1. Catalogs
  2. ROSS Controls
  3. Valves and Serial Bus Communication with Turck Modular I/O System

Valves and Serial Bus Communication with Turck Modular I/O System

Valves and Serial Bus Communication with Turck Modular I/O System
1 / 48 PagesView full catalog

Valves and Serial Bus Communication with Turck Modular I/O System

Product catalog summary
Standard Definitions: The document outlines standards for valve sizes, including 15407-1 and 15407-2 for plug-in standards, and 5599-1 and 5599-2 for drop-cord standards, applicable to valve sizes from 00 (18mm) to 3.
Serial Bus Systems: It details serial bus communication offerings for ISO valves, with certifications like UL, CE, and CSA, emphasizing centralized systems and proximity of pneumatics and I/O.
ISO Size 00 & 0 Valves, Series W66: This section provides ordering codes for valve configurations, including solenoid options, pilots, voltage options, and model numbers.
Plug-in, ISO Size 00 & 0 Valves Series W66 (15407-2): Specifications for plug-in valves include dimensions, weight, flow media requirements, solenoid types, standard voltages, and operating pressures.
Spool and Sleeve Valves for ISO Sub-Bases Size 1, 2 & 3 Valves, Series W65 (5599/II): Specifications include solenoid ratings, power consumption, materials, and ease of maintenance with serial data communication systems.
Technical Information: Includes solenoid specifications, standard voltages, power consumption, operating conditions, materials, and certification approvals.
Gateways and Modules: Outlines gateways for DeviceNet, Ethernet, Profibus-DP, and CANopen, with a selection guide for the TURCK Modular Industrial I/O System BL67.
Standard Cautions and Warranty: Includes cautions on product selection and use, emphasizing user responsibility for performance and safety, and outlines warranty terms for TURCK and ROSS products.
Standard Specifications: Specifications for Spool and Sleeve Valves for ISO Sub-Bases (5599/II) Series W65 include temperature range, flow media, inlet pressure, pilot supply, and materials.
Valve Models and Dimensions: Provides information on valve models, ISO port sizes, model numbers, average CV, dimensions, and weight.
Ordering Information: Instructions for ordering manifold and sub-base kits, including mounting style, port size, and enclosure/lead length.
Accessories and Kits: Lists accessories and kits like manifold port isolation kits, blank station kits, and manifold to manifold gasket kits.
Service and Repair Kits: Details service and repair kits, including replacement pilot assembly and coil, valve bolt kits, manifold hardware kits, and regulator kits.
Technical Information: Includes temperature ratings, response times, operating pressures, and flow rating (Cv) tested per ANSI standards.
Specifications: Outlines specifications for solenoid and pilot-operated valves, detailing pressure requirements.
BL67 Solution Overview: Describes the BL67 system as a modular, rugged I/O system supporting various fieldbus protocols, suitable for IP 67 protection applications.
Power Distribution and Consumption: Details power distribution for BL67 stations, emphasizing the use of I/O assistant software for power and size restrictions.
Environmental Conditions: The BL67 system is designed for rugged environments, offering IP 67 protection, but not suitable for continuous submersion or high-pressure washdowns.
Gateways and Connectivity: Describes gateways and their specifications, including operating current, supply current, and protection levels.
Diagnostics and Programmability: Diagnostic information is available through the DeviceNet I/O map, with programmable gateways using CodeSys.
Module Types and Power Requirements: Lists module types and their nominal current requirements, emphasizing power feeder modules to prevent overloading.
Conclusion: The BL67 system offers a robust solution for industrial I/O needs, with comprehensive specifications for power, environmental conditions, and connectivity.
Overview: Provides detailed specifications and configurations for the TURCK Modular Industrial I/O System BL 67, focusing on discrete input and output modules.
Specifications:
  • Electrical: Operating current and output current specifications.
  • Power Distribution: Inputs powered by VO, logic powered by VMB and VO.
  • Material: Connectors made of nickel-plated brass, housing made of PC-VO (Lexan).
  • Protection: IP 67 protection for harsh environments.
Modules:
  • Discrete Input Modules: Available in 4 and 8 input configurations with diagnostic LEDs.
  • Discrete Output Modules: Available in 4, 8, and 16 output configurations with diagnostic LEDs.
  • Deluxe Modules: Enhanced input modules with additional diagnostics.
Diagnostics:
  • Logical Diagnostics: Available through the fieldbus gateway.
  • Physical Diagnostics: LEDs indicate module bus communication status and I/O diagnostics.
Connectivity: Specifies mating cordsets and splitters for module configurations.
Applications: Designed for modular I/O applications with fieldbus-independent configuration.
Overview: Provides technical specifications and configurations for the TURCK Modular Industrial I/O System BL 67.
Specifications:
  • Electrical: Operating current varies by module type.
  • Power Distribution: Inputs and logic powered by VMB and VI.
  • Material: Connectors made of nickel-plated brass, housings made of PC-V0 (Lexan).
Modules and Configurations:
  • Discrete Input/Output Modules: Include BL67-4DI4DO-PD with various configurations.
  • Analog Input Modules: Support voltage and current inputs with diagnostics.
  • Temperature Input Modules: Support thermocouples and RTD types with diagnostics.
  • Analog Output Modules: Support voltage and current outputs with diagnostics.
  • Serial Communication Modules: Support various serial communication protocols with diagnostics.
  • Power Feeding Module: Provides power distribution for downstream modules.
Diagnostics: Logical diagnostics through the fieldbus gateway, physical diagnostics include LEDs.
I/O Mapping: Detailed I/O data maps for each module type.
Base Modules: Describes various base modules with eurofast and picofast connectors.
Key Features:
  • Fieldbus Independent Configuration
  • IP 67 Protection
  • Various I/O Styles
See more

Catalog excerpts

Valves and Serial Bus Communication with Turck Modular I/O System-1

BULLETIN 600T ISO Valves and Serial Bus Communication with Turck Modular I/O System Premium Pneumatic Controls Since 1921 EtherNet/IPTM

 Open the catalog to page 1
Valves and Serial Bus Communication with Turck Modular I/O System-2

ROSS' website is the most complete and up-to-date source for product research and documentation. Search results produce downloadable documentation or request for quote (RFQ). Additional product information or CAD files are easily requested from Technical Service Team. Additional information such as certifications, links and associations is also available. Search for Products by Model Number, descriptions or Search Repair Kits by Product Model Number Visit our website for New released Products Industry Solutions section includes white papers, published articles, applications, and product selection...

 Open the catalog to page 2
Valves and Serial Bus Communication with Turck Modular I/O System-4

Standard Definitions 15407-1: Drop-cord Standards for Size 0 (26mm) & Size 00 (18mm) Wide Valves 15407-2: Plug-in Standards for Size 0 (26mm) & Size 00 (18mm) Wide Valves 5599-1: Drop-cord Standards for Sizes 1, 2, 3 5599-2: Plug-in Standards for Size 1, 2, 3 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from ROSS CONTROLS®, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users...

 Open the catalog to page 4
Valves and Serial Bus Communication with Turck Modular I/O System-5

Communication Adapter M12, Input or Output Module • Centralized Serial Bus system • Pneumatics and I/O are in close proximity to one another • I/O density per module = 8 • A complete Serial Bus communication offering for all ISO valves • UL, CE, CSA certifications (as marked)

 Open the catalog to page 5
Valves and Serial Bus Communication with Turck Modular I/O System-6

ISO Size 00 & 0 Valves Series W66 HOW TO ORDER (Choose your options (in red) to configure your valve model number.) Basic Size Solenoid Pilot Remote Pilot Solenoid Pilot Normally Open Normally Closed Non-Locking Overrides Plug-In (15407-2) Locking Overrides Single Non-Locking Overrides * Be sure to choose Options from the correct list. For example, if a Function of 4-Way 2-Position is chosen, then only choose Options from the section listed for that function. See the light gray-shaded columns of the Function and Options lists. Remote Pilot Locking Overrides Non-Locking Overrides Plug-In (15407-2)...

 Open the catalog to page 6
Valves and Serial Bus Communication with Turck Modular I/O System-7

Plug-in, Series W66 (15407-2) Size 00 (18mm) & Size 0 (26mm) 5/2 Valves – Single Solenoid Pilot ISO Port Valve Model Size Size Number* 4 Avg. Dimensions inches (mm) Weight CV Length Width Height lb (kg) * Sub-base not included. See page 10-17 for sub-bases, manifolds and accessories. 5/2 Valves – Double Solenoid Pilot ISO Port Valve Model Size Size Number* 4 Avg. Dimensions inches (mm) Weight CV Length Width Height lb (kg) * Sub-base not included. See page 10-17 for sub-bases, manifolds and accessories. 5/3 Valves – Double Solenoid Pilot Closed Center 4 Open Center ISO Port Valve Model Size Size...

 Open the catalog to page 7
Valves and Serial Bus Communication with Turck Modular I/O System-8

Spool and Sleeve Valves for ISO Sub-Bases (5599/II) Series W65 5/2 Valves – Single Solenoid Pilot Controlled, Spring Return Valve Model ISO Port Size Size Number* 4 Avg. Dimensions inches (mm) Weight CV Length Width Height lb (kg) * Sub-base not included. See page 11-17 for sub-bases, manifolds and accessories. 5/2 Valves – Double Solenoid Pilot Controlled, Detented Port ISO Size Size 4 Valve Model Number* Avg. Dimensions inches (mm) Weight CV Length Width Height lb (kg) * Sub-base not included. See pages 11-17 for sub-bases, manifolds and accessories. 5/3 Valves – Double Solenoid Pilot Controlled...

 Open the catalog to page 8
Valves and Serial Bus Communication with Turck Modular I/O System-9

Spool and Sleeve Valves for ISO Sub-Bases (5599/II) Series W65 5/2 Valves – Single Pressure Controlled, Spring Return Valve Model ISO Port Size Size Number* 4 2 14 Avg. Dimensions inches (mm) Weight CV A B C lb (kg) * Sub-base not included. See pages 11-17 for sub-bases, manifolds and accessories. 5/2 Valves – Double Pressure Controlled, Detented Valve Model ISO Port Size Size Number* 4 Avg. Dimensions inches (mm) Weight CV A B C lb (kg) * Sub-base not included. See pages 11-17 for sub-bases, manifolds and accessories. 5/3 Valves – Double Pressure Controlled 14 Power Center Closed Center Open...

 Open the catalog to page 9
Valves and Serial Bus Communication with Turck Modular I/O System-10

Plug-in, Series W66 (15407-2) Size 00 & 0 Manifold / Sub-Base Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.) R PS5511 13 M P Enclosures / Lead Length Mounting Style / Port Size Series W66, Size 00 Manifold with 1/8 NPT End Ports Manifold with 1/8 NPT Bottom / End Port Manifold with 1/8 BSPP Bottom / End Port Series W66, Size 0 Subbase with 1/4 NPT Side Ports Subbase with 1/4 BSPP Side Ports Subbase with 1/4 NPT Bottom / Side Port Subbase with 1/4 BSPP Bottom / Side Port Manifold with 1/4 NPT End Port Manifold with 1/4 BSPP End Port Manifold with 1/4 NPT...

 Open the catalog to page 10
Valves and Serial Bus Communication with Turck Modular I/O System-11

Plug-in, Series W65 (5599-2) Size 1, 2, & 3 Manifold / Sub-Base Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.) R PS4011 55 M C P Basic Series Size 1 Enclosures / Lead Length J† Circuit Board, Single Address Circuit Board, Double Address † Not Available with Subbase Kits. Note: When using the Enclosure / Lead Length “J” or “M” option: 12 volts DC - Maximum number of coils is 13 24 volts DC - Maximum number of coils is 21 120 volts AC - Coils limited by the number of pins available in the connector (25-Pin D-Sub = 24 coils, 19-Pin Brad Harrison = 16, 12-Pin...

 Open the catalog to page 11
Valves and Serial Bus Communication with Turck Modular I/O System-12

End Plate Kits, Series W66 & W65 Series W66 Size 00 & 0 End Plate Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.) Basic Series Thread Type End Plate Kit Type End Plate, Collective Wiring Series W65 Size 1, 2, & 3 End Plate Kits HOW TO ORDER (Choose your options (in red) to configure your valve model number.) Basic Series Engineering Level End Plate, Collective Wiring End Plate, Non-Collective Wiring ROSS CONTROLS®.

 Open the catalog to page 12
Valves and Serial Bus Communication with Turck Modular I/O System-13

Accessories Blank Stations, Port Isolation, Gaskets Blank Station Kits Size Kit includes: Blank Station Plate, Gasket, and Mounting Bolts. Kit includes: Blank Station Plate, Gasket, and Mounting Bolts. Manifold Port Isolation Kits Main Galley (1, 3, 5) Size Size 00 Size 0 Main Galley Size 00 Main Galley Kit includes: Plugs with O-rings. Kit includes: Plugs with O-rings. Manifold to Manifold Gasket Kits 15407-2 Size

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.