1. Catalogs
  2. ROSS EUROPA
  3. Series 80 and 84

Series 80 and 84

Series 80 and 84

Series 80 and 84

Product catalog summary
Standard Specifications:
The document outlines specifications for solenoid valves, which can operate on AC or DC power and are rated for continuous duty. Standard voltages for Series 125 and 250 models include 100-110 volts at 50 Hz, 100-120 volts at 60 Hz, 24 volts DC, and 110 volts DC. Series 500 models share the same voltage specifications. Power consumption varies by series, with Series 125 and 250 models consuming 8 VA inrush and 6 VA holding on AC, and 8 watts on DC. Series 500 models consume 87 VA inrush and 30 VA holding on AC, and 14 watts on DC. Each solenoid is equipped with an indicator light.

Environmental Conditions:
The ambient temperature range for operation is 40° to 120°F (4° to 50°C), and the media temperature range is 40° to 175°F (4° to 80°C). The flow media should be filtered air, with a 5-micron filter recommended. Inlet pressure ranges from vacuum to 150 psig (10 bar), and pilot pressure must be at least 15 psig (1 bar).

Valve Configurations:
The document details various spool valve configurations, including 5/2 and 5/3 spool valves, with options for single and double solenoids. It also provides model numbers for different configurations and wiring types, along with dimensions and weights.

Sub-Bases and Manifolds:
Sub-bases and manifolds are available for Series 80 and 84 valves, with specific port sizes and configurations. The document lists part numbers for sub-bases and manifolds, including options for NPT and SAE threads. Blanking plates are available for unused manifold stations.

Important Notes:
The document emphasizes the importance of consulting ROSS for voltages not listed and notes that CV values provided are for use with ROSS performance charts only. It also highlights the availability of manual override kits and interposed devices, with references to additional bulletins for more information.
See more

Catalog excerpts

Series 80 and 84-1

Series 250 Single or Double Solenoid Valve Model Numbers (Base not included) SAE Type of Wiring Avg. Dimensions inches (mm) Weight SOL B “ ''It' HTTTlt ItN-EBP EA Closed Center STANDARD SPECIFICATIONS (for valves on this page): Solenoids: AC or DC power. Rated for continuous duty. Standard Voltages: Series 125, 250 models: 100-110 volts, 50 Hz; 100-120 volts, 60 Hz; 24 volts DC; 110 volts DC. For other voltages, consult ROSS. Series 500 models: 100-110 volts, 50 Hz; 100-120 volts, 60 Hz; 24 volts DC; 110 volts DC. For other voltages, consult ROSS. Power Consumption: Each solenoid: Series 125, 250 models: 8 VA inrush; 6 VA holding on 50/60 Hz; 8 watts on DC. Power Consumption: Each solenoid: Series 500 models: 87 VA inrush; 30 VA holding on 50/60 Hz; 14 watts on DC. Indicator Light: One for each solenoid. Ambient Temperature: 40° to 120°F (4° to 50°C). Media Temperature: 40° to 175°F (4° to 80°C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: Vacuum to 150 psig (10 bar). Pilot Pressure: At least 15 psig (1 bar). Options: Pressure Controlled Valves-Interposed Pressure Regulators. IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.

 Open the catalog to page 1
Series 80 and 84-2

Series 250 Single or Double Solenoid EBpEA Single Solenoid Valve Model Numbers (Base not included) SAE Type of Wiring Avg. Dimensions inches (mm) Weight Series Ford Chrysler Hardwire CV A Single Solenoid Pilot Valves 125 8476C3331 8476C3341 8476C3351 1.8 5.5 (140) 1.8 (45) 5.1 (129) 2.8 (1.3) Double Solenoid Pilot Valves 125 8476C3332 8476C3342 8476C3352 1.8 5.5 (140) 1.8 (45) 5.1 (129) 3.3 (1.5) * Sub-bases and manifolds on pages 33-34. IMPORTANT NOTE: The CV values given in the table above should not be used in comparing...

 Open the catalog to page 2
Series 80 and 84-3

Sub-Bases for SAE Valves Series 80 & 84 Side-Ported Dimensions: inches (mm) Series 125 Port EA (exhaust) *NPT threads. For SAE threads, consult ROSS. Series 250 Port EA (exhaust) *NPT threads. For SAE threads, consult ROSS. 1/8 external pilot supply port X *NPT threads. For SAE threads, consult ROSS. Port B (outlet) Sub-Base Number 1/8 external pilot supply port X

 Open the catalog to page 3
Series 80 and 84-4

Series 125 Manifold Stations Station Port Sizes* *NPT threads. For SAE threads, consult ROSS. Blanking Plate: For manifold stations not occupied by a valve, blanking plates are available. These plates block the unused air passages. Order by part number 820K77. Series 250 Manifold Stations Station Port Sizes* *NPT threads. For SAE threads, consult ROSS. Blanking Plate: For manifold stations not occupied by a valve, blanking plates are available. These plates block the unused air passages. Order by part number 821K77. Series 500 Manifold Stations Station Port Sizes* *NPT threads. For SAE...

 Open the catalog to page 4

All ROSS EUROPA catalogs and technical brochures

  1. E505E

    16  Pages

  2. E-RE-08

    68  Pages

  3. E620D

    20  Pages

  4. E481

    5  Pages

  5. D385B

    30  Pages

  6. E425F

    29  Pages

  7. Pinch Valves

    9  Pages

  8. E104

    110  Pages

  9. E372A

    20  Pages

  10. E485

    20  Pages

  11. Series W65

    5  Pages

  12. Series D21

    2  Pages

  13. Series D27

    3  Pages

  14. E200

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.