Series W70 and W74
7Pages

{{requestButtons}}

Catalog excerpts

Series W70 and W74 - 1

Spool & Sleeve Valves for ANSI Sub-Bases Series W70 5/2 Valves - Single Direct Solenoid, Spring Return Dimensions mm Weight ^A_B_C kg ANSI Range of Valve Model Avg. Size Port Sizes_Number*_k^ 5/2 Valves - Double Pressure Controlled, Detented ANSI Range of Valve Model Avg. Dimensions mm Weight Size Port SizesNumber*kv_ABC_kg 5/3 Valves - Double Direct Solenoid Valve Model Number* ANSI Range of Power Closed Open Average Dimensions mm Weight Size Port SizesCenterCenterCenterkvABCkg 1 G 1/8 - G 3/8 W7017B2905 W7017B2331 W7017B2332 0.9 226 50 58 2.0 Indicator Light: Available Ambient Temperature: 4°C to 50°C. Media Temperature: 4°C to 80°C. Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: Vacuum to 10 bar. STANDARD SPECIFICATIONS (for valves on this page): Solenoids: AC power; DC for size 1 models only. Leistungsaufnahme: Modelle G 1/4-3/8: 140 VA beim Anzug; 30 VA im Betrieb bei Wechselstrom; 20 W nominal bei Gleich-strom. Alle anderen Modelle: 380 VA beim Anzug; 58 VA im Betrieb bei Wechselstrom.

Open the catalog to page 1
Series W70 and W74 - 2

Spool & Sleeve Valves for ANSI Sub-Bases Series W70 5/2 Valves - Single Solenoid Pilot Controlled, Spring Return ANSI Range of Valve Model Avg. Dimensions mm Size Port Sizes_Number*_kv_A_B_C_^ 5/2 Valves - Double Solenoid Pilot Controlled, Detented ANSI Range of Valve Model Avg. Dimensions mm Weight Size Port SizesNumber*_k_ABC_kg 5/3 Valves - Double Solenoid Pilot Controlled Closed Center Open Center Open Average Dimensions mm Weight Size Port SizesCenterCenterCenterkvABCkg 1 G 1/4 - G 3/8 W7077B2906 W7077B2331 W7077B2332 0.9 194 50 59 1.8 Ambient...

Open the catalog to page 2
Series W70 and W74 - 3

Spool & Sleeve Valves for ANSI Sub-Bases Series W70 5/2 Valves - Single Pressure Controlled, Spring Return ANSI Range of Valve Model Avg. Dimensions mm Weight Size Port SizesNumber*kv_ABC_kg *Sub-base not included. See pages 28-30 for sub-bases, manifolds and accessories. 5/2 Valves - Double Pressure Controlled, Detented ANSI Range of Valve Model Avg. Dimensions mm Weight Size Port SizesNumber*kv_ABC_kg 5/3 Valves - Double Pressure Controlled Valve Model Number* ANSI Range of Power Closed Open Average Dimensions mm Weight Size Port SizesCenterCenterCenterkvABCkg 1 G...

Open the catalog to page 3
Series W70 and W74 - 4

Poppet Valves for ANSI Sub-Bases Series W74 5/2 Valves - Single Solenoid Pilot Controlled, Air Return Range of Avg. Valve Model Numbers* Weight Size Port Sizes kv Std. Temp. High Temp._kg 5/2 Valves - Double Solenoid Pilot Controlled, Detented Range of Avg. Valve Model Numbers* Weight Size Port Sizes k,, Std. Temp. High Temp._kg STANDARD SPECIFICATIONS: (for valves on this page): Solenoids: AC or DC power. Power Consumption: Each solenoid. CV = 0.9 models: 10 VA inrush, 9 VA holding on 50 or 60 Hz; 5 watts on DC. All other sizes: 87 VA inrush, 30 VA holding...

Open the catalog to page 4
Series W70 and W74 - 5

Poppet Valves for ANSI Sub-Bases Series W74 5/2 Valves - Single Pressure Controlled, Air Return Range of Avg. Valve Model Numbers* Weight Size Port Sizeskv Std. Temp. High Temp. kg 5/2 Valves - Double Pressure Controlled, Detented Range of Avg. Valve Model Numbers* Weight Size Port Sizeskv Std. Temp. High Temp. kg STANDARD SPECIFICATIONS: (for valves on this page): Ambient/Media Temperature: 4° to 80°C; media temperature extended to 105°C for High Temperature models. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: 2 to 10 bar. Pilot Pressure: Must be equal to or...

Open the catalog to page 5
Series W70 and W74 - 6

The sub-base numbers shown in the chart below specify pressure ports withthreads, conforming to ISO 228/1. Electrical openings have G 1/2 threads. For other types, consult ROSS. ANSI-Type SUB-BASES VALVE MODEL NUMBERS STANDARD SPECIFICATIONS kV Rating: 0.9 Solenoids: AC or DC power. Power Consumption: 8 VA inrush, 6 VA holding on 50 or 60 Hz; 6 watts on DC. Ambient Temperature: -15° to 50°C. Media Temperature: -15° to 80°C. For temperatures below 4°C air must be free of water vapor to prevent formation of ice. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: Vacuum to 10 bar.

Open the catalog to page 6
Series W70 and W74 - 7

The numbers of the manifold stations shown in the chart below specify pressure ports with ISO 228/1 threads, and electrical openings with G 1-1/4 threads. For other thread types,consult ROSS. All necessary hardware and seals for manifold assembly are included with each manifold station. Indicator Lights: As shown in the chart below, the smaller sizes of manifolds are available with indicator lights. These lights are located in the end plate covering the electrical cavity. Manifold Note: The port positions of the solenoid controlled and the pressure controlled manifolds are not the same....

Open the catalog to page 7

All ROSS EUROPA catalogs and technical brochures

  1. E505E

    16 Pages

  2. E-RE-08

    68 Pages

  3. E620D

    20 Pages

  4. E481

    5 Pages

  5. D385B

    30 Pages

  6. E425F

    29 Pages

  7. Pinch Valves

    9 Pages

  8. E104

    110 Pages

  9. E372A

    20 Pages

  10. E485

    20 Pages

  11. Series W65

    5 Pages

  12. Series D21

    2 Pages

  13. Series D27

    3 Pages

  14. E200

    28 Pages

Archived catalogs

  1. Compact Valves

    24 Pages