1. Catalogs
  2. ROTOTEC SPA
  3. SEWAGE TREATMENT CATALOGUE AND PRICE LIST

SEWAGE TREATMENT CATALOGUE AND PRICE LIST

SEWAGE TREATMENT CATALOGUE AND PRICE LIST
1 / 216 PagesView full catalog

SEWAGE TREATMENT CATALOGUE AND PRICE LIST

Product catalog summary
Company Overview
Rototec S.p.A., part of the System Group, specializes in producing corrugated and smooth tanks using rotational moulding technology. Established in 2000, the company focuses on high-performance and reliable treatment systems, adhering to European standards. Rototec emphasizes environmental protection and regulatory compliance, utilizing both digital and traditional communication channels for outreach and education.
Services Offered
  • Training meetings and technical seminars
  • Design support with plant configuration software and BIM libraries
  • Prompt delivery and on-site technical support
  • Comprehensive after-sales service
System Group Background
Founded by Alvaro Boscarini, the System Group began with Centraltubi in 1979 and expanded to include several companies specializing in various piping and fitting solutions. The group has a strong presence in Europe with facilities in Spain, France, and Romania.
Sewage Division Overview
  • Includes products like grease separators, Imhoff biological tanks, and sewage treatment plants.
  • Focus on high-efficiency secondary treatments and activated sludge plants.
Population Equivalent Calculation
This concept helps express the load on a treatment plant in terms comparable to domestic users, based on organic load (BOD5). Various coefficients are provided for different types of users, such as residential buildings, offices, and restaurants.
Grease Separators
  • Designed to remove oils, foams, and greases from grey water.
  • CE marked and compliant with UNI EN 1825-1 standards.
  • Available in various models, including above-ground and under-sink options.
Technical Specifications
Grease separators function as stilling tanks, separating substances with specific weights less than water. They are crucial for preventing the accumulation of putrescible substances in sewerage pipes, which can hinder biological treatment processes.
Specifications and Design
Rototec gravity grease separators are designed with a polyethylene tank divided into three compartments: an inlet zone to reduce turbulence, a separation zone for grease and solids, and an outlet zone for treated effluent. The system is effective when the temperature is around 20°C, ensuring optimal grease separation. The separators are certified under UNI-EN 1825-1, guaranteeing a minimum retention time of 4 minutes at peak flow.
Use and Maintenance
Regular maintenance is crucial to prevent efficiency loss due to accumulated materials. It is recommended to remove surface crusts and sludge periodically to maintain effective volume and prevent septic conditions. Maintenance should be performed by specialists to avoid bad odors and ensure system efficiency.
Prohibitions and Warnings
Do not use toxic substances or allow rainwater into the system. Ensure drains have siphons, pipes have a sufficient gradient, and biogas vent pipes are connected. After maintenance, refill the tank with clean water.
Management
Inspect the grease separator every 1-2 months and clean every 6-12 months, depending on the waste load. Licensed waste disposal companies should be contacted for sludge removal.
Imhoff Biological Tanks
These tanks consist of two compartments for sedimentation and digestion. They are used for primary sewage treatment and are CE marked under UNI EN 12566-3. The tanks are designed for homes with a range of 2 to 40 Population Equivalent (PE) and offer high sewage treatment efficiency.
Technical Characteristics
The Imhoff tanks facilitate sedimentation and anaerobic digestion, reducing pollutants like BOD5, COD, and suspended solids. They require a start-up phase for bacterial flora development and periodic inspections to maintain efficiency.
Installation and Maintenance
Install directly on the sewage line, preferably with a grease separator for grey water pre-treatment. Use bio-activators to expedite biological processes and schedule regular inspections and sludge removal.
Prohibitions and Warnings
Avoid toxic substances and ensure proper installation with siphons and gradients. After maintenance, refill with clean water and adhere to safety regulations during operations.
Specifications and Technical Characteristics
Septic tanks are reliable devices for the primary treatment of sewage, particularly for small communities. They operate passively, are stable, simple, and cost-effective. The tank design slows sewage flow, allowing sedimentable solids to separate and triggering anaerobic fermentation, which reduces suspended solids. The effluent is conditioned with limited solid concentration.
Use
Septic tanks are primarily used for domestic sewage treatment from toilets, with a daily hydraulic load of 200 liters per population equivalent (PE).
Product Certification
Rototec biological septic tanks are CE marked and certified under UNI EN 12566-1, excluding modular, 2-chamber, and 3-chamber tanks. They meet requirements for hydraulic efficiency, watertightness, nominal capacity, structural behavior, and design.
Technical Characteristics
Septic tanks facilitate sedimentation and anaerobic processes, reducing organic substances and storing separated materials. Compartmentation enhances treatment efficiency by retaining suspended solids in the first chamber. Regular inspections and sludge removal are necessary to prevent malodorous emissions and maintain treatment quality.
Prohibitions and Warnings
Avoid using toxic substances and ensure only biodegradable products are used. Do not flush non-toilet paper materials or allow rainwater into the system. Ensure proper pipe slope and biogas venting.
Management
Inspect the septic tank 1 to 4 times a year, removing sludge as needed. Use Rototec Bio-activator to enhance biological processes and reduce sludge removal frequency.
Depuro One Sewage Treatment Plants
Depuro One is a fully biological treatment system for domestic effluent, consisting of a primary sedimentation tank and an oxidation tank. It is CE marked and certified under UNI EN 12566-3. The system offers high sewage treatment efficiency, reduced management costs, and easy installation and maintenance.
Technical Characteristics
Depuro One utilizes both anaerobic and aerobic processes to oxidize organic substrates, transforming nitrogenous compounds into non-polluting forms. It includes a primary sedimentation tank and an oxidation tank with recirculation, offering a wide range of models for different population equivalents.
Overview: The document provides a detailed technical description of the DEPURO PLUS sewage treatment system, which is designed for domestic effluent treatment. It outlines the system's components, processes, maintenance requirements, and technical specifications.
System Components:
  • TANK 1: An Imhoff type biological tank with two compartments for sedimentation and anaerobic digestion. It reduces solid and organic components by over 50%.
  • TANK 2: An aerated adhered biomass trickle filter with high surface area plastic media for bacterial growth, facilitating aerobic treatment.
  • TANK 3: A second Imhoff tank for sedimentation of surplus sludge, which is recirculated to Tank 1.
Processes:
  • Gravity Separation: Sedimentable solids settle in Tank 1, while lighter components like oils accumulate at the top.
  • Anaerobic Digestion: Occurs in Tank 1, reducing solids and organic matter.
  • Aerobic Treatment: In Tank 2, oxygenation supports bacterial growth for pollutant oxidation.
  • Sludge Recirculation: Surplus sludge from Tank 3 is returned to Tank 1.
Maintenance and Use:
  • Regular inspections (1-2 times a year) and sludge removal every 6-8 months are recommended.
  • Use of Rototec BIO-ACTIVATOR is advised to enhance biological processes and reduce malodorous emissions.
  • Ensure proper functioning of sludge recirculation and clean internal surfaces to prevent blockages.
Technical Specifications:
  • CE marked and certified under UNI EN 12566-3 standards.
  • High treatment efficiency with pollutant reduction rates: COD 92%, BOD5 95%, SS 96%, Ntot 57%.
  • Available in models for 3 to 45 Population Equivalent (PE).
Prohibitions and Warnings:
  • Avoid using toxic substances and ensure only biodegradable products are used.
  • Do not flush inappropriate materials or drain rainwater into the system.
  • Ensure proper pipe slope and biogas venting.
Management Guidelines:
  • Regular checks on sediment levels and blower functionality are necessary.
  • Contact licensed waste disposal companies for sludge extraction and cleaning.
Overview: The document provides detailed technical specifications, maintenance procedures, and operational guidelines for sewage treatment plants, specifically focusing on the DEPURO PLUS+ system and activated sludge plants.
Tank Maintenance:
  • Tank 2: Regular inspection is required to ensure the trickle filter is functioning properly. The filter media should have a thin layer of light brown sludge. If the sludge is darker or covers the media completely, the tank needs pumping every 6-8 months.
  • Tank 3: Excess sediment can lead to anaerobic digestion, causing biogas production and odor. Regular cleaning and sludge removal are necessary to maintain effluent quality.
Prohibitions and Warnings:
  • Avoid using toxic substances and ensure only biodegradable products are used.
  • Do not flush non-toilet paper materials or allow rainwater into the system.
  • Ensure proper siphon and gradient in drains, and maintain biogas vent connections.
Management and Maintenance:
  • Regular inspections and cleaning of tanks and components are required, with specific intervals for different tasks (e.g., monthly blower checks, bi-annual sludge removal).
  • Licensed waste disposal companies should be contacted for sludge removal and cleaning operations.
Technical Specifications:
  • The document details the installation and operation of diaphragm-type air compressors used in the aeration system, emphasizing energy efficiency and minimal maintenance.
  • Installation guidelines for blowers and pipe diffusers are provided, including environmental considerations and connection instructions.
Activated Sludge Plants:
  • These plants use bacterial colonies to treat sewage by consuming organic material. They require a specific oxygen concentration, maintained by an aeration system with submerged diffusers.
  • The document includes specifications for various models, detailing dimensions, capacities, and operational parameters.
Efficiency and Use:
  • The treatment systems are designed to meet specific effluent concentration standards, with parameters for COD, BOD5, and SS outlined.
  • Activated sludge plants are suitable for secondary treatment of domestic sewage, with daily hydraulic load specifications provided.
Overview: The document provides a comprehensive guide on the use, specifications, and maintenance of activated sludge plants, which are used for the treatment of biodegradable organic material in sewage. These plants utilize aerobic bacteria to degrade organic loads, ensuring the purification of wastewater.
Specifications: Activated sludge plants are designed for primary and secondary treatment of degreased domestic sewage. They operate with high concentrations of aerobic bacteria that consume biodegradable material, facilitated by an aeration system with submerged diffusers. The plants are sized based on sludge load and volumetric load, with configurations for prolonged aeration and low-load scenarios.
Technical Characteristics: The plants ensure the total degradation of organic loads through chemical, physical, and biological processes. The aeration system disperses fine air bubbles to maintain oxygen levels and mix solids in suspension. The sludge load is kept below specific thresholds to optimize the degradation process.
Use and Maintenance: The document outlines the importance of installing a grease separator upstream and maintaining aeration during use. The plant requires 10-15 days to reach normal operation, which can be expedited with biomass activators. Regular inspections and maintenance, such as checking blower operation and cleaning sludge, are necessary.
Prohibitions and Warnings: Users are advised against using toxic substances and draining rainwater into the system. Proper installation and maintenance practices, including ensuring adequate pipe slopes and biogas venting, are emphasized.
Management: Regular inspections and maintenance schedules are provided, including blower checks and sludge extraction. The document also details the installation and operation of blowers and diffusers, highlighting energy efficiency and noise reduction features.
Accessories: The plants come with diaphragm-type air compressors and plate diffusers designed for efficient air distribution and minimal maintenance. Installation guidelines and operational warnings are provided to ensure optimal performance.
Trickle Filters: The document briefly mentions trickle filters as part of the sewage treatment system, describing their role in supporting aerobic bacteria for effluent treatment.
Overview: This document provides detailed specifications and operational guidelines for anaerobic and aerobic trickle filters used in the secondary treatment of domestic sewage. The focus is on ensuring efficient purification through biological processes facilitated by specialized filter media.
Specifications:
  • The trickle filters are biological reactors where microorganisms develop on filter media to purify effluent.
  • Effluent distribution is uniform to maximize contact with the biological film.
  • Daily hydraulic load is specified at 200 l/PE, with flexibility for different loads.
Technical Characteristics:
  • Anaerobic trickle filters operate without dissolved oxygen, while aerobic filters use oxygen supplied by a blower.
  • Filter media is made of polypropylene spheres providing a large surface area (140 m2/m3).
  • Trickle filters are designed for medium-low organic load factors to ensure safety and minimal sludge production.
Installation and Maintenance:
  • Blowers should be installed in a ventilated, non-corrosive environment, with specific guidelines for distance and positioning.
  • Blowers must operate continuously for the first 2-3 months, then can be timed for efficiency.
  • Regular maintenance includes checking blower operation and cleaning filters every few months.
Performance and Efficiency:
  • The system ensures effluent concentrations meet specified limits for COD, BOD5, and SS.
  • Plate diffusers are used for air distribution, minimizing blockages and ensuring high airflow.
Accessories and Components:
  • Includes diaphragm type air compressors and microbored rubber diffusers for optimal oxygenation.
  • Components are designed for durability and minimal maintenance.
Overview: The document provides detailed technical information on the operation, maintenance, and specifications of high-efficiency secondary wastewater treatment systems, specifically focusing on anaerobic trickle filters and activated sludge plants with sludge recirculation.
Specifications: The systems are designed to achieve nearly 100% removal of organic load and suspended solids, with significant reductions in nitrogen and phosphorus levels. The treatment process involves anaerobic trickle filters and activated sludge plants, utilizing polypropylene fill material to maximize microorganism contact with effluent.
Procedures: Regular inspections and maintenance are crucial. Trickle filters should be inspected every 12 months, while activated sludge plants require more frequent checks, every 6 to 12 months. Maintenance includes cleaning sludge, checking blower operations, and ensuring proper air supply.
Prohibitions and Warnings: Toxic substances like bleach and solvents should not be used. Rainwater must not be drained into the system. Proper installation and maintenance practices, such as ensuring pipe slopes and biogas vent connections, are emphasized.
Management: The frequency of maintenance operations depends on the organic load. Regular checks and cleaning of components like blowers and diffusers are necessary to maintain system efficiency.
Technical Characteristics: The systems use anaerobic and aerobic processes to treat domestic sewage, with options for effluent reuse in irrigation, subject to local regulations. The document includes detailed specifications for various models, indicating dimensions, capacities, and operational parameters.
Installation and Use: Proper installation involves using grease separators and Imhoff tanks upstream. The systems require a start-up period of 10-15 days, which can be expedited with bioactivators.
Overview: The document provides detailed technical specifications and operational guidelines for sewage treatment systems, specifically focusing on the IFABLOK, ANABLOK, and BIOBLOK models. These systems are designed for the primary and secondary treatment of domestic sewage using various tank models such as Nanotank, Minitank, and Infinitank.
Specifications: The treatment plants ensure the final effluent concentrations meet specific parameters if the inlet wastewater has typical domestic sewage characteristics. The systems are designed to handle a daily hydraulic load of 200 liters per population equivalent (PE), with the possibility of adjusting for different loads.
System Components:
  • Aeration System: Utilizes submerged diffusers to disperse fine air bubbles, ensuring sufficient oxygen concentration and mixing of solids.
  • Sedimentation and Sludge Digestion: Involves a stilling area where solids settle, and bacterial flora transforms putrescible material into inert sludge, carbon dioxide, and water.
  • Filter Media: Made of plastic bulk fill material, providing a large surface area for anaerobic bacteria development.
Models and Capacities: The document lists various models with specifications such as length, diameter, height, inlet/outlet pipe dimensions, sedimentation volume, and filter volume. Each model is designed to accommodate different population equivalents.
Installation and Maintenance:
  • Installation: Includes diagrams for proper setup, emphasizing the importance of uniform effluent distribution and adequate oxygenation.
  • Maintenance: Regular inspections (1-4 times a year) are recommended to prevent excessive sludge accumulation and ensure efficient operation. The use of Rototec Bio-activator is suggested to enhance biological processes.
Prohibitions and Warnings:
  • Avoid using toxic substances and ensure only biodegradable products are used.
  • Do not flush non-toilet paper materials or allow rainwater into the system.
  • Ensure proper pipe slope and connect biogas vent pipes as per installation guidelines.
Overview: This document provides technical specifications, procedures, and maintenance guidelines for wastewater treatment systems, focusing on primary sedimentation, activated sludge systems, anaerobic percolating filters, and associated accessories.
Primary Sedimentation Management: The frequency of operations depends on the incoming organic load. Regular inspections and sludge removal are necessary, with licensed waste disposal companies recommended for sludge extraction.
Activated Sludge Systems: These systems utilize bacterial colonies to degrade organic material. Key processes include chemical oxidation, physical removal of solids, and biological assimilation. Proper aeration is crucial, and the system requires a grease separator upstream. Maintenance includes regular inspections, blower checks, and sludge removal.
Anaerobic Percolating Filters: These filters use a biological reactor with filter media to purify effluent. They require sedimentation treatment upstream and occasional cleaning to prevent clogging. The use of bio-activators can expedite biological processes.
Prohibitions and Warnings: Avoid using toxic substances and ensure proper drainage and pipe slope. Maintenance operations must comply with safety regulations.
Accessories: Includes side channel compressors, membrane air diffusers, and pipe diffusers. These components aid in aeration and require minimal maintenance. Blowers should operate continuously initially, then can be timed.
Grit Separators: Used for mechanical pretreatment to remove heavy substances from runoff. They are essential for primary treatment of rainwater and runoff from various surfaces.
Oil Separators: These systems separate oils and heavy sediments from effluent, ensuring proper treatment and accumulation in designated areas.
Coalescing Filter Overview
The coalescing filter is a fine micro-bubble polyurethane filter encased in a stainless steel grid. It functions by aggregating fine oil particles in effluents into larger droplets, which then separate and rise to the surface.
Installation and Use
The installation diagram includes components such as a sampling chamber, coalescing filter type oil separator, and a recommended grit separator. These systems are used for treating surface drainage water from areas like car parks and garages.
Technical Characteristics
Oil separators with coalescing filters enhance the removal of light substances like oils and hydrocarbons. They are recommended where strict discharge limits are in place. A grit separator is advised upstream to prevent clogging.
Product Certification
Rototec oil separators are CE marked and comply with UNI EN 858-1 standards, ensuring watertightness, structural stability, and other functional requirements.
Maintenance and Management
Regular inspections and cleaning are necessary to maintain efficiency. This includes removing accumulated pollutants and washing the sponge support. Maintenance frequency depends on oil and grease levels and rainfall.
Warnings and Prohibitions
Do not use toxic substances like bleach or solvents. Ensure drains have a siphon and pipes have adequate slope. Follow safety regulations during maintenance.
Specifications and Models
The document provides detailed specifications for various models, including dimensions, capacities, and recommended applications for different hardstanding areas.
Overview: The document provides detailed technical specifications and maintenance procedures for Rototec's continuous stormwater runoff treatment plants and balancing tanks. These systems are designed to treat stormwater runoff from impermeable surfaces, such as industrial areas and service stations, which may be contaminated with oils, hydrocarbons, and other pollutants.
Specifications: The treatment plants can handle areas up to 27,000 m² and flow rates up to 150 l/s. They include grit separators and coalescing filter type oil separators, certified under UNI EN 858-1 standards. The systems are CE-marked, ensuring compliance with design, performance, and quality control standards.
Technical Characteristics: The plants are effective in removing sedimentable solids and non-emulsified hydrocarbons with a specific weight up to 0.85 g/cm³. The systems utilize a flow splitting chamber to manage excess water by diverting it to storage tanks when inflow exceeds design specifications.
Maintenance Procedures: Regular inspections are recommended every 1-2 months to check sediment levels and clean filters. Every 6-12 months, a licensed waste disposal company should be contacted to empty and clean the system components.
Balancing Tanks: These tanks regulate the flow of rainwater to prevent overloading of sewer systems. They temporarily store excess water during heavy rainfall, releasing it gradually to comply with discharge limits set by local authorities.
Installation and Use: Proper installation includes ensuring adequate pipe slopes and connecting biogas vent pipes. Maintenance operations must adhere to safety regulations for closed wastewater treatment areas.
Key Data from Tables: The document includes detailed tables specifying flow rates, tank capacities, and dimensions for various models of treatment plants and balancing tanks, highlighting their suitability for different site conditions.
Overview: The document provides technical details on balancing tanks and treatment plants for car washes, focusing on the regulation of rainwater flow and the treatment of effluents from car washes.
Balancing Tanks: These are temporary storage units designed to regulate rainwater flow into final receptors like public sewers or watercourses. They help prevent overflow during heavy rainfall by storing excess water and releasing it gradually. The tanks are equipped with submersible pumps and manual valves to control discharge rates. They are essential in areas with high soil impermeability that can overload stormwater systems.
Specifications: The document lists various models of balancing tanks, detailing their capacities, dimensions, and maximum inlet pipe diameters. It also includes information on delivery pump kits, which come with electric pumps, control panels, and necessary fittings.
Treatment Plants for Car Washes: These systems address the treatment of runoff from car washes, which may contain pollutants like suspended solids, oils, and surfactants. The treatment process involves multiple phases: grit separation, oil separation using coalescing filters, and biological treatment with aerated trickle filters. The systems are designed to meet specific effluent concentration standards.
Plant Configurations: The document outlines different configurations for treatment plants based on the number of cars serviced per day. Each configuration includes components like grit separators, oil separators, and various types of trickle filters. The treatment efficiency is specified for each setup, ensuring compliance with environmental standards.
External Treatment Systems: These systems are compact and efficient, requiring minimal operator intervention. They use quartzite and activated charcoal filtration to treat effluents without altering the salt content, making them suitable for water reuse.
Lift Stations: Sewage lift stations are used to elevate effluent to higher levels when necessary, such as when discharge levels are below sewerage systems. They include submersible pumps, check valves, and command floats for efficient operation.
Overview
The document provides detailed specifications and configurations for ROTOTEC lift stations used in wastewater management. These systems are designed to pump pre-treated and untreated wastewater, rainwater, and other fluids to higher elevations when gravity flow is not feasible.
System Components
The lift stations consist of linear polyethylene (LLDPE) storage tanks equipped with submersible electric pumps. Depending on the application, single or dual pump models are available. The pumps are controlled via electric panels, with options for manual or automatic operation using float switches.
Specifications
  • Small Volume Lift Stations: Capacities range from 120 to 305 liters, featuring vortex or grinder impellers with varying power (0.3 to 1.18 kW) and flow rates (10-650 l/min).
  • Large Volume Lift Stations: Capacities range from 903 to 3000 liters, also using vortex or grinder impellers, with power ratings up to 2.2 kW and flow rates up to 900 l/min.
  • Teknosol Lift Stations: These stations offer rapid connection-release-extraction systems, with capacities from 400 to 3000 liters, and similar pump configurations as other models.
Pump Types
  • Multi-Channel Impeller Pumps: Suitable for clear and turbid water without solid matter.
  • Vortex Impeller Pumps: Ideal for low head sewage pumping, including solid or stringy matter.
  • Grinder Impeller Pumps: Designed for sewage with solid matter, capable of reducing solids and handling high pressure for significant elevation differences.
Applications
These lift stations are applicable in various settings, including residential, commercial, and industrial environments, where wastewater needs to be elevated to a higher level for further processing or disposal.
Recommendations
For specific pump characteristics or configurations not covered in the standard models, it is advised to contact the ROTOTEC technical office for customized solutions.
Technical Specifications:
The document provides detailed specifications for various sewage pumps and lift stations, including models such as SM650L, SM590, NRG09, and SM1100/65. Key parameters include power (KW), current (A), dimensions (mm), weight (Kg), flow rate (lt/min), and head (mt).
Functionality:
Sewage lift stations are designed to elevate effluent to higher levels for further treatment or discharge. They are essential when the discharge level is below the treatment plant or sewerage pipes. The stations consist of a polyethylene tank with a submerged electric pump, connected via a chain for easy removal. Dual pump models are available for high or variable flow rates.
Electric Panels:
Electric panels for single and dual pump lift stations are described, with options for manual or automatic operation via float switches. Panels include visual and audible alarms for fault signaling and can be powered by single-phase or three-phase electricity.
Use and Maintenance:
Maintenance should be performed by trained technicians with the pump disconnected from power. Regular inspections every 6 to 12 months are recommended to check sediment levels, seals, and the pumping system. Proper pump selection during design is crucial for efficient operation.
Warnings and Safety:
Important safety warnings include ensuring proper venting, avoiding dry starts, and maintaining vertical pump operation. Risks of electric shock are highlighted, with instructions to disconnect power before maintenance and ensure proper grounding.
Chambers and Additional Components:
The document details various chambers used in sewage systems, such as sampling, dosing siphon, non-return valve, siphon, dosing, soakaway, chlorinator, distribution, litre counter, and oil absorption chambers. Each chamber has specific functions, dimensions, and installation guidelines.
Installation Guidelines:
Guidelines for underground installation emphasize compliance with safety regulations, checking materials upon delivery, and ensuring all documentation is present. Handling instructions include using lifting eyes and avoiding impacts.
Conclusion:
The document provides comprehensive technical details and operational guidelines for sewage lift stations and associated components, emphasizing safety, maintenance, and proper installation practices.
Specifications and Prohibitions:
1. Tanks are not suitable for storing industrial waste or incompatible chemicals with polyethylene. They should not be used for diesel fuel storage.
2. Use appropriate transport and lifting equipment, ensuring tanks are empty before lifting. Avoid harsh movements during transport.
3. Use cables or straps in perfect condition, ensuring a lifting angle of no less than 45°.
Handling Instructions:
1. Use symmetrical placement of lifting cables.
2. Avoid standing under raised loads.
Underground Installation:
1. Excavate a hole with a flat bottom, leaving space around the tank. Use washed gravel for a uniform base.
2. Fill the tank with water while backfilling with gravel, ensuring the tank is filled to 3/4 capacity before final backfill with topsoil.
3. For installations in severe conditions, refer to exceptional installation guidelines.
Exceptional Installations:
1. In groundwater zones, obtain a geotechnical report and use reinforced concrete slabs.
2. In clayey/limey soil, ensure proper drainage and use washed gravel.
3. Near slopes, use reinforced concrete retaining walls.
Trafficability:
1. For light traffic, construct a self-supporting reinforced concrete slab.
2. For heavy traffic, use a reinforced concrete containment structure.
Guarantee:
1. Rototec guarantees tanks for 25 years against corrosion and defects, provided installation and maintenance guidelines are followed.
2. The guarantee excludes installation costs, damage from non-use, and transport costs.
Accessories:
1. Threaded extensions and covers are available for underground installations.
2. Gaskets and threaded rings are used for creating custom inspection holes and ensuring seals.
Technical Specifications:
1. Compressor Blower: Various models (HP40, HP60, HP80, HP150, HP200) with specifications including voltage (230V), frequency (50Hz), power (38W to 186W), flow rate (40 to 200 l/min), noise level (<37 to <50 dB), weight (5.7 to 12 kg), and dimensions.
2. Connecting Pipe in PE: Stub pipes made of HDPE for connecting storage tanks to various systems. Available in diameters from 40mm to 250mm.
3. Accessories: Electric panels (QST, QST3F) for controlling diaphragm blowers, socket timers, and diffuser plates and discs for air distribution in sludge plants.
4. Diffuser Kit: Includes diffuser plates and discs for aeration in tanks.
5. Chlorine Tablet: Trichloroisocyanuric acid tablets for long-lasting disinfection.
6. Filter Media: For percolating filters, made of black isotactic polypropylene.
7. Bio-Activators: Single-dose sachets and concentrated forms for speeding up biological processes in treatment plants.
8. Safety Grill and Electric Float: Safety devices and float level switches for water pumps.
General Conditions of Sale:
1. Orders and Payment: Orders are confirmed upon receipt of signed order confirmation. Payment terms include interest on late payments and conditions for ownership transfer.
2. Claims and Shipping: Claims must be made at unloading. Shipping terms include risk transfer to the customer and conditions for free delivery.
3. Guarantee: Products are guaranteed to meet specifications, but Rototec is not liable for incorrect installation or use.
4. Force Majeure: Rototec is not liable for delays or damages due to force majeure events.
5. Jurisdiction: Disputes are subject to the jurisdiction of the Urbino Law Courts.
Other Products:
1. Sewage Division: Includes secondary treatments and stormwater runoff systems.
2. Water Division: Offers above-ground and underground tanks, rainwater harvesting systems.
3. Portable Toilets: Includes chemical toilets, shower cabins, and accessories.
4. Construction Site Equipment: Includes debris removal systems, perimeter barriers, and portable tanks.
Note: Installation instructions for underground tanks must be followed precisely. Rototec reserves the right to modify products without prior notice.
See more

Catalog excerpts

SEWAGE TREATMENT CATALOGUE AND PRICE LIST-2

2021 SEWAGE DIVISION CATALOGUE

 Open the catalog to page 2
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-6

Rototec S.p.A. is a dynamic company in continuous expansion present throughout Italy and abroad. The company was founded in 2000 as part of the System Group, a leader in the production of complete pipeline systems (pipes, fittings, specials,...). It was soon specializing in the production of corrugated and smooth tanks in linear polyethylene manufactured using rotational moulding technology. Over the years, Rototec S.p.A. has always felt the need to distinguish itself on the Italian and international markets, investing its resources in research and in updating its own production to meet European...

 Open the catalog to page 6
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-8

ROTOTEC SERVICES > Organisation of training meetings, technical seminars and in-house training > A large network of agents and retailers throughout Italy and abroad > Design work during the plant sizing phase > Digital support during design work using tools such as: . plant configuration software . bim libraries . website updated in real time > Prompt delivery > On-site technical support > After-sales service

 Open the catalog to page 8
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-9

SYSTEM GROUP in the worlc

 Open the catalog to page 9
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-10

ROTOTEC & SYSTEMGROUP System Group was created in a small town inland of Mi Plastic Romania). The group further reinforced its Pesaro (Lunano) as a result of an idea by entrepreneur Alvaro Boscarini who, in 1979, had founded Centraltubi for the production of polyethylene pipes. The group was formed at the start of the 1990's when Centraltubi was joined by Futura, a company operating in the pipe fittings, accessories and specials market. These were to be the first steps on the road to success which, in the following years, saw the birth of five other important businesses: Sa.Mi Plastic (smooth...

 Open the catalog to page 10
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-12

p. 12 SEWAGE DIVISION p. 190 UNDERGROUND INSTALLATION p. 198 ACCESSORIES p. 208 OTHER PRODUCTS

 Open the catalog to page 12
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-14

EXAMPLE OF PLANT SOLUTIONS CALCULATION OF POPULATION EQUIVALENT CERTIFICATIONS GREASE SEPARATORS IMHOFF BIOLOGICAL TANKS BIOLOGICAL SEPTIC TANKS SEWAGE TREATMENT PLANTS - DEPURO ACTIVATED SLUDGE PLANTS TRICKLE FILTERS HIGH EFFICIENCY SECONDARY TREATMENTS DEPURBLOK GRIT SEPARATORS COALESCING FILTER TYPE OIL SEPARATORS COALESCING OIL SEPARATOR WITH INTEGRATED BYPASS CONTINUOUS STORMWATER RUNOFF TREATMENT PLANTS BALANCING TANKS TREATMENT PLANTS FOR CAR WASHES LIFT STATIONS CHAMBERS

 Open the catalog to page 14
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-15

SEWAGE DIVISION PLANT SOLUTIONS Grease separator (where provided) Imhoff or septic biological tank OUTLET Grease separator (where provided) Imhoff or septic biological tank Anaerobic trickle filter Optional flushing chamber

 Open the catalog to page 15
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-16

Grease separator (where provided) OUTLET Imhoff or septic biological tank Low-load activated sludge plant Imhoff or septic biological tank Secondary treatment with sludge recirculation

 Open the catalog to page 16
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-17

SEWAGE DIVISION CALCULATION OF POPULATION EQUIVALENT The concept of Population Equivalent (PE) is useful for expressing the load on a treatment plant from a particular user in standard terms comparable with domestic users. The equivalence can refer to the hydraulic load, to the load in suspended solids or, more commonly, to the organic load expressed as BOD5. Population Equivalent is a conventional concept based on the mean contribution from a typical user equal to 60 g/BOD5 per inhabitant (Law Decree 152/2006). It is also particularly useful in that it allows a simple comparison to be made between...

 Open the catalog to page 17
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-18

SEWAGE DIVISION CERTIFICATIONS

 Open the catalog to page 18
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-21

SEWAGE DIVISION GREASE SEPARATORS inlet zone in which the turbulence of the inlet flow is dampened and in which the substances with a specific weight lower than water (oils, foams, etc...) accumulate. STILLING AREA zone into which the separated and treated effluent flows. 3 area in which temporary accumulation of the solids (food waste, etc...) takes place. INSTALLATION DIAGRAM Grease separator Imhoff or septic biological tank

 Open the catalog to page 21
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-22

SEWAGE DIVISION GREASE SEPARATORS SPECIFICATIONS TECHNICAL CHARACTERISTICS The grease separator is a physical pre-treatment process that removes oils, foams, greases and all substances of specific weight less than that of the effluent. The grease separator is nothing more than a stilling tank in which the substances of specific weight less than water are separated by floatation (surface). Sedimentation also takes place, with a part of the suspended solids depositing at the bottom of the tank. Primary treatment of grey water from kitchens, washbasins, bidets, showers, baths, washing machines and...

 Open the catalog to page 22
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-23

SEWAGE DIVISION GREASE SEPARATORS GREASE SEPARATORS MODEL SMOOTH SEPARATION BAFFLES GREASE SEPARATORS MODULAR

 Open the catalog to page 23
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-24

SEWAGE DIVISION GREASE SEPARATORS Sizing: PE. = population equivalent: 0 = diameter; H = height; HI = inlet pipe height; HO = outlet pipe height; 0E/U = inlet/outlet pipe diameter; NS = limit flow rate (l/s). ROTOTEC

 Open the catalog to page 24
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-25

ABOVE-GROUND GREASE SEPARATORS TECHNICAL CHARACTERISTICS the grease separator is a physical pre-treatment process that removes oils, foams, greases and all substances of specific weight less than that of the effluent. The grease separator is nothing more than a stilling tank in which the substances of specific weight less than water are separated by floatation (upward flow to the surface). Sedimentation also takes place, with a part of the suspended solids depositing at the bottom of the tank. Its reduced width allows it to be carried through doorways. In this way, it can be installed in a suitable...

 Open the catalog to page 25
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-26

SEWAGE DIVISION GREASE SEPARATORS UNDER-SINK GREASE SEPARATORS Item TECHNICAL CHARACTERISTICS The grease separator is a physical pre-treatment process that separates oils, foams, grease, heavy sediment and all substances of specific weight less than that of the effluent. The under-sink grease separator has been designed to be fitted directly under the kitchen sink of small restaurants, small beach cantinas, little bars. USE Primary treatment of grey water from kitchen sinks, washbasins, etc...

 Open the catalog to page 26
SEWAGE TREATMENT CATALOGUE AND PRICE LIST-27

SEWAGE DIVISION GREASE SEPARATORS TECHNICAL SECTION - GREASE SEPARATORS TECHNICAL CHARACTERISTICS The grease separator is a physical pre-treatment process that removes oils, foams, greases and all substances of specific weight less than that of the effluent. Greases and oils produced during normal domestic activities derive from the consumption of butter, margarine, lard and vegetable oils. They also originate from waste meat and vegetables and from some cosmetic products. Greases are insoluble in water and have a low density. In the presence of surface-active agents (detergents), they create...

 Open the catalog to page 27

All ROTOTEC SPA catalogs and technical brochures

  1. WATER DIVISION

    112  Pages

  2. KITank

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.