1. Catalogs
  2. Rosenberger OSI
  3. Fiber Optic cables

Fiber Optic cables
1 /7Pages

Fiber Optic cables

Fiber Optic cables
1 /7Pages

Catalog excerpts

Fiber Optic cables-1

gem DIN/VDE 0888, IEC 60794-2ANWENDUNGSBEREICHE Simplex- und Duplex-Kabel: acc. to DIN/VDE 0888, IEC 60794-2Applications Simplex and duplex cables: 䟕Pigtails, Patchkabel und Gerteanschlukabael 䟕Etagenverkabelung (tertir: horizontal in Etage = FTTD)gem䤟 ISO/IEC 11801 und DIN EN 50173-2 pigtails, patch cords and equipment cords Օ floor cabling (tertiary: horizontal in floor = FTTD)acc. to ISO/IEC 11801 and DIN EN 50173-2 Mini-Break-Out und Break-Out-Kabel: Schrank ջ Schrank-Verbindungen Punkt zu Punkt-Verbindungen (Aktiv ջ Aktiv) Etagenverkabelung (tertiդr: horizontal in Etage = FTTD)gem ISO/IEC 11801 und DIN EN 50173-2 Mini-break-out and break-out cables: 䟕 rack-to-rack connections point -to-point connections (active ջ active) floor cabling (tertiary: horizontal in floor = FTTD)acc. to ISO/IEC 11801 and DIN EN 50173-2 Installation Օ indoor only in plastic pipes and ducts Օ conditionally at cable support systems (crush sensitivity!) conditionally in raised floors (crush sensitivity!) Օ in distribution racks and active devicesFlame retardancy VERLEGUNGnur In-HausՕin Kunststoffrohren und Kanlen bedingt auf Kabeltragsystemen (Quetschgefahr!) 䕕bedingt in Doppelbden (Quetschgefahr!) in Verteilschr敤nken und AktivgertenBRANDVERHALTENschwer entflammbar䕕keine Emission von Korrosionsgasen nach IEC 60754-2 geringe Rauchgasemission nach IEC 61034-2 Օgeringe BrandfortleitungKABELEIGENSCHAFTENAu՟enmantel aus FR-LSZH-Material (Flame RetardantLow Smoke Zero Halogen)erhնhte Zugfestigkeit durch nichtmetallischeZugentlastungselementeAdern fռr die direkte Steckermontage vor Ort Standardfarben:SM= gelbMM= orange MM OM3 = aqua (tռrkis)andere auf Anfrage flame-retardant Օ no corrosive gas emission acc. to IEC 60754-2 low smoke emission acc. to IEC 61034-2Օlow fire spreadingProperties outer sheath made of FR-LSZH-material(Flame Retardant Low Smoke Zero Halogen) Օ increased tensile strength by use of non-metallicstrain-relief elements fibers to install connectors on site Օ Standard colors:SM= yellowMM= orange MM OM3 = aqua (turquoise)others on request >

 Open the catalog to page 1
Fiber Optic cables-4

Profile view: Design: Optical fibre E9/125 m, matched cladding type (conform to CCITT Rec. G. 652 and IEC 60793-2-50 type B1.1) with optical core and optical cladding 125 յm +/- 1 m (on request +/- 1 յm) Primary acrylate coating, 245 m +/- 5 յm diameter > Geometrical properties: Modefield diameter (at 1310 nm) 9.2 +/- 0.4 m Cladding noncircularity < 1 % Mode field concentricity error < 0.8 յm Eccentricity of coating < 10 m Screen test 1 % stretching at 1 s (100 kpsi) Transmission characteristics: Zero dispersion wavelength 1300 nm-1322 nm Zero dispersion slope բɤ 0.093 ps/nm > 2 x km Cut-off...

 Open the catalog to page 4
Fiber Optic cables-5

Design: Optical fibre G50/125 m (conform to CCITT Rec. G. 651 and IEC 60793-2-10 type 1Aa) with optical core 50 յm +/- 2.5 m diameter and optical cladding 125 յm +/- 2 m diameter Primary acrylate coating, 245 յm +/- 10 m diameter Geometrical properties: Core concentricity error < 5 % Coating concentricity error < 1 % Core coating eccentricity < 1.5 յm Eccentricity of coating < 10 m Screen test 1 % stretching at 1 s (100 kpsi) Transmission characteristics: Attenuation, maximum values 850 nm 2.7 dB/km 1300 nm 0.7 dB/km Bandwidth (Overfilled launch) 850 nm 600 MHz x km min. 1300 nm 1200 MHz x km...

 Open the catalog to page 5
Fiber Optic cables-6

Design: Optical fibre G50/125 m (conform to CCITT Rec. G. 651 and IEC 60793-2-10 type 1Aa) with optical core 50 յm +/- 2.5 m diameter and optical cladding 125 յm +/- 2 m diameter Primary acrylate coating, 245 յm +/- 10 m diameter Geometrical properties: Core concentricity error < 5 % Coating concentricity error < 1 % Core coating eccentricity < 1.5 յm Eccentricity of coating < 10 m Screen test 1 % stretching at 1 s (100 kpsi) Transmission characteristics: Attenuation, maximum values 850 nm 2.5 dB/km 1300 nm 0.7 dB/km Bandwidth (OFL), minimum values 850 nm 1500 MHz x km 1300 nm 500 MHz x km Effective...

 Open the catalog to page 6
Fiber Optic cables-7

Profile view: Design: Optical fibre G62.5/125 m (following CCITT Rec. G. 651 conform to IEC 60793-2-10 type 1Ab) with optical core 62.5 յm +/- 3 m diameter and optical cladding 125 յm +/- 2 m diameter Primary acrylate coating, 245 յm +/- 10 m diameter Core concentricity error < 5 % Coating concentricity error < 1 % Core coating eccentricity < 1.5 յm Eccentricity of coating < 10 m Screen test 1 % stretching at 1 s (100 kpsi) Geometrical properties: Attenuation, maximum values 850 nm 3.2 dB/km 1300 nm 0.9 dB/km Bandwidth (Overfilled launch) 850 nm 250 MHz x km min. 1300 nm 600 MHz x km min. Numerical...

 Open the catalog to page 7

All Rosenberger OSI catalogs and technical brochures

  1. PIGTAILS

    1  Page

  2. FO-COUPLERS

    2  Pages

  3. MTP^/MPO

    1  Page

  4. MT-RJ

    1  Page

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.