1. Catalogs
  2. ROSS Controls
  3. Series 1700 Skyline Replacement Valves

Series 1700 Skyline Replacement Valves

Series 1700 Skyline Replacement Valves

Series 1700 Skyline Replacement Valves

Product catalog summary
Overview: The Series 1700 Skyline Replacement Valves by ROSS CONTROLS are designed to replace existing Skyline valves without the need for adaptor plates. These valves are known for their durability and reliability, featuring the classic ROSS poppet design suitable for harsh environments.
Key Features:
  • Base-mounted valve with a proven track record.
  • Compatible with existing Skyline valve bases and manifolds.
  • Utilizes Series 2100 Type “O” internals, capable of withstanding temperatures as low as -40°F.
  • Accepts all ROSS LOGICAIR® adaptors.
Note: New bases and manifolds are not available.
Specifications:
  • Solenoid: Rated for continuous duty with standard voltages of 100-110V 50 Hz, 100-120V 60 Hz, 24V DC, and 110V DC.
  • Power Consumption: Single Solenoid – 87 VA inrush, 30 VA holding on 50 or 60 Hz; 14 watts on DC. Double Solenoid – Each solenoid; 190 VA inrush, 40 VA holding on 50 or 60 Hz; 20 watts on DC.
  • Temperature Range: Ambient: -40° to 120°F (-40° to 50°C). Media: -40° to 175°F (-40° to 80°C). Air must be free of water vapor below 40°F to prevent ice formation.
  • Flow Media: Filtered air, 5 micron recommended.
  • Inlet Pressure: 30 to 150 psig (2 to 10 bar).
  • Pilot Pressure: Must be equal to or greater than inlet pressure if using an external pilot supply.
Valve Types and Actuators:
  • 3/2 Valves - Small, Normally Closed and Midsize, Normally Open/Closed with options for Air Signal Actuator, Double Solenoid Pilot Actuator, and Single Solenoid Pilot Actuator.
  • 4/2 Valves - Available in Small, Midsize, and Large configurations.
Global Distribution: ROSS distributors are available worldwide to assist with product selection and support for both new users and those designing complex pneumatic systems.
Additional Information: The document includes a list of discontinued models and their replacement models. Note that Skyline Replacement Valves are made-to-order and may have longer shipping times. Standard ROSS warranty and cautions apply.
See more

Catalog excerpts

Series 1700 Skyline Replacement Valves-1

PRODUCT INFORMATION Series 1700 Skyline Replacement Valves The Series 1700 Skyline Valve has proven itself to be one of the most durable, lasting performers in the history of the pneumatics industry. Now ROSS gives users the opportunity to continue the tradition of superior performance and industrial strength by offering the Series 1700 Skyline Replacement Valve. Series 1700 Skyline Replacement Valve Features • • • • • • Durable base-mounted valve with proven record of excellence Mounts directly onto existing Skyline valve bases and manifolds without need for adaptor plates Series 2100 Type “O” internals which withstand temperatures as low as -40OF Classic ROSS poppet design which handles even the dirtiest environments Rugged ROSS reliability A Readily accepts all ROSS LOGICAIR® adaptors Note: New bases and manifolds not available. STANDARD SPECIFICATIONS: Solenoid: Rated for continuous duty. Standard Voltages: 100-110 volts 50 Hz; 100-120 volts 60 Hz; 24 volts DC; 110 volts DC. Power Consumption: Single Solenoid – 87 VA inrush, 30 VA holding on 50 or 60 Hz; 14 watts on DC. Double Solenoid – Each solenoid; 190 VA inrush, 40 VA holding on 50 or 60 Hz; 20 watts on DC. Ambient Temperature: -40° to 120°F (-40° to 50°C). Media Temperature: -40° to 175°F (-40° to 80°C). For temperatures below 40°F (4°C) air must be free of water vapor to prevent formation of ice. Flow Media: Filtered air, 5 micron recommended. Inlet Pressure: 30 to 150 psig (2 to 10 bar). Pilot Pressure: If external pilot supply is used, pressure must be equal to or greater than inlet pressure.

 Open the catalog to page 1
Series 1700 Skyline Replacement Valves-2

Series 1700 Skyline Replacement Valves 3/2 Valves - Small, Normally Closed Double Solenoid Pilot Actuator W Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator Single Solenoid Pilot Actuator 3/2 Valves - Midsize, Normally Open Double Solenoid Pilot Actuator VV Single Solenoid Pilot Actuator Air Signal Actuator Double Solenoid Single Solenoid Pilot Actuator 3/2 Valves - Midsize, Normally Closed Double Solenoid Pilot Actuator W Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator Single Solenoid Pilot Actuator ROSS CONTROLS'

 Open the catalog to page 2
Series 1700 Skyline Replacement Valves-3

Series 1700 Skyline Replacement Valves Double Solenoid Pilot Actuator VV Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator VV Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator VV Single Solenoid Pilot Actuator Double Solenoid Pilot Actuator Single Solenoid Pilot Actuator

 Open the catalog to page 3
Series 1700 Skyline Replacement Valves-4

Skyline Replacement Models for Discontinued Valves DISCONTINUED NOTE: Series 1700 Skyline Replacement Valves are available in “D” models (i.e. D1776F7309) with metric mounting bolts. Skyline Replacement Valves are made-to-order valves, and will take longer than made-to-stock items to ship. Additional information available upon request. SKYLINE BASES AND MANIFOLDS ARE NOT AVAILABLE. There are ROSS Distributors Throughout the World To meet your requirements across the globe, ROSS distributors are located throughout the world. Through ROSS or its distributors, guidance is available for the selection...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.