5/2 Valves - Single Solenoid Pilot Spring Return * Base and electrical connector not included. OPEN CENTER STANDARD SPECIFICATIONS: For valves on this page. Solenoids: AC or DC power. Power Consumption: 10,9 VA inrush, 8.5 VA holding on 50 or 60 HZ; 6 watts on d.c. Ambient Temperature: 4o to 50o C. Media Temperature: 4o to 80o C. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: Vacuum to 10 bar (16 bar on request). Pilot Pressure: Size 1: At least 2 bar. Size 2, 3 and 4: At least 1 bar.
Open the catalog to page 15/2 Valves - Single Pressure Control Spring Return 5/2 Valves - Double Pressure Momentary Control 5/3 Valves - Double Pressure Control STANDARD SPECIFICATIONS: For valves on this page. Ambient Temperature: 4o to 80o C. Media Temperature: 4o to 80o C. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: Vacuum to 10 bar (16 bar on request). Pilot Pressure: Size 1: At least 2 bar. Size 2, 3 and 4: At least 1 bar. ROSS EUROPA®
Open the catalog to page 2* Base and electrical connector not included. 5/2 Valves - Double Solenoid Pilot Momentary Control ISOSize ^ * Base and electrical connector not included. 5/3 Valves - Double Solenoid Pilot ISOSize * Base and electrical connector not included. CLOSED CENTER OPEN CENTER STANDARD SPECIFICATIONS: For valves on this page. Solenoids: AC or DC power. Power Consumption: 10,9 VA inrush, 8,5 VA holding on 50 or 60 Hz; 6 watts on d.c. Ambient Temperature: 4o to 50o C. Media Temperature: 4o to 80o C. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: Vacuum to 16 bar. Pilot Pressure: Size...
Open the catalog to page 35/2 Valves - Single Pressure Control Air Return 5/2 Valves - Double Pressure Control Momentary Control 5/3 Valves - Double Pressure Control STANDARD SPECIFICATIONS: For valves on this page. Ambient Temperature: 4o to 80o C. Media Temperature: 4o to 80o C. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: Vacuum to 16 bar. Pilot Pressure: Size 1: At least 2 bar. Size 2 and 3: At least 1 bar. ROSS EUROPA®
Open the catalog to page 4* Base and electrical connector not included. 5/2 Valves - Double Solenoid Pilot Momentary Control ISO Size * Base and electrical connector not included. STANDARD SPECIFICATIONS: For valves on this page. Solenoids: AC or DC power. Power Consumption: 10,9 VA inrush, 8,5 VA holding on 50 or 60 Hz; 6 watts on d.c. Ambient Temperature: 4o to 50o C; extended to 80o C for High Temperature models. Media Temperature: 4o to 80o C; extended to 105o C for High Temperature models. Flow Media: Filtered air. 5 micron recommended. Inlet Pressure: 2-10 bar. Pilot Pressure: Must be equal to or greater than inlet...
Open the catalog to page 55/2 Valves - Double Pressure Control Momentary ISO Size *External pilot supply port (14) and remote pilot ports (12 and 14): G 1/8. ROSS EUROPA®
Open the catalog to page 6VDMA 24345, Forms C and D Hardware and seals for joining manifold stations are included with each station. An end station kit, which includes two end plates with threaded inlet and exhaust ports, must be ordered for each manifold installation. Pilot ports have G 1/8 threads. Blocking discs are available for each of the four ISO sizes. Order by the numbers in the chart below.