Line-Mount Valves
16Pages

{{requestButtons}}

Catalog excerpts

Line-Mount Valves - 1

Poppet Valves for Line Mounting and Valves for Vacuum Service • Manufacturers of Premium Pneumatic Controls since 1921 •

Open the catalog to page 1
Line-Mount Valves - 2

If you need products or specifications not shown within this bulletin, please contact ROSS for more information or visit ROSS website at www.rosscontrols.com. Features of ROSS Line-Mount Valves 1. Low weight; compact size. 2. LOGICAIR® adaptors provide special functions: • Timed sequence actuation and/or deactuation • Momentary control of actuation/deactuation from one pressure source • Actuating force multiplier, for use with low signal pressures. 3. Available with choices of internal components for three different temperature ranges. 4. Choose from five flow patterns: 2/2...

Open the catalog to page 2
Line-Mount Valves - 3

Series 27 Poppet Valves for Line Mounting Series 27 Poppet valves for line mounting are available with single or double solenoid pilot control, or an air head for pressure control. Valve elements have end-guided stainless steel stems. Flush flexible manual override buttons are standard on solenoid models. Solenoid models listed in this catalog use an internal pilot supply. They are, however, easily field-convertible for use with an external pilot supply. Models for external pilot supply may also be ordered from ROSS. FEATURES: • Poppet construction for near zero leakage & high dirt...

Open the catalog to page 3
Line-Mount Valves - 4

Series 27 Poppet Valves for Line Mounting Single Solenoid Pilot Controlled 2/2 Valves STANDARD SPECIFICATIONS: For valves on this page. Solenoids: AC or DC power. Standard Voltages: Consult ROSS. Power Consumption: 87 VA inrush, 30 VA holding on 50 or 60 Hz; 14 watts on DC. Ambient Temperature: 40° to 120°F (4° to 50°C). Media Temperature: 40° to 175°F (4° to 80°C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: 1/4 to 11/2 Port Sizes: 15 to 150 psig (1 to 10 bar); 11/2 to 21/2 Port Sizes: 30 to 150 psig (2 to 10 bar). Pilot Pressure: When external supply is used, pressure...

Open the catalog to page 4
Line-Mount Valves - 5

Series 27 Poppet Valves for Line Mounting Single Pressure Controlled 2 STANDARD SPECIFICATIONS: For valves on this page. Ambient/Media Temperature: 40° to 175°F (4° to 80°C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: 1/4 to 11/2 Port Sizes: 15 to 150 psig (1 to 10 bar). 11/2 to 21/2 Port Sizes: 30 to 150 psig (2 to 10 bar). Pilot Pressure: Must be equal to or greater than inlet pressure. Threads: Model numbers above specify NPT pressure port threads. For other threads, consult ROSS. IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside...

Open the catalog to page 5
Line-Mount Valves - 6

Series 27 Poppet Valves for Line Mounting 4/2 Valves – Double Direct Solenoid Controlled, Detented Dimensions inches (mm) Port Sizes Valve Model Avg. A B C In-Out Exh. Number CV 1/4 1/2 3/8 1/2 1/2 1/2 STANDARD SPECIFICATIONS: For valves listed above. Solenoids: AC or DC power. Standard Voltages: Consult ROSS. Power Consumption: Each solenoid; 190 VA inrush, 40 VA holding on 50 or 60 Hz; 20 watts on DC. Indicator Lights: In each solenoid housing. Ambient Temperature: 40° to 120°F (4° to 50°C). Media Temperature: 40° to 175°F (4° to 80°C). Flow Media: Filtered air; 5 micron recommended....

Open the catalog to page 6
Line-Mount Valves - 7

Series 21 Poppet Valves for Line Mounting Series 21 High Temperature and Low Temperature Service Series 21 valves are configured like the Series 27 valves, but are designed with metal internals and special seals appropriate for use in more extreme temperatures. The valves are designated as either Type H (High Temperature) or Type O (Low Temperature) valves. Temperature specifications for the two types are given below. Solenoid models listed in this catalog use an internal pilot supply. They are, however, easily field-convertible for use with an external pilot supply. Models for external...

Open the catalog to page 7
Line-Mount Valves - 8

Series 21 Poppet Valves for Line Mounting Single Solenoid Pilot Controlled 2/2 Valves 2 Valve Model Number Port A Type H Type O Size NC NO NC NO Valve Model Number Type H Type O NC NO NC NO Port Sizes In-Out Exh. Valve Model Number Avg. Dimensions inches (mm) Weight A B C lb (kg) CV STANDARD SPECIFICATIONS: See page 7. IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.

Open the catalog to page 8
Line-Mount Valves - 9

Series 21 Poppet Valves for Line Mounting Single Pressure Controlled 2/2 Valves Valve Model Number Port Type H Type O Size NC NO NC NO Valve Model Number A Type H Type O NC NO NC NO 2153B2001 2153B3001 2153B4011 2153B4001 2153B5001 2153B6011 2153B6001 2153B7001 2153B8011 Port Sizes I n-Out xh. E STANDARD SPECIFICATIONS: For valves on this page. Ambient/Media Temperatures: Type H: 0° to 300°F (-17° to 150°C). Type O: -40° to 175°F (-40° to 80°C). For temperatures below 40°F (4°C) air must be free of water vapor to prevent formation of ice. Flow Media: Filtered air; 5 micron recommended....

Open the catalog to page 9
Line-Mount Valves - 10

Series 21 Poppet Valves for Line Mounting 4/2 Valves – Double Direct Solenoid Controlled, Detented Dimensions inches (mm) Port Sizes Valve Model Avg. A B C In-Out Exh. Number CV 1/4 1/2 STANDARD SPECIFICATIONS: For valves listed above. Solenoids: AC or DC power. Standard Voltages: Consult ROSS. Power Consumption: Each solenoid; 190 VA inrush, 40 VA holding on 50 or 60 Hz; 20 watts on DC. Indicator Lights: In each solenoid housing. Ambient Temperature: 40° to 120°F (4° to 50°C). Media Temperature: 40° to 175°F (4° to 80°C). For temperatures below 40°F (4°C) air must be free of water vapor to...

Open the catalog to page 10
Line-Mount Valves - 11

Anatomy of a Vacuum Service Valve Special ROSS poppets are the toughest available, ideal for dirty vacuum applications. ROSS poppets also have large flow areas, which allow high flow. Pilot can be fed to port X-1 externally by compressed air. Internally, atmospheric pressure can be used as pilot for “full vacuum” version. ROSS vacuum valves have larger orifices, allowing greater flow and easing the transport of air even though there is a small differential between the vacuum within the valve and atmospheric pressure outside the valve. Typical applications place vacuum or atmosphere on port...

Open the catalog to page 11

All ROSS Controls catalogs and technical brochures

  1. safety product

    32 Pages

  2. DM2

    4 Pages

  3. MD3

    16 Pages

  4. CM series

    4 Pages

  5. DM2 Series D

    16 Pages

  6. W60

    4 Pages

  7. foot valves

    1 Pages

  8. manual valve

    12 Pages

  9. safety valve

    13 Pages

  10. FRL ROSS

    12 Pages

  11. poppet valve

    16 Pages

  12. TSSA

    48 Pages

Archived catalogs