CO2 Display - 1

MONITORING OF INDOOR AIR QUALITY • Measures and records CO2, relative humidity and temperature • Accuracy ±2.5 %RH / ±0.3 K / ±30 ppm + 5% of measured value • ROTRONIC HYGROMER® IN-1 humidity sensor • 18,000 data point memory for CO2, humidity and temperature values • Display of date and time • Adjustable, visual CO2 indicator • Large, easy-to-read display • USB access for data download

Open the catalog to page 1
CO2 Display - 2

THE MAIN ADVANTAGES AT A GLANCE The wall-mounted or bench-top CO2 display is the latest development of an inexpensive display unit that simultaneously measures and records CO2, humidity and temperature. Equipped with the field-tested ROTRONIC HYGROMER® IN-1 humidity sensor, this instrument offers unbeatable value for money. The instrument can be configured directly with buttons and stored data can be exported to a USB stick for analysis with the free ROTRONIC software package SW21. TEMPERATURE HUMIDITY □AY MDMTH YEAR HOUR MIN • Display for mounting on walls • Data recording function •...

Open the catalog to page 2
CO2 Display - 3

APPLICATIONS Indoor Air Quality Classrooms, Kindergartens Meeting Rooms, Open-Plan Offices Shopping Centers, Fitness Studios PRINCIPLES The wall-mounted or bench-top CO2 display evaluates the quality of air with a combined measurement of CO2, humidity and temperature. A high concentration of carbon dioxide can develop quickly when closed rooms with decient ventilation are lled with people. Carbon dioxide (CO2) is a colorless and odorless gas that exists in the earth’s atmosphere and which is dangerous in high concentrations. The proportion of CO2 in natural ambient air is about 0.04 % or...

Open the catalog to page 3
CO2 Display - 4

T E C H N I C A L I N F O R M AT I O N General Type Parameters Range of application Power supply Clock Alarm/Indicator Wall or bench-top display CO2, relative humidity and temperature 0…50 °C / 0…95 %RH, non-condensing AC adapter 12 VDC Real time clock Adjustable for CO2 measurement Technical Information / Functions Current consumption Warm-up time Memory capacity 700 mA (max) <1 min. 18,000 values with time stamp, automatic recording (%RH / °C / ppm) CO2 Measurement Measurement principle Measurement range Accuracy at 23 °C ±5 K 130 Response time Adjustment points Pressure dependence Null...

Open the catalog to page 4