1. Catalogs
  2. Rudolph Research Analytical
  3. The Autopol ® I, II, and III Automatic Polarimeters
video corpo

The Autopol ® I, II, and III Automatic Polarimeters

The Autopol ® I, II, and III Automatic Polarimeters

The Autopol ® I, II, and III Automatic Polarimeters

Product catalog summary
Overview: Rudolph Research Analytical has been serving its customers with integrity, quality, and innovation for over fifty years. This technical bulletin focuses on the Autopol® I, II, and III automatic polarimeters, which are widely used in various industries including education, food, chemical, and pharmaceutical sectors.
Specifications: The Autopol series offers different models tailored to specific needs and budgets. Each model provides varying levels of accuracy, wavelength options, and temperature control capabilities. The Autopol I is designed for general applications, Autopol II offers greater wavelength flexibility, and Autopol III is suited for pharmaceutical applications with enhanced accuracy.
Features: All models include features such as touchscreen interfaces, automatic calibration, and data storage capabilities. They support multiple measurement modes including optical rotation and specific rotation. The instruments are equipped with tungsten-halogen light sources and can accommodate sample tubes up to 200 mm.
Temperature Control: The bulletin describes three temperature control solutions: basic temperature measurement, control with a water bath, and the patented TempTrol™ technology which eliminates the need for a water bath by using Peltier technology for precise temperature management.
Communication and Data Management: The polarimeters offer versatile communication capabilities, including USB and Ethernet ports for network connections. Measurement data can be saved directly to a network or server, and reports can be customized and printed with company logos.
Accessories and Calibration: Rudolph provides a range of accessories including various cell types and calibration standards. The TempTrol™ system includes a validation cell and optional NIST traceable thermometer for ensuring temperature control accuracy.
Applications: The Autopol series is suitable for a wide range of applications such as university research, flavor and fragrance analysis, and pharmaceutical quality control. Each model is designed to meet specific industry requirements and regulatory standards.
See more

Catalog excerpts

The Autopol ® I, II, and III Automatic Polarimeters-1

For Budget Critical, General Purpose and GLP/GMP Laboratories The Autopol® I, II, and III Automatic Polarimeters United States Department of Commerce National Institute of Standards and Technology NVLAP LAB CODE: 200898-0 Accreditation to ISO/IEC 17025:2005 polarimeter brand used in more labs than any other. Meeting the needs of your industry and application • University Education and Research • Flavor, Fragrance and Essential Oil • Food • Chemical • Pharmaceutical TECHNICAL BULLETIN 932 *Emmes Survey Rudolph Research Analytical serving its customers with Integrity, Quality, and Innovation for over fifty years.

 Open the catalog to page 1
The Autopol ® I, II, and III Automatic Polarimeters-2

Simple Solutions ire in Setup > Method? > Edit Method Name MetfOSine Time Delay Versatile Communication Capability • Connect directly to Rudolphs service department for remote testing and diagnostics via Internet connection. • Connect to any Windows* based printer via USB or direct to the server via Windows* Print Library • Save measurement data direct to your Network/Server Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA ■ Phone: 973-584-1558 ■ Fax: 973-584-5440 ■ E-mail: [email protected] ■ Internet: www.rudolphresearch.com

 Open the catalog to page 2
The Autopol ® I, II, and III Automatic Polarimeters-3

that Best Suits your Application and Budget Autopol I The Autopol I is our entry-level polarimeter model designed for: • University Education • Starch Analysis • Lactose in Milk • Flavors • Chemicals Natural Product Research Invert Sugar Vitamins Fragrance Standard Features: 0.01° Arc Accuracy, 589nm fixed wavelength, built in thermoprobe for temperature measurement, Windows Embedded 7 for direct connection to the network server and flexible USB printing. Optional Features: • TempTrol™ heating and cooling: 15°C – 40°C ±.2°C • AP Accuracy Option: 0.004° Arc Optical Rotation • AP Resolution Option:...

 Open the catalog to page 3
The Autopol ® I, II, and III Automatic Polarimeters-4

Select a Temperature Solution 1. Temperature Measurement Only As shown in Figure A, the Autopol I, II, and III come with a Temperature Probe so that sample temperature can be measured, displayed, and printed. However, if your product requires Temperature control, then we recommend a temperature control solution shown below. For university education and research, starch analysis, invert sugar, flavors, fragrances temperature control is not required and temperature measurement is normally sufficient for these applications. 2. Temperature Control With Water Bath Glass Stopper Rudolph Research Analytical...

 Open the catalog to page 4
The Autopol ® I, II, and III Automatic Polarimeters-5

Select the Accessories to meet your application Selection With over 50 cells to choose from, Rudolph Research Analytical has a cell to meet every application. Rudolph offers cells with volumes as small as 100 micro liters and cell lengths from 10 mm to 200 mm. Rudolph 40T and 316 stainless steel cells come with lifetime warranty against accidental breakage. Autopol I and II The Autopol I and II come standard with Package A, which includes: 2 lamps and a Type 14 center fill glass cell with a 100 mm length and a 6 ml volume. For validation purposes Rudolph recommends a NIST Traceable Calibration...

 Open the catalog to page 5
The Autopol ® I, II, and III Automatic Polarimeters-6

Specifications Markets SPECIFICATIONS Measuring Mode Optical Rotation, Specific Rotation, Concentration, Sugar Degrees, °Z (ISS) Optical Rotation, Specific Rotation, Concentration, Sugar Degrees, °Z (ISS) Degrees Arc Optical Rotation Degrees Arc Optical Rotation 0.01° Arc Optical Rotation, 0.01% Concentration. 0.01 Specific Rotation 0.01° Arc Optical Rotation, 0.01% Concentration, 0.01 Specific Rotation 0.001° Arc Optical Rotation,0.001% Concentration, 0.001 Specific Rotation 0.01° Arc Optical Rotation, 0.03°Z (ISS) Sugar Degrees 0.01° Arc Optical Rotation, 0.03°Z (ISS) Sugar Degrees Resolution:...

 Open the catalog to page 6

All Rudolph Research Analytical catalogs and technical brochures

  1. Autopol®

    8  Pages

  2. AlcoTest-Ri

    6  Pages

  3. Verilink Rx

    4  Pages

  4. Autopol V

    4  Pages

  5. Autopol IV

    8  Pages

  6. AutoPol I

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.