Product catalog summary
Introduction
ROSENBERG VENDOME, founded in 1976, specializes in motors and fans, expanding its product line in 1981 to include external rotor motors and fans. The company is ISO 9001:2015 certified and part of the ROSENBERG group since 1994. It acquired ETRI in 2002 and introduced energy-saving fans in 2007. The company exports 80% of its production, with 40% going outside the EU.
External Rotor Motor
These motors are compact and allow speed control via voltage variation. The motor's placement in the fan air stream ensures continuous cooling, enhancing efficiency.
Application Instructions
ECOFIT products require professional installation with proper electrical and mechanical protection. Suitable capacitors must be used, and three-phase motors need external protection. Fans should operate within specified limits and are designed for clean air with a maximum relative humidity of 80%.
Product Improvement Policy
ROSENBERG VENDOME reserves the right to make design changes without notice. The catalogue data is non-contractual.
Installation and Compliance
Products must be installed by professionals ensuring compliance with machinery, EMC, and low voltage directives.
Technical Specifications
Performance data for ECOFIT fans is measured at maximum flow rates according to ISO EN ISO 5801 standards. Fans should not be used outside specified performance curves to avoid overheating.
Sound Levels
Measured according to ISO 3744 and expressed as 'A' weighted acoustic pressure.
Life Expectancy
ECOFIT motors and fans have a life expectancy between 30,000 and 70,000 hours, depending on conditions.
Electrical Insulation and Protection
ECOFIT motors use Class F insulation. Single-phase AC motors have thermal protection, while three-phase AC motors do not. EC fans are protected by their electronics.
Mechanical Protection
Protection degrees range from IP20 to IP54. Final validation must be performed by the client.
Temperature Range
The minimum ambient temperature is -20°C. Maximum temperatures vary based on operating conditions.
Balancing and Rotation
Motors are dynamically balanced according to ISO 21940-11:2016. Rotation direction is indicated as 'R' or 'L'.
Speed Control
ECOFIT AC motors are suitable for speed control via voltage variation, with best results using auto-transformers.
Approvals
ECOFIT motors and fans are CE and UKCA marked, with options for UL and CSA approvals.
Specifications and Standards
ECOFIT fans and motors are manufactured under ISO 9001:2015 quality standards. Voltage waveform control is crucial to prevent motor damage.
Special Designs
ROSENBERG VENDOME offers product customization based on catalog references or client specifications.
Fan Selection
Key criteria include dimensional constraints, required airflow/pressure, noise level, and electrical supply constraints.
Normative Information
Compliance with EMC 2014/30 EEC and LVD 2014/35 EEC directives is outlined.
Product Range
Introduces centrifugal impellers and fans, customizable for various specifications.
Specifications
Details single inlet centrifugal fans with Class F and IP44 protection.
Technical Data
Provides specifications for various fan models, including voltage, frequency, power consumption, airflow, speed, noise level, and temperature range.
Models and Performance
Lists several models with performance metrics.
Notes
The document is non-contractual, intended for professional use only.
Overview
Provides technical specifications and guidelines for centrifugal fans.
Specifications
Details various models of centrifugal fans, including dimensions, power requirements, and operational temperature ranges.
Procedures and Recommendations
Emphasizes adhering to specified pressure levels to prevent motor overheating.
Technical Data
Tables provide detailed technical data for various fan models.
Standards and Safety
Fans are designed with safety features and compliant with balancing standards.
Technical Specifications
Details specifications for double inlet centrifugal fans.
Performance Data
Lists various models with specifications.
Models and Variants
Details several models with specific performance characteristics.
Important Notes
The document is non-contractual, intended for professional use only.
Technical Specifications
Details specifications for double inlet centrifugal fans with backward curved impellers.
Performance and Usage
Fans operate at voltages between 200-277V and frequencies of 50/60Hz.
Environmental and Safety Considerations
Maximum operating temperature ranges from -20°C to +60°C.
Additional Information
The document is non-contractual, intended for professional use only.
Overview
Provides technical specifications and details for backward curved centrifugal fans.
Specifications
Fans are designed with high efficiency and optimized power consumption.
Technical Data
Lists fan models with voltage, frequency, power consumption, airflow capacity, rotational speed, noise level, and operating temperature range.
Connection Diagrams
Includes multiple connection diagrams for different fan models.
Important Notes
This is a non-contractual document, intended for professional use only.
Technical Specifications
Details specifications for backward curved centrifugal fans.
Performance Data
Lists various models with performance data.
Protection and Construction
Fans are designed with electronic motor protection and durable materials.
Usage and Application
The catalogue is intended for professional use only.
Technical Specifications
Details specifications for backward curved centrifugal fans.
Performance Data
Lists various models with performance data.
Mechanical Construction
Fans feature a mechanically robust design.
Protection and Safety
Fans are equipped with IP44 or IP54 protection.
Additional Features
Notes that all data is subject to change without prior notice.
Overview
Provides technical specifications and features of various models of backward curved centrifugal fans.
Specifications
Fans are classified under F Class with IP4x protection.
Performance Data
Lists various models with specific technical data.
Key Features
Fans are designed for high efficiency and safety.
Technical Specifications
Details specifications for various models of backward curved centrifugal fans and axial fans.
Operating Conditions
Fans are designed to operate within a temperature range of -20°C to +60°C.
Product Range
Outlines a range of axial fans with different configurations.
Usage Recommendations
Recommends testing motor temperature under worst-case conditions.
Non-Contractual Notice
All data is subject to change without prior notice.
Overview
Provides technical specifications and connection diagrams for various models of axial fans.
Specifications
Fans are classified under F Class with IP44 protection.
Technical Data
Lists various models with their respective technical data.
Connection Diagrams
Several connection diagrams are referenced.
Non-Contractual Notice
All data is subject to change without prior notice.
Overview
Provides technical specifications and data for various models of axial fans.
Specifications
Lists multiple fan models with specific electrical and performance characteristics.
Mechanical Construction
Fans feature IP44 protection and electronic motor protection.
Recommendations
Ensure compatibility with electrical specifications before installation.
Additional Notes
All data is for professional use only and may be updated without prior notice.
Technical Specifications
Provides technical specifications for axial fans.
Performance Data
Lists various models of axial fans with detailed performance data.
Protection and Construction
Fans are designed with electronic motor protection and durable materials.
Usage and Application
This catalogue is intended for professional use only.
Introduction
Non-contractual catalogue for ECOFIT cross flow fans and external rotor motors.
Cross Flow Fans
Designed for air conditioning, heating, and cooling applications.
Specifications
Standard construction includes a zinc-coated steel scroll housing and an aluminum wheel.
Conditions of Use
Users must ensure proper ventilation to avoid motor overheating.
External Rotor Motors
Available in IP20 or IP44 ratings.
Standard Specifications
Motors feature Cl.F windings protected by impedance or thermal cut-out.
Conditions of Use
Motors should not be overloaded and must be installed in well-ventilated areas.
Overview
Includes a part number list with descriptions and wiring diagrams.
Overview
Provides technical specifications and accessory details for ECOFIT external rotor motors.
Specifications
Lists various motor models with their respective codes and specifications.
Accessories
Details several accessories, including regulators, inlet cones, and finger guards.
Regulators
Designed for use with ECOFIT motorized backward wheels.
Inlet Cones
Essential for achieving declared performance levels.
Finger Guards
Used to protect fans from foreign objects.
Capacitors
Various capacitors are listed with their specifications.
Boxes and Connectors
Details on boxes and connectors include material and standards.
Autotransformers
Described with their output voltage levels and compatibility.
Important Notes
All data is for informational purposes only and subject to change.
Specifications and Materials
Details various industrial accessories made from different materials.
Non-Contractual Nature
The document is non-contractual, meaning all data and images are for informational purposes only.
General Sales Conditions
Outlines the general sales conditions of ROSENBERG VENDOME.
Delivery and Transport
Delivery deadlines are based on the information available at the time of order.
Pricing and Payment
Prices are set ex-works and may be revised due to changes in raw material costs.
Retention of Ownership
Ownership of goods remains with the seller until full payment is received.
Guarantees
Standard catalog products are guaranteed for one year from the date of delivery.
Payment Terms
Payment terms cannot exceed 45 days from the end of the month or 60 days from the invoice receipt.
Guarantees
Standard products are guaranteed for one year from delivery for normal use.
Intellectual Property
ROSENBERG VENDOME retains full ownership of all technical documents provided to customers.
Liability and Insurance
ROSENBERG VENDOME ensures product conformity to specifications but is not responsible for the final results.
Legal Jurisdiction
French law governs sales, and disputes are subject to the jurisdiction of the seller's local commercial court.
See more

Catalog excerpts

ECOFIT catalogue MOTORS and FANS-1

MOTEURS ET VENTILATEURS MOTORS AND FANS MOTOREN UND VENTILATOREN

 Open the catalog to page 1
ECOFIT catalogue MOTORS and FANS-2

Ventilateurs centrifuges à action simple ouïe Single inlet centrifugal fans Einseitig saugende Radialventilatoren Ventilateurs centrifuges à action double ouïe Double inlet centrifugal fans Doppelseitig saugende Radialventilatoren Ventilateurs centrifuges à réaction Backward curved centrifugal fans Ventilatoren mit Rückwärts gekrümmten Laufrädern Ventilateurs axiaux Axial fans Axial Ventilatoren Ventilateurs pour air chaud Fans for hot gases Warmluftventilatoren Ventilateurs tangentiels Cross flow fans Querstromgebläse Moteurs à rotor extérieur External rotor motor Außenläufermotoren Accessoires...

 Open the catalog to page 2
ECOFIT catalogue MOTORS and FANS-3

Sommaire / Summary / Inhaltsverzeichnis 146 200 148 250 150 300 152 350 154 VIROLE CARREE 200 155 250 156 AC TRIPHASE 2 POLES 200 158 250 160 300 162 AC TRIPHASE 4 POLES 200 164 250 166 300 168 200 EC 170 250 172 300 174 350 176 400 178 Ventilateurs pour air chaud / Fans for hot gases / 178 Warmluftventilatoren 182 Ventilateurs tangentiels / Cross flow fans / Querstromgebläse 186 Moteur à rotor extérieur / External rotor motor / 186 Außenläufermotoren 190 Accessoires / Accessories / Zubehör 202 Conditions générales de vente / General sales conditions / Allgemeine Verkaufsbedigungen (E.V.CO009d)...

 Open the catalog to page 3
ECOFIT catalogue MOTORS and FANS-4

Introduction / Introduction / Einleitung SAVOIR FAIRE - VALEUR AJOUTEE SUR MESURE - QUALITÉ Créée en 1976, ROSENBERG VENDOME conçoit, fabrique et commercialise des moteurs et des ventilateurs. Dès 1981, ROSENBERG VENDOME étoffe sa gamme avec des moteurs et ventilateurs à rotor extérieur. Ce concept est à la base du succès technique et commercial de ces 40 dernières années. Certifié ISO 9002 depuis 1993, le système qualité ROSENBERG VENDOME est maintenant certifié ISO 9001 version 2015. Depuis 1994, ROSENBERG VENDOME appartient au groupe ROSENBERG. En mars 2002, ROSENBERG VENDOME acquiert ETRI,...

 Open the catalog to page 4
ECOFIT catalogue MOTORS and FANS-5

Le moteur à rotor extérieur / The external rotor motor / Außenläufermotoren La technologie du rotor extérieur est particulièrement intéressante pour motoriser des ventilateurs : - construction compacte. - roue ou hélice fixée directement sur le rotor, l‘ensemble étant équilibré solidairement. - moteur généralement situé dans le circuit d’air, ce qui assure un bon refroidissement et une puissance massique optimale. Axe de rotation Rotation shaft Welle External rotor motors are particularly advantageous in the construction of fans. They are compact dimensionally and are speed controllable by voltage...

 Open the catalog to page 5
ECOFIT catalogue MOTORS and FANS-6

Instructions de montage et d’utilisation / Application instructions / Montage- und Bedienungsanleitung - Les produits de marque ECOFIT sont destinés à être installés par des professionnels qui doivent s’assurer du respect des directives machines, compatibilités électromagnétiques et directives basse tension. - Les équipements de protection mécanique et électrique doivent être définis et installés dans les règles de l’art. - Les condensateurs doivent être choisis en respectant les valeurs de capacités et de tensions appropriées. - Les moteurs triphasés doivent être connectés à un système de protection...

 Open the catalog to page 6
ECOFIT catalogue MOTORS and FANS-7

Données techniques / Technical data / Technische Daten Débit/pression : Les données techniques des ventilateurs ECOFIT décrits dans ce catalogue ont été relevées au débit maximum autorisé. Les courbes de débit/pression statique sont mesurées à l’aspiration en utilisant le banc de mesures ci-dessous selon la norme ISO EN ISO 5801. Les courbes obtenues montrent la hausse de pression en fonction du débit d’air et sont valides pour une densité d’air de 1,2 Kg/m3 avec une température de 20°C. Les courbes de performances ont été relevées en installation de type «A» (entrée et sortie d’air libres)....

 Open the catalog to page 7
ECOFIT catalogue MOTORS and FANS-8

Données techniques / Technical data / Technische Daten Durée de vie : Les moteurs et ventilateurs ECOFIT décrits dans ce catalogue sont montés sur roulements à billes, ce qui autorise un fonctionnement dans toutes les positions. La durée de vie L10 est comprise entre 30 000 et 70 000 heures, en fonction de la température de l’air transporté et du point d’utilisation du ventilateur. Sur demande, un calcul théorique de cette durée de vie peut être effectué. Life expectancy : The ECOFIT motors and fans described in this catalogue are fitted with ball bearings for use in any mounting attitude. L10...

 Open the catalog to page 8
ECOFIT catalogue MOTORS and FANS-9

Données techniques / Technical data / Technische Daten Variation de vitesse : Les moteurs AC à rotor extérieur ECOFIT sont particulièrement bien adaptés à la variation de vitesse par pilotage de la tension. Les meilleurs résultats sont obtenus avec des autotransformateurs. Si le pilotage de la tension est assuré par un variateur électronique, il est impératif de s’assurer que le signal délivré ne risque pas d’endommager le moteur. De même, les signaux délivrés par un variateur de fréquence doivent être filtrés de façon appropriée pour éviter d’endommager le moteur. Voir également le chapitre...

 Open the catalog to page 9
ECOFIT catalogue MOTORS and FANS-10

Des solutions adaptées / Adapted solutions / Angepasste Lösungen Exécutions spéciales : Sur demande, nous pouvons définir un produit spécifique à partir d’une référence catalogue ou d’un cahier des charges client. Peuvent être adaptés : - la tension en AC, de 100 à 480Volts. - la tension en DC : nous consulter. - la fréquence pour 50 et 60Hertz. - les normes pour CE et UKCA ou ULCSA. - le débit et la pression. - la température admise par le moteur de - 40 à +80°C. - la géométrie et la finition du ventilateur. - la classe de protection. - le taux d’humidité. - la multivitesse par bobinage, par...

 Open the catalog to page 10