CM series
1 /4Pages

CM series

CM series
1 /4Pages

Catalog excerpts

CM series-1

PRODUCT DATA SHEET INFORMATION 5/2 Pressure Return - CrossMirror® Series Double Valves Solenoid Pilot Controlled FEATURES: • Can be used as 3/2 Normally Closed or Normally Open valve function by plugging the unused outlet port • Self-contained dynamic monitoring system; no additional monitoring required • Valve fault results in a lockout condition and prevents unintentional reset with removal of air or electricity • Reset can be electrical solenoid or remote pneumatic signal • Status indication switch (ready-to-run) to inform machine controller of valve condition • Base mounted, stainless steel spool valve construction • Manifoldable for multi valve applications • Sistema library data pending APPLICATIONS: Cylinder Return to Home Position. • Two hand control EN574 Type III C • Pinch point applications • Shearing equipment • Forming applications • Cutting applications • Clamping applications ISO 13849-1:2006 Category 4 PL e applications Pending Ordering Information Valve and base assembly with remote reset Model Number* CM26PNA00**1X Pressure Switch * Model number includes base supplied with NPT threads. For BSPP threads, replace “N” with a “D” in the model number, e.g., CM26PDA00A1X. ** Insert voltage code: “A” = 24 volts DC; “B” = 110 volts AC, 50/60 Hz. e.g., CM26PNA00A1X, CM26PNA00B1X. Port Sizes Standard Specifications Pilot Solenoids: According to VDE 0580. Enclosure rating according to DIN 400 50 IP 65. Three solenoids, rated for continuous duty. Standard Voltages: 24 volts DC, 110 volts AC, 50/60 Hz. Pilot Solenoids Power Consumption (each solenoid): 24 volts DC: 1.2 watts on DC, 38.0 mA holding. 110 volts AC: 55.1 mA inrush current, 49.5 mA holding current, 5.4 volt amps. Ambient Temperature: 15° to 122°F (-10° to 50°C). Media Temperature: 40° to 175°F (4° to 80°C). Flow Media: Filtered, lubricated or unlubricated (mineral oils according to DIN 51519, viscosity classes 32-46); 5-micron recommended. Inlet Pressure: 40 to 150 psig (2.7 to 10 bar). Pressure Switch (Status Indicator) Rating: 5 amps at 250 volts AC, or 5 amps at 30 volts DC. Monitoring: Dynamically, cyclically, internally during each actuating and de-actuating movement. Monitoring function has memory and requires an overt act to reset unit after lockout. Solenoid Reset: Units with solenoid reset include a 3/2 solenoid valve. Energize this solenoid momentarily to reset valve after lock-out condition occurs. Remote Reset: Remote signal to be supplied by customer’s 3/2 valve (connect remote signal line to remote RESET port in valve). Apply signal momentarily to reset valve after fault conditions occurs. NOTE: Main solenoids must be off when performing reset procedure. Electrical Connectors: Form C electrical connectors, with or without the light. Port Threads: NPT, BSPP. Product data for Sistema Library users, pending. This valve is not designed for use in power press clutch/brake applications. ROSS CONTROLS®

 Open the catalog to page 1
CM series-2

PRODUCT DATA SHEET INFORMATION 5/2 Pressure Return – CrossMirror® Series Double Valves VALVE OPERATION Normal Operation: The valve is operated by energizing both pilot solenoids simultaneously. This causes both main valve elements to be actuated so that air from inlet port 1 flows to outlet port 4, but not to port 2. Air downstream of port 2 is exhausted through port 3. When the solenoids are de-energized, both valve elements are de-actuated, and air then flows from inlet port 1 to outlet port 2, but no longer to outlet port 4. Air downstream of port 4 is exhausted through port 5. On first operation,...

 Open the catalog to page 2
CM series-3

PRODUCT DATA SHEET INFORMATION 5/2 Pressure Return - CROSsMlRROR® Series Double Valves Product Dimensions - inches (mm) Valve and base assembly, with remote reset and without pressure switch. VALVE ASSEMBLY BASE ASSEMBLY Valve and base assembly, with remote reset and pressure switch. VALVE ASSEMBLY BASE ASSEMBLY Valve and base assembly, with solenoid reset reset and without pressure switch. VALVE ASSEMBLY -BASE ASSEMBLY Valve and base assembly, with solenoid reset and pressure switch. VALVE ASSEMBLY -BASE ASSEMBLY

 Open the catalog to page 3
CM series-4

Sub-Bases and Manifold Assemblies for CrossMirror® Series Valves In addition to the manifold stations, an end station kit with a check valve must be ordered for each assembly. The number of manifolds with a single supply inlet will be limited to the pressure and flow rate of the system. Too many manifolds may result in too large of an internal pressure drop resulting in valve faults. The manifold end station kit with dual inlet check will allow the manifold to be supplied with air from both ends of the assembly. Port Size Manifold End Plate w/ Check Valve Kit Number Dual Supply Manifold End Plate...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.