Group: Process Sensing Technologies (PST)
Catalog excerpts
Solutions for Measurement & Monitoring of Various Parameters
Open the catalog to page 1ABOUT ROTRONIC Rotronic measuring instruments: precision at the highest level Based in Switzerland and established in 1965, Rotronic offers a wide range of handheld instruments, transmitters, (industrial) probes, data loggers, OEM products and monitoring systems. A world leader in relative humidity and temperature measurement, our portfolio also includes solutions for water activity, CO2 and differential pressure. We thus cover a wide range of applications from the pharmaceutical and food industries to HVAC and meteorology. Rotronic Monitoring System: modular, flexible and reliable The...
Open the catalog to page 2Humidity and Temperature Probes & Filters Water activity Data loggers Handheld instruments Rotronic Monitoring System – RMS Data loggers Differential pressure Consultation, Validation, Calibration Data Loggers Seminar, Repair Handheld instrument Equipment hire Technical data Theory Measurement parameters: fundamentals
Open the catalog to page 3Differential pressure Rotronic Monitoring System – RMS Video Humidity Interested? Then scan the QR code!
Open the catalog to page 4Humidity and Temperature Probes & Filters rolronic Humidity and Temperature Probes & Filters rolronic Standard and high precision probes HC2A-S / HC2A-S-HH / HC2A-S3 and HC2A-SH/HC2A-S3H The HC2A-S / HC2A-S-HH / HC2A-S3 is the most versatile probe from Rotronic and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point. The HC2A-SH/HC2A-S3H fulfills the highest demands for measuring accuracy. APPLICATIONS HVAC, food industry, building services equipment, paper, textile and pharmaceutical industries. FEATURES • Accuracy: standard...
Open the catalog to page 5Humidity and Temperature Probes & Filters rolronic Industrial probes, steel The HC2A-SM is the robust probe from Rotronic for harsh environments and adds to the wide product portfolio. It measures humidity and temperature and calculates the dew/frost point. APPLICATIONS Food, paper, textile, pharmaceutical and cosmetic industries. FEATURES • Accuracy: ±0.8 %RH, ±0.1 K, at 10...30 °C • Range of application: -50...100 °C / 0...100 %RH • Digital interface (UART) and scalable analog outputs, 0.1 V • Standard analog output scaling: 0.1 V = -40.60 °C / 0.100 %RH • Adjusted at 23 °C and 10, 35, 80...
Open the catalog to page 6Humidity and Temperature Probes & Filters rolronic Humidity and Temperature Probes & Filters rolronic Industrial cable probes The Rotronic industrial probe is especially suitable for high temperatures and demanding industrial environments. It measures humidity and temperature and calculates the dew/frost point. APPLICATIONS Production environments, high temperatures, industrial manufacturing, drying processes, climate chambers. FEATURES • Accuracy: ±0.8 %RH, ±0.1 K, at 10...30 °C • Range of application: -100...200 °0 (HC2-HK40)/ 0...100 %RH • Digital interface (UART) and scalable analog...
Open the catalog to page 7Humidity and Temperature Probes & Filters rolronic Humidity and Temperature Probes & Filters rolronic Industrial cable probes, steel The metal industrial probe is especially suitable for high temperatures, demanding industrial environments and applications where hygiene plays an important role. The probe measures humidity and temperature and calculates the dew/frost point. APPLICATIONS Food and pharmaceutical production, drying processes, industrial manufacturing. FEATURES • Accuracy: ±0.8 %RH, ±0.1 K, at 10...30 °C • Range of application: -100...200 °0, (screw-in probe; -100...200 °0) /...
Open the catalog to page 8Humidity and Temperature Probes & Filters rolronic High temperature handheld probes The handheld probe is especially suitable for portable measurements of high temperatures. It measures humidity and temperature and calculates the dew/frost point. APPLICATIONS Climate and temperature chambers, dryers, air ducts. FEATURES • Accuracy: ±0.8 %RH, ±0.1 K, at 10...30 °C • Range of application: -100...170 °C/200 °G / 0...100 %RH • Digital interface (UART) and scalable analog outputs, 0.1 V • Standard output scaling: 0.1 V = -40.60 °C / 0.100 %RH • Adjusted at 23 °C and 10, 35, 80 %RH Order code...
Open the catalog to page 9Humidity and Temperature Probes & Filters rolronic Humidity and Temperature Probes & Filters rolronic HygroWin USB probe The USB probe measures humidity and temperature. It is ideal for basic monitoring applications. The HW4 Software PC software is included. APPLICATIONS Residential and office. FEATURES • Accuracy: ±2 %RH, ±0.3 K, at 10...30 °C • Connects directly to a PC on a USB port • Range of application: -40...85 °C / 0...100 %RH • Adjusted at 23 °C and 10, 35, 80 %RH • Factory adjustment certificate • Calibration device ER-15 • HW4 software (download) • Humidity standard for...
Open the catalog to page 10Humidity and Temperature Probes & Filters rolronic Miniature probes The miniature probe is used for humidity and temperature measurement in confined spaces. It also calculates the dew/frost point and can be installed discretely. The 4 mm probe has a spike tip for insertion in walls. APPLICATIONS Museums, glass cabinets, building material tests, automotive and aviation industries, testing laboratories, paper, textile and pharmaceutical industries. FEATURES • Accuracy: ±1.5 %RH, ±0.3 K, at 10...30 °C • Range of application: -40...85 °C / 0...100 %RH • Digital interface (UART) and scalable...
Open the catalog to page 11Humidity and Temperature Probes & Filters rolronic Insertion probes 0 5 mm / 10 mm The insertion probe is suitable for measurement in dust-free (P05) or dusty (HP28/50) bulk materials, bricks, concrete, etc. It measures humidity and temperature and calculates the dew/frost point. APPLICATIONS Water activity measurement Portable measuring units with handheld instruments and data loggers. FEATURES • Accuracy: ±0.8/1.5 %RH, ±0.1/0.3 K, at 10...30 °C • Range of application: -40...85 °C / 0...100 %RH • Digital interface (UART) • Standard output scaling: 0.1 V = -40.60 °C / 0.100 %RH • Adjusted...
Open the catalog to page 12All ROTRONIC AG catalogs and technical brochures
-
HYGROPALM - HP32
3 Pages
-
HYGROFLEX1
2 Pages
-
HC2A
4 Pages
-
T10-XXXX NTC
2 Pages
-
Rotronic Catalogue 2023
153 Pages
Archived catalogs
-
Rotronic Catalogue RMS
40 Pages
-
Rotronic Product Catalogue 2022
156 Pages
-
HC2A
4 Pages
-
RMS ACCESSORIES
4 Pages
-
RMS – ROTRONIC MONITORING SYSTEM
48 Pages
-
HygroGen2-S/XL
6 Pages
-
AirChip 3000
45 Pages
-
HygroFlex 6
4 Pages
-
HygroFlex1 - HF1 Transmitter
2 Pages
-
RMS-Mini Wireless Logger
2 Pages
-
RMS-Data Logger
2 Pages
-
TP31-S Folding Thermometer
2 Pages
-
TP31-IR Infrared Thermometer
2 Pages
-
BL-1D/HL-1D/TL-1D
2 Pages
-
HygroMer IN-1
2 Pages
-
HygroMet MP102H / 402H
4 Pages
-
Water Activity
12 Pages
-
E-T-AC3000-DF-V1-12
17 Pages
-
NSP-POM-FD2 Filter
1 Pages
-
AC3021 Distribution Box
2 Pages
-
AC3011
2 Pages
-
Clean Room Panel - CRP5
6 Pages
-
HygroClip2 Datasheet
4 Pages
-
HygroFlex3 Datasheet
4 Pages
-
HygroFlex4 Datasheet
4 Pages
-
HygroWin (HC2-WIN-USB)
2 Pages
-
HygroPalm21/22
4 Pages
-
HygroPalm23
4 Pages
-
HygroFlex7 Transmitter
4 Pages
-
HygroFlex8 Transmitter
4 Pages
-
HygroLog HL-NT Data Logger
4 Pages
-
HygroGen2 Humidity Generator
6 Pages
-
Wireless systems
6 Pages
-
CO2 Transmitter
6 Pages
-
HC2-Ix25 Flush Mount Probes
2 Pages
-
HygroFlex5 Datasheet
4 Pages
-
CO2 Display
4 Pages
-
XB OEM
4 Pages
-
HygroClip XD
2 Pages
-
HC2-ROPCB OEM
2 Pages
-
Measurement news 2014
16 Pages
-
Product Overview
16 Pages