ANGLE SEAT VALVE SINGLE ACTING FEATURES • • • • • • • • • • Easy conversion from Single Acting to Double Acting Modular Design, multiple Operator option possible on the same valve Body Lubricated pilot Air not required Designed to work up to 10-6 Torr Vacuum Fast acting up to 500 cycles/ hour Wetted Parts : CF8, SS 304. Optionally same can be provided with CF3M & SS 316L SS 303 inserts for Operator ports Operation Life > 3 Million cycles Pressurisation of spring chamber in case of single acting operator using appropriate 5/2 valve Quick operation of valve possible using appropriate 5/2...

Open the catalog to page 2
ANGLE SEAT VALVE  E-1.0 - 3

ANGLE SEAT VALVE DOUBLE ACTING UNIVERSAL NC / NO / Bi Directional Operation Modular Design, multiple Operator option possible on the same valve Body Lubricated pilot Air not required Designed to work up to 10-6 Torr Vacuum Fast acting up to 1,000 cycles/ hour Wetted parts : CF8, SS 304. Optionally same can be provided with CF3M & SS 316L Operation Life > 3 Million cycles SS 303 inserts for Operator ports NAMUR Port • Aluminium hard anodized piston • Stationery seal, Sealing on Aluminium Piston • Low friction • Longer life • Sealing on Aluminium Piston • Transparent Dome for visual valve...

Open the catalog to page 3
ANGLE SEAT VALVE  E-1.0 - 4

ANGLE SEAT VALVE WITH INTELLIGENT POSITIONER FEATURES X1 • Can be adapted to Single/ Double Acting Angle Seat Valve • Auto tuning • User friendly settings • INPUT Power 24V DC Signal 0/4 - 20mA/ 0 - 5/10V From Sensor 4 - 20mA (applicable for VL141, VL141D) • OUTPUT Position Feedback 0/4 - 20mA/ 0 - 5/10V • Suitable for Pilot Pressure 3-7 bar • Optional one Analog Input for Process Control • Emergency Shut Off signal • Valve full Open/ Close status Signal provided • Ambient Temperature 0 - 55 °C • Weather Proof IP65 ORDERING CODE • Select VL14, V14D, VL141, VL141D from accessories table...

Open the catalog to page 4
ANGLE SEAT VALVE  E-1.0 - 5

ANGLE SEAT VALVE WITH ELECTRONIC POSITIONER FEATURES • Can be adapted to Single Acting Normally Close Angle Seat Valve • Prominent Visual LED indicator in 10 steps for indication of valve opening from 0 to 100% • User Friendly Setting • LED indication for Manual/ Auto mode • INPUT Power 24V DC Signal 4 - 20mA • OUTPUT Position Feedback 4 - 20mA • Suitable for Pilot Pressure 3-7 bar • Ambient Temperature 0 - 55 °C • Weather Proof IP65 ORDERING CODE • Select VL15 from accessories table (Refer pages 17, 21, 25) VL15 CONNECTION VL15 X2 Position Feedback Output 0/4 - 20mA X3 Input Signal 4 -...

Open the catalog to page 5
ANGLE SEAT VALVE  E-1.0 - 6

ANGLE SEAT VALVE WITH VALVE POSITION SENSOR FEATURES • Suitable only for Normally Closed Single Acting Angle Seat Valve • Can sense full open position of the valve • Potential free feedback from SPDT, Micro Switch rating 3A AC, 0.5A DC Refer to page 9 for more details ORDERING CODE • Select PSSA50 or PSSA63 or PSSA 90 or PSSA110 from accessories table (Refer pages 17, 21, 25) Specifications are subject to change without n

Open the catalog to page 6
ANGLE SEAT VALVE  E-1.0 - 7

ANGLE SEAT VALVE WITH VALVE POSITION SENSOR FEATURES • Suitable for Double/ Single Acting NC, NO Angle Seat Valve • Metallic Aluminium Cast Epoxy Powder coated enclosure having IP67 protection, • Dual cable entry for possibility to terminate solenoid in the junction box and having one cable in to limit switch box • Up to two sensors each for Open and Close position of the valve • For ease of cabling, Limit Switch Box Can be rotated 360o • Sensing element : Micro Switch, WP/ Ex ia, Proximity Switch Refer to page 10 for more details ORDERING CODE • Select LS21 or LS41 or LS22 or LS42 or LS23...

Open the catalog to page 7
ANGLE SEAT VALVE  E-1.0 - 9

ACCESSORIES GROTEX 7tt& frtZvu, STROKE LIMITERFEATURES Ideal for application demanding preset flow adjustment Can be retrofitted at site Adjust stroke for Valve opening from 0% to 100% Can be adapted to Single Acting Normally Closed Angle Seat Valve Stainless Steel 304 bolt Specifications are subject to change without notice

Open the catalog to page 9
ANGLE SEAT VALVE  E-1.0 - 10

POSITION SENSOR BOX (Should be ordered along with Valve) FEATURES Adjustable Sensing elements Suitable for Single/ Double acting Normally Close/ Open valve Enclosure Material Protection Sensing Element Cable Entry Aluminium Cast Powder Coated Weather Proof, IP67 Optionally Weather Proof IP67 with Ex ia sensing Element Micro Switch/ Proximity Sensor 2 X M25 X 1.5 Sensing Element Cable Entry SENSING ELEMENT Model Specifications are subject to change without notice

Open the catalog to page 10
ANGLE SEAT VALVE  E-1.0 - 11

ANGLE SEAT VALVEACCESSORIES SOLENOID VALVE (Can be ordered Separately) CuTR PESO SPECIFICATION (Refer pages 16, 20 & 24 for Solenoid Valve code) • Pressure : 10 bar • Voltage Current : 24V DC, 110V 50-60 Hz, 230V 50-60 Hz • Port connection: 1/4" BSP • Power : 8W/ 2W/ 1W • Body Material : Aluminium hard Anodised • Protection : Weather Proof IP67 • Seat Seal : NBR Explosion Proof Ex d, Ex ia, Ex e mb, IIC T6, IP67 VALVE TYPE VALVE TYPE VALVE TYPE VALVE TYPE

Open the catalog to page 11
ANGLE SEAT VALVE  E-1.0 - 12

SINGLE ACTING NORMALLY CLOSED F1/ F6 OPERATING PARAMETERS DN Operator 1. For PED certified valves, maximum fluid pressure is limited to minimum value specified in pressure temperature chart on page 8 or table above 2. Valve with F5 function using 5/2 solenoid valve should be replaced by valve with F1 function operated by 5/2 valve 3. Valve with F3 function should be replaced by selecting suitable valve meeting operating parameter of main fluid pressure above, below seat and pilot pressure Specifications are subject to change without notice

Open the catalog to page 12
ANGLE SEAT VALVE  E-1.0 - 13

OPERATING PARAMETERS Specifications are subject to change without notice

Open the catalog to page 13
ANGLE SEAT VALVE  E-1.0 - 14

SINGLE ACTING NORMALLY CLOSED F1/ F6 OPERATING PARAMETERS DN Operator 1. For PED certified valves, maximum fluid pressure is limited to minimum value specified in pressure temperature chart on page 8 or table above 2. Valve with F5 function using 5/2 solenoid valve should be replaced by valve with F1 function operated by 5/2 port valve 3. Valve with F3 function should be replaced by selecting suitable valve meeting operating parameter of main fluid pressure above, below seat and pilot pressure Specifications are subject to change without notice

Open the catalog to page 14

All Rotex Automation Limited catalogs and technical brochures

  1. 30308

    16 Pages

  2. 3275I

    2 Pages

  3. 30316

    14 Pages

  4. 31206

    18 Pages

  5. 30125

    3 Pages

  6. 51427

    1 Pages

  7. 51424

    2 Pages

  8. 51401

    5 Pages

  9. 51440

    16 Pages

  10. 30150

    2 Pages

  11. 3359V01

    1 Pages

  12. 24106

    2 Pages

  13. 24114

    2 Pages

  14. 24106D

    2 Pages

  15. 26106

    2 Pages

  16. 12050V01

    36 Pages

  17. 53445

    2 Pages

  18. 24110

    1 Pages

  19. 24101LC

    7 Pages

  20. P5003

    16 Pages

  21. 21131

    12 Pages

  22. 20116

    2 Pages

  23. 20172

    2 Pages

  24. 21101

    4 Pages

  25. 24101

    8 Pages

  26. 21109

    2 Pages

  27. 3322

    1 Pages

  28. 20201

    4 Pages

  29. 21101

    4 Pages

  30. 20172

    2 Pages

  31. E-7.2

    447 Pages

  32. 5/2 MONO

    2 Pages

  33. MANIFOLD

    4 Pages