ROSE Systemtechnik GmbH In 1969 ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany. Today ROSE is one of the world’s leading and innovative providers of industrial enclosure system engineering, employing over 350 people at the German headquarter. In association with Phoenix Mecano AG, Switzerland, we develop and manufacture high-quality industrial enclosures and system solutions for areas such as mechanical and plant engineering, automation engineering, potentially explosive atmospheres, instrumentation, control and automation technology, as well as the foodstuff and beverage...

Open the catalog to page 2
OPERATING AND DISPLAY ENCLOSURES - 3

ROSE Service Due to their variable profile structure, ROSE operating and display enclosures are flexible in terms of height and width. A wide selection of different profile depths offers the required space for your installations. ROSE suspension systems made of aluminium profile offer the same flexibility. They are available in both standard and customised lengths. Your benefit: we provide you with your customized solution starting at 1 item - quick, cost effective and reliable. You decide what we can do for you! We offer you all the options – from individual components, to completely...

Open the catalog to page 3
OPERATING AND DISPLAY ENCLOSURES - 4

Content Page General technical informations SL 3000 Universal control enclosure system for automation technology ComTronic Aluminium profile compact Commander Commander KSSC Stainless steel control enclosure Commander 410 Stainless steel control enclosure Climatic systems for Commander Suspension system with free accessible cable channel for low loads Aluminium suspension system for low and middle loads Commander 1F Small control enclosure system in aluminium with front frame for front panels and keypads Heat management Commander 1 Small control enclosure system made of diecast aluminium...

Open the catalog to page 4
OPERATING AND DISPLAY ENCLOSURES - 5

GTH 48 easy / GTH 60 easy Stainless steel round tube system with system components Pilot 50 Polyamide/PVC hand held en- 187 closure for MCR- and automation engineering Pilot 10/20/30 Hand held enclosure for MCR-and automation engineering Pilot 110-150 Polyamide hand held enclosure 194 for automation and control engineering Electro-mechanical components

Open the catalog to page 5
OPERATING AND DISPLAY ENCLOSURES - 6

Enclosure selection criteria Enclosures are generally required to protect the installed equipment from external hazards. These hazards can be varied in nature and are of decisive significance when determining the criteria for the choice of an enclosure. Essential for appraising whether an enclosure meets safety requirements is a precise definition of the hazards expected at an installation location. The most important conditions to consider are the following: 1. Protection against contact and penetration of foreign bodies 2. Protection against water penetration 3. Protection against...

Open the catalog to page 6
OPERATING AND DISPLAY ENCLOSURES - 7

Chemical resistance enclosure materials Chemicals Aluminium Stainless Brake fluid / / Diesel ooil / / Caustic potash solution / + Mineral oils / / Motor oils / / Sodium chloride • • Water (dest. water, / + river-, mains-, sea water) Tartaric acid / / Zinc sulfate • / Polycarbonate Polyester Polystyrene Polyamide The investigations, unless stated otherwise, were carried out at room temperature. Resistances can vary when two different materials come into contact with one another. We cannot therefore accept liability for this data. Explanation of symbols + resistant to all concentrations %...

Open the catalog to page 7
OPERATING AND DISPLAY ENCLOSURES - 8

Chemical resistance enclosure seals and accessories Chemicals Chloroprene EPDM Brake fluid • - Calcium chloride / / Chloral benzene - - Caustic potash solution + / Methylene chloride - / Mineral oils • • Motor oils • • Sodium carbonate / / Carbon toulphide - / Carbon tetrachloride Toluene Trichlorethylene NBR Pocane Polyure- PVC Silicone Water (dest. water, river-, + + mains-, sea water) Tartaric acid + + The investigations, unless stated otherwise, were carried out at room temperature. Resistances can vary when two different materials come into contact with one another. We cannot therefore...

Open the catalog to page 8
OPERATING AND DISPLAY ENCLOSURES - 9

In electronic engineering, enclosures are required to fulfil two tasks: - to protect equipment against external mechanical hazards and radio interference - to protect the environment against mechanical and electrical hazards or radio interference caused by equipment Electromagnetic compatibility (EMC) is becoming an increasingly important factor in the choice of enclosures due to sustained advances in the development of electronic components and increased density of components on circuit boards - this being connected with increased emission of electromagnetic radio interference into the...

Open the catalog to page 9
OPERATING AND DISPLAY ENCLOSURES - 10

Included in delivery Complete enclosure system incl. corners, seals, fixing elements, rear panel or door, front panel fixing set. + Modern enclosure system for control and display systems + Flexible size variability in height and width with 6 enclosure profiles + Easy mounting of door hinge + Integrated handle system Material Profile: DIN EN 573 EN AW-AlMgSi Cast corner: DIN EN AC-AlSi 12 Cu 1 (Fe) Painting Powder coating or natural anodized Colour Profile: optional RAL 7035 or natural anodized, Corner element: optional RAL 7035, light grey or RAL 9007, grey aluminium special colour on...

Open the catalog to page 10
OPERATING AND DISPLAY ENCLOSURES - 11

SL 4000 Profile connecting Executions fixed Possible combinations Profile single Combinations with hinge Combinations fixed Profile 1 (Mounting depth = 80 mm) P 1 + 4 (Mounting depth = 220 mm) door front Profile 2 (Mounting depth = 130 mm) P 2 + 4 (Mounting depth = 270 mm) door front Profile 3 (Mounting depth = 190 mm) P 5 + 6 (Mounting depth = 135 mm) door front Profile 5 (Mounting depth = 55 mm) P 1 + 6 (Mounting depth = 160 mm) door front P 2 + 6 (Mounting depth = 210 mm) door rear P 5 + 4 (Mounting depth = 195 mm) door front P 3 + 6 (Mounting depth = 270 mm) door rear – on request Front...

Open the catalog to page 11
OPERATING AND DISPLAY ENCLOSURES - 12

Overview profile depth Basic profile Profile 5 Handle profile Side C/D External dimensions 65/70 mm Mounting depth 55 mm Profile 5 Body profile Side A/B External dimensions 65/70 mm Mounting depth 55 mm Profile 1 Handle profile 90 Side C/D 6 External dimensions 90/95 mm Mounting depth 80 mm Profile 1 Body profile 90 Side A/B External dimensions 90/95 mm Mounting depth 80 mm Profile 2 Handle profile 140 Side C/D External dimensions 140/145 mm Mounting depth 130 mm Profile 2 Body profile 140 Side A/B External dimensions 140/145 mm Mounting depth 130 mm