°C) Water Inlet NIST  Thermometer As seen above, almost all Rudolph Research Analytical jacketed...

 Open the catalog to page 2
Cells and Calibration Standards-3

Rudolph Research Polarimeter Sample Cells Sample will appear here The sample is injected in upper outlet port. with a Luer Syringe into the lower inlet port as seen here. Rudolph Research Polarimeter Sample Cells are designed to be easily filled and cleaned. When held at the correct angle and filled using the lower inlet port, the cell is filled with almost no possibility of leaving an air bubble in the cell. Filling from the lower inlet port forces any air bubbles up and out of the upper outlet port. Rudolph cells are unlike other manufacturers cells as they are uniquely designed to keep small...

 Open the catalog to page 3
Cells and Calibration Standards-4

Type 40T TempTrol™ Polarimeter Sample Cells: These cells are constructed of stainless steel and Delrin® and come with Luer® fittings at either end of the cell for easy filling with a plastic syringe or pipette. The cells have removable metal collars that allow for easy cleaning and glass cell end replacement. All cells come with Luer® lock and plug stoppers. Select Hastelloy® “H” when working with acids. Select HP for Automation or High Pressure Applications. Select H-SI Hastelloy® and Silco Steel® for a thin glass coating. For laboratories that work with strong acids and bases such as 6 Molar...

 Open the catalog to page 4
Cells and Calibration Standards-5

Type 30J Stainless Steel Jacketed Sample Cells: Type 30 with stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. The cell has a built-in temperature port which allows the temperature sensor system to automatically measure the temperature inside the cell. Type 41T TempTrol™ Flow-Through Sample Cells: Stainless steel funnel and exit tubing. The cell has a built-in temperature port which allows the temperature sensor and temperature control system to automatically measure and control the temperature inside the cell to 20°C, 25°C or any input...

 Open the catalog to page 5
Cells and Calibration Standards-6

NIST Traceable Calibration Standards Picture E TempTrol ™ Quartz Plate Picture F Standard Quartz Plate TempTrol ™ Quartz Plates allow for temperature control and correction. Standard Quartz Plates allow for temperature correction only. Manufactured to NIST and ICUMSA Standards Selecting a Quartz Calibration Standard Rudolph Research Analytical Quartz Control Plates provide a permanent calibration standard for polarimeters and saccharimeters. Every Rudolph calibration standard is manufactured using extremely stable crystalline quartz which is manufactured and polished to specific planeness, parallelism,...

 Open the catalog to page 6
Cells and Calibration Standards-7

Cells That Meet The Most Demanding Applications Selection With over 50 cells to choose from, Rudolph Research Analytical has a cell to meet every application. AUTOPOL® Accepts Sample Cells from 10mm to 200mm Long Some polarimeters accept only special sample cells, with maximum lengths of 100mm. The Autopol® accepts cells up to 200mm long. A 200mm sample cell offers twice the sensitivity when measuring the same solution in a 100mm cell. This additional optical path length is especially useful for solutions having small rotations. For precious samples and essential oils with large optical rotations,...

 Open the catalog to page 7
Cells and Calibration Standards-8

TempTrol™ Quartz Plates indicated by the letter “T” have the facility for automatic temperature control when purchased with a TempTrol™ equipped polarimeter. Every Quartz Control Plate is calibrated by Rudolph Research Analytical and is traceable to the National Institute of Standards and Technology. Certificate of Accreditation to ISO/IEC 17025:2005 is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for: Calibration Laboratories This laboratory is accredited in accordance with the recognized International Standard...

 Open the catalog to page 8

All Rudolph Research Analytical catalogs and technical brochures

  1. Autopol®

    8  Pages

  2. AlcoTest-Ri

    6  Pages

  3. Verilink Rx

    4  Pages

  4. Autopol V

    4  Pages

  5. Autopol IV

    8  Pages

  6. AutoPol I

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.