video corpo

Rotronic Catalogue RMS
40Pages

{{requestButtons}}

Catalog excerpts

Rotronic Catalogue RMS - 1

Important measurement data just a click away! With the most flexible continuous Monitoring System Data security Contract Modules

Open the catalog to page 1
Rotronic Catalogue RMS - 2

Rotronic Monitoring System RMS – ROTRONIC MONITORING SYSTEM The Rotronic continuous Monitoring System allows users to monitor anything from anywhere using an on-premise or cloud (SaaS) solution. Strongly regulated applications • Fridges • Cold rooms • Freezers • Transport with dry ice • Cryogenics with nitrogen tanks • Blood banks • Clean rooms • Warehouses Less regulated applications such as: • Museums • Archives • Storage areas • And much more... Watch the short Explain-it Movie Customize your own RMS Architectu

Open the catalog to page 2
Rotronic Catalogue RMS - 3

Rotronic Monitoring System Multiple parameter monitoring RMS monitors various parameters to ensure that the environment meets the required specifications for any application. 1. Digital probes give acces to a complete audit trail and easy digital calibration thanks to the probe hot swap possibility: • Relative humidity • Temperature • Differential pressure 2. Rotronic offers range of analog probes that can be integrated into the monitoring system: • NTC temperature probes • Pt100 temperature probes • CO2 probes for incubators (0...20%) 3. Other inputs and outputs for third party devices...

Open the catalog to page 3
Rotronic Catalogue RMS - 4

Rotronic Monitoring System Example: LoRa-Geräte über die API-Funktion. 4. The integration of 3rd party digital devices is possible via multiple methods: • MODBUS TCP: If the MODBUS map is available, then it is possible to integrate most MODBUS TCP devices. • API: The RMS software has an API function to integrate data from 3rd party devices. 5. Data collected with RMS can be extracted via multiple methods: • Via the RMS interface, extract selected data via .pdf, .csv or JSON. • Automated reporting is available for .pdf documents. • With the API, data can be exported via JSON. • The...

Open the catalog to page 4
Rotronic Catalogue RMS - 5

Rotronic Monitoring System Wireless or wired secure data communication 1. Wireless: • Data stored on the logger with a battery backup and 24V power supply • Redundant or parallel operation with various gateways • Decrease wiring costs • No more looking for errors in cabling • Projects accomplished faster due to no cable requirements • Easy to relocated physical measuring points • Fast and easy implementation of new measuring points • Monitor mobile equipment • 868 or 915 MHz 2. Wired: • Data stored on the logger with a backup battery, PoE and 24V power supply • No loss of communication for...

Open the catalog to page 5
Rotronic Catalogue RMS - 6

Rotronic Monitoring System Compliance 1. Validatable software 2. FDA CFR 21 Part 11 compliant 3. EU 11 compliant 4. Developed based upon the GAMP©5 recommendations 5. Complete GxP documentation (from the URS to the IQ / OQ / PQ) Real time monitoring and alarming The RMS software will inform you in real time via E-Mail, SMS and telephone call should a measurement point be out of limits! Automatic reporting allow for a hassle free solution and a quick login via mobile phone, tablet, PC or laptop will give you either a chart, table or a layout overview of the current situation, with short cuts...

Open the catalog to page 6
Rotronic Catalogue RMS - 7

Rotronic Monitoring System Scalable – prefect for single points in small installations to thousands of points in worldwide installations Automatic report generation Integration of Rotronic and any third party hardware – analog and digital Automatic validation scripts – for fast and effective OQ validation Continuously developing based around customer feedback Create custom dashboards per user FDA 21 CFR Part 11 & EU 11 complaint GAMP©5 conform for GxP applications Additional Features • Calibrate all of your measuring points, possibility to adjust all of the Rotronic devices • Archive all...

Open the catalog to page 7
Rotronic Catalogue RMS - 8

Rotronic Monitoring System System Overview RMS offers different views/tabs to present your system data, customised to your needs. • Chart – measured values graphically and numerically and direct notification status • Table – measured values numerically and various other data • Layout – measured values numerically with placement in a room layout • Dashboard – individual dashboard for each and every user • Events – audit logs, alarms, warnings and system messages Chart view 4 Upload your company logo 1 Group information by location, room… 2 Real-time measurement value and live status 3 4...

Open the catalog to page 8
Rotronic Catalogue RMS - 9

Rotronic Monitoring System 3 Real time camera view (mouse over) Mouse over detailed measurement point 1 Standard measurement point overview 2 Mouse over IP camera for a snap shot of the current situation 3 Dashboard view: user defined Events view (audit trail) 3 Define the notifications shown in the audit trail 1 See the actual status and user inputs of each individual event 2 Filter the audit trail based upon your requirements 3

Open the catalog to page 9
Rotronic Catalogue RMS - 10

Rotronic Monitoring System DATACENTER IT risk d certifie RMS Database Security When purchasing the RMS SaaS solution, Rotronic works together with the company 4Net. They provide a virtual data centre for the Rotronic Monitoring System server and database. 4Net uses the Interxion data centre. Interxion’s Zurich data centre provides an ultra-secure, known location for storing and processing data in line with Swiss data protection regulations. Like all Interxion data centres, Zurich operates in full accordance with the ITILv3 framework and has ISO 27001 and ISO 22301 certification. Their...

Open the catalog to page 10
Rotronic Catalogue RMS - 11

Rotronic Monitoring System Rotronic Monitoring System alarm protocols were set up to ensure that critical alarms cannot be missed. Notifications can be triggered based upon the risk level. Four levels of alarming are available, activation is based on the defined risk: • Reminder for events that are non-urgent: – Low battery (device) – Simulator connected (measuring point) – Reminder that a calibration is due – Data gap after downloading missing measured values • Warning for measured values that are out of limit (measuring point) • Alarming for measured values that are out of limit...

Open the catalog to page 11

All ROTRONIC AG catalogs and technical brochures

Archived catalogs

  1. HC2A

    4 Pages

  2. AirChip 3000

    45 Pages

  3. HygroFlex 6

    4 Pages

  4. Water Activity

    12 Pages

  5. AC3011

    2 Pages

  6. HygroPalm23

    4 Pages

  7. CO2 Display

    4 Pages

  8. XB OEM

    4 Pages

  9. HygroClip XD

    2 Pages