891334

891334

891334

Product catalog summary
Overview: The Sensit HPS - C Series Rationalised mV Output Pressure Transducer is a four-wire, ratiometric device designed for excellent chemical and corrosion resistance. It uses a strain gauge bridge sensor fused to a ceramic diaphragm and is available in gauge or absolute pressure configurations. The transducer is offered in three classes of accuracy and stability, with pressure ranges from 100mbar to 600 bar.
Key Features:
  • Stainless Steel housing
  • Rugged construction
  • Excellent linearity and long-term stability
  • Wide temperature range
  • Rationalised output
Specifications:
  • Class A - High Specification Transducer: Offers a compensated temperature range of -20°C to 125°C, with a thermal zero shift of ±0.01% span/°C from 0 to 100°C and ±0.015% span/°C outside this range. Long-term stability is 0.1% over 12 months.
  • Class B - Industrial Transducer: Compensated temperature range is 0°C to 100°C, with a thermal zero shift of ±0.015% span/°C. Long-term stability is 0.1% over 12 months.
  • Class C - General Purpose/OEM Transducer: Compensated temperature range is 0°C to 80°C, with a thermal zero shift of ±0.04% span/°C. Long-term stability is 0.1% over 12 months.
Options:
  • Pressure Connections: Various BSP and NPT male and female options available.
  • Electrical Connection: Options include IP65 and IP68 rated connections.
  • Housing Material: Standard is 316L Stainless Steel, with other materials available on request.
Mechanical Specification: The transducer can handle a safe over-range pressure of 1.5 times the rated range and a burst pressure of at least 3 times the rated range. Wetted materials include stainless steel, alumina ceramic, and Viton.
Additional Information: For level or depth measurement, the TRIDENT Series of submersible pressure transducers is recommended. Custom solutions are available through the OEM design team.
See more

Catalog excerpts

891334-1

PRESSURE Product Data Sheet Sensit HPS - C Series Rationalised mV Output Pressure Transducer Four wire, ratiometric, mV output transducer offering superb chemical and corrosion resistance. Gauge or Absolute pressure is detected using a four active arm strain gauge bridge sensor, fused to a high-purity ceramic diaphragm. Available in three classes of accuracy and stability specified below, with ranges from 100mbar to 600 bar or scaled to customer requirements. ● ● ● ● ● ● Stainless Steel housing Rugged construction Excellent linearity Excellent long term stability Wide temperature range Rationalised output CLASS A HIGH SPECIFICATION TRANSDUCER Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Long Term Stability Power Supply Dependent on range. ±1mV 0mV ±0.1mV/V ±0.2% of span (best fit straight line) -20oC to 125oC -20oC to 125oC <0 to 100oC, ±0.01% span / oC <0oC & >100oC, ±0.015% span / oC ±0.015% reading/ oC typical 0.1% / 12 months typical 2-10Vdc regulated CLASS C GENERAL PURPOSE/OEM TRANSDUCER Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Long Term Stability Power Supply Dependent on range ±1mV 0mV ±0.1mV/V ±0.25% of span (best fit straight line) 0oC to 80oC -20oC to 125oC ±0.04% span / oC ±0.015% reading / oC typical 0.1% / 12 months typical 2-10Vdc regulated OPTIONS Pressure Connections G1/4” BSP male or female G1/2” BSP male 1/4” NPT male or female 1/2” NPT male Others available on request Electrical Connection IP65 mini plug & socket IP65 large plug & socket IP65 cable & ferrule IP68 glanded cable Others available on request Housing Material 316L Stainless Steel Others available on request CLASS B INDUSTRIAL TRANSDUCER Output Span Output Zero Non Linearity, Hysteresis & Repeatability (NLH) Compensated Temp Range Operating Temp Range Thermal Zero Shift Thermal Span Shift Long Term Stability Power Supply Dependent on range ±1mV 0mV ±0.1mV/V ±0.2% of span (best fit straight line) 0oC to 100oC -20oC to 125oC ±0.015% span / oC ±0.015% reading/ oC typical 0.1% / 12 months typical 2-10Vdc regulated

 Open the catalog to page 1
891334-2

DIMENSIONS (mm) IP65 CABLE & FERRULE 4 Core Black PTFE Cable 4 Core Cable with Vent Tube & Strain Wire Case & Cover Material 316L ST ST Cable Outlet, Sleeved & Bonded Case & Cover Material 316L ST ST Mini DIN Connector IP65 rated to BS EN 60529 Case & Cover Material 316L ST ST DIN 43650 PLUG & SOCKET DIN 43650 Connector Pressure Port Sensor Span Range (mV/V) (bar) Pressure Port Case & Cover Material 316L ST ST Pressure Port * Note: >200 bar, Hexagon 27 A/F and diameter 27 SENSIT pressure transducers are also available with the following outputs: ● ● ● MECHANICAL SPECIFICATION Safe Over-range...

 Open the catalog to page 2

All Roxspur Measurement & Control catalogs and technical brochures

  1. PAAM20

    5  Pages

  2. PAAM15

    4  Pages

  3. 176250

    4  Pages

  4. 182688

    2  Pages

  5. 440274

    2  Pages

  6. 162020

    4  Pages

  7. 689924

    3  Pages

  8. 9121

    2  Pages

  9. 770869

    2  Pages

  10. 871727

    2  Pages

  11. 839632

    2  Pages

  12. 148631

    5  Pages

  13. 601391

    2  Pages

  14. 462734

    2  Pages

  15. 303566

    2  Pages

  16. 857958

    2  Pages

  17. 240810

    4  Pages

  18. 302921

    4  Pages

  19. 573867

    4  Pages

  20. 665403

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.