T37-B1

T37-B1

T37-B1

Product catalog summary
Technical Specifications:
The GDRF5 120x126L is a double inlet centrifugal fan with an electronic commutation motor. It operates at a voltage of 230V and a frequency of 50/60Hz, with a current of 0.50A and a maximum current of 0.69A. The power consumption is 57W, with a maximum of 84W, and it rotates at 1915 RPM. The operational temperature range is from -20°C to +60°C.
Marking & Standards:
The product complies with CE RT7192CE and EN 60335-2-80:2003 standards, including amendments A1:2004 and A2:2009. It is manufactured in accordance with EN 60335-1 and the RoHS directive 2015/863/CE. The IP class is determined by EN 60034-5 standards.
Technical Data:
The fan weighs 2.00 kg and is classified as Class F with a protection level of IP54, indicating protection against dust and splashing water. It features electronically protected motors and uses 2 ball bearings (608ZZ). The balance level is G2.5, and the rotor is protected by electrolytic galvanizing.
Additional Data:
Accessories include a finger guard (21237). Documentation includes an operating and recycling manual available online. The product is not applicable under the ErP Directive (EU 2009/125/EC) as its power at optimum energy efficiency is below 125W.
Performance Data:
The fan's performance is measured according to ISO 5801, with air performance data provided for various operational settings. The intake-side sound level is measured according to ISO 3744, with LpA values given at a 1m distance from the fan axis.
Graphical Data:
The document includes a graph showing the relationship between static pressure and airflow, measured in both cfm and m³/h, under specified conditions.
See more

Catalog excerpts

T37-B1-1

Technical data sheet Model T37-B1-1 Revision 0 Revision 02/2021 Designation Double inlet centrifugal fans with electronic commutation motor ELECTRICAL DATA Tension (V) Power (W) Maximum power (W) MARKING & STANDARDS The product is manufactured in accordance with EN 60335-1, and RoHS directiv 2015/863/CE IP class according to EN 60034-5 to be checked with operation and installation Issued: 2021-02-15 at 11:28 Documentations and pictures are non contractual, all the data of the technical file and the drawing are subject to change. ROSENBERG VENDOME SAS Z.I SUD | Rue Marc Seguin | BP60008 | F-41401 | VENDOME Cedex Tel. +33 (0)2 54 23 14 54 Fax +33 (0)2 54 72 22 72 RC BLOIS B 308 172 147 000 32 www.ecofit.com | [email protected]

 Open the catalog to page 1
T37-B1-2

Technical data sheet Model T37-B1-1 TECHNICAL DATA Description Weight: 2.00 kg Class F Protection level: 54 | Protection against ingress of dust / Protection against ingress of water : splashing Motor’s protection Electronically protected Bearing type: 2 ball bearings 608ZZ Balance level: G2.5 Wiring diagram Finishes Rotor electrolytic galvanizing protection Galvanized scroll and frame The product is manufactured in accordance with EN 60335-1, and RoHS directiv 2015/863/CE IP class according to EN 60034-5 to be checked with operation and installation Issued: 2021-02-15 at 11:28 Documentations...

 Open the catalog to page 2
T37-B1-3

Technical data sheet Model T37-B1-1 ADDITIONAL DATA Accessories Operating and recycling manual http://www.ecofit.com/anglais/normes Measurement setup Scroll 15211-a Vol VSD120x146 GAL ERP DATA ErP Directive ErP (EU 2009/125/EC) not applicable: Power at optimum energy efficiency point <125W The product is manufactured in accordance with EN 60335-1, and RoHS directiv 2015/863/CE IP class according to EN 60034-5 to be checked with operation and installation Issued: 2021-02-15 at 11:28 Documentations and pictures are non contractual, all the data of the technical file and the drawing are subject...

 Open the catalog to page 3
T37-B1-4

Technical data sheet Model T37-B1-1 TECHNICAL DATA Pression statique / Static Pressure [Pa] Pression statique / Static Pressure [In.W] Mesures / Measured Values* Un (V) * Air performance measured according to: ISO 5801, installation category C. Intake-side sound level: according to ISO 3744, LpA measured at 1 m distance from fan axis. The values given are only applicable under the specifi ed measuring conditions and may differ depending on the installation conditions. In the event of deviation The product is manufactured in accordance with EN 60335-1, and RoHS directiv 2015/863/CE IP class according...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.