Catalog excerpts
Series 250 Single or Double Solenoid Valve Model Numbers (Base not included) SAE Type of Wiring Avg. Dimensions inches (mm) Weight SOL B “ ''It' HTTTlt ItN-EBP EA Closed Center STANDARD SPECIFICATIONS (for valves on this page): Solenoids: AC or DC power. Rated for continuous duty. Standard Voltages: Series 125, 250 models: 100-110 volts, 50 Hz; 100-120 volts, 60 Hz; 24 volts DC; 110 volts DC. For other voltages, consult ROSS. Series 500 models: 100-110 volts, 50 Hz; 100-120 volts, 60 Hz; 24 volts DC; 110 volts DC. For other voltages, consult ROSS. Power Consumption: Each solenoid: Series 125, 250 models: 8 VA inrush; 6 VA holding on 50/60 Hz; 8 watts on DC. Power Consumption: Each solenoid: Series 500 models: 87 VA inrush; 30 VA holding on 50/60 Hz; 14 watts on DC. Indicator Light: One for each solenoid. Ambient Temperature: 40° to 120°F (4° to 50°C). Media Temperature: 40° to 175°F (4° to 80°C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: Vacuum to 150 psig (10 bar). Pilot Pressure: At least 15 psig (1 bar). Options: Pressure Controlled Valves-Interposed Pressure Regulators. IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.
Open the catalog to page 1Series 250 Single or Double Solenoid EBpEA Single Solenoid Valve Model Numbers (Base not included) SAE Type of Wiring Avg. Dimensions inches (mm) Weight Series Ford Chrysler Hardwire CV A Single Solenoid Pilot Valves 125 8476C3331 8476C3341 8476C3351 1.8 5.5 (140) 1.8 (45) 5.1 (129) 2.8 (1.3) Double Solenoid Pilot Valves 125 8476C3332 8476C3342 8476C3352 1.8 5.5 (140) 1.8 (45) 5.1 (129) 3.3 (1.5) * Sub-bases and manifolds on pages 33-34. IMPORTANT NOTE: The CV values given in the table above should not be used in...
Open the catalog to page 2Sub-Bases for SAE Valves Series 80 & 84 Side-Ported Dimensions: inches (mm) Series 125 Port EA (exhaust) *NPT threads. For SAE threads, consult ROSS. Series 250 Port EA (exhaust) *NPT threads. For SAE threads, consult ROSS. 1/8 external pilot supply port X *NPT threads. For SAE threads, consult ROSS. Port B (outlet) Sub-Base Number 1/8 external pilot supply port X
Open the catalog to page 3Series 125 Manifold Stations Station Port Sizes* *NPT threads. For SAE threads, consult ROSS. Blanking Plate: For manifold stations not occupied by a valve, blanking plates are available. These plates block the unused air passages. Order by part number 820K77. Series 250 Manifold Stations Station Port Sizes* *NPT threads. For SAE threads, consult ROSS. Blanking Plate: For manifold stations not occupied by a valve, blanking plates are available. These plates block the unused air passages. Order by part number 821K77. Series 500 Manifold Stations Station Port Sizes* *NPT threads. For...
Open the catalog to page 4All ROSS EUROPA catalogs and technical brochures
-
E505E
16 Pages
-
E-RE-08
68 Pages
-
E620D
20 Pages
-
E481
5 Pages
-
D385B
30 Pages
-
E425F
29 Pages
-
ROSS/FLEX® - Profile
1 Pages
-
Pinch Valves
9 Pages
-
E104
110 Pages
-
E372A
20 Pages
-
E485
20 Pages
-
Series W70 and W74
7 Pages
-
Series W65
5 Pages
-
Series W60, W63 and W64
7 Pages
-
Series D21
2 Pages
-
Series D27
3 Pages
-
Pneumatic Machine Safeguarding
32 Pages
-
DM2 - Double Valves
20 Pages
-
E200
28 Pages
Archived catalogs
-
Compact Valves
24 Pages
-
ISO Valves for Base Mounting
28 Pages
-
ISO/VDMA-Standard, Size 0
6 Pages
-
ROSS-Safety-related valves
12 Pages