1. Catalogs
  2. Rongtech Industry (Shanghai) Inc.,
  3. RCT100LTA leakage current sensor

RCT100LTA leakage current sensor

RCT100LTA leakage current sensor

RCT100LTA leakage current sensor

Product catalog summary
Introduction
The RCT100LTA series current transducer by Rongtech Industry (Shanghai) Inc. utilizes electromagnetic induction to provide accurate electronic measurement of AC currents with high insulation between primary and secondary circuits.
Electrical Specifications
  • Rated Current (Ipn AC): Ranges from 1.0A to 100A depending on the model.
  • Measuring Range (Ip AC): Ranges from 2.0A to 200A.
  • Turns Ratio (Np/Ns): Varies from 1:200 to 1:2000.
  • Rated Output (Io DC): 4 to 20 mA with ±1.0% accuracy.
  • Supply Voltage: +24V ±5%.
  • Power Consumption: ≤20 + Ip x (Np/Ns) mA.
  • Zero Current: 4 ±0.1 mA.
  • Zero Drift: ≤±0.05 mA/°C from -40 to 85°C.
  • Linearity: ≤0.5% Full Scale.
  • Response Time: ≤200 ms.
  • Frequency Range: 40 to 1000 Hz.
  • Galvanic Isolation: 2.5 KV at 50Hz for 1 minute.
Standards
  • UL94-V0
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000
Applications
  • Variable speed drives
  • Welding machines
  • Battery supplied applications
  • Uninterruptible Power Supplies (UPS)
  • Electrochemical applications
General Data
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -40 to +125°C
  • Mass: Approximately 90g
Mechanical Dimensions
Dimensions are provided in millimeters with a general tolerance of ±1mm.
Directions for Use
  • Ensure correct wiring to avoid damage to the transmitter.
  • Output amplitude can be adjusted as needed.
  • Custom designs are available for different rated input and output currents.
Characteristics Chart
Includes effects of impulse noise and connection pin details.
See more

Catalog excerpts

RCT100LTA leakage current sensor-1

RCT100LTA series current transducer is applied the principle of electromagnetic induction, developed a new type of current transmitter, between primary and secondary high insulation. It provides accurate electronic measurement AC currents.

 Open the catalog to page 1
RCT100LTA leakage current sensor-2

Remarks: 1. All dimensions are in mm. 2. General tolerance ±1mm. 1.When the current will be measured goes through a transmitter, the voltage will be measured at the output end. (Note: The false wiring may result in the damage of the transmitter). 2.Customs can adjust output amplitude of the transmitter by needs. 3.Custom design in the different rated input current and the output current available . || Characteristics chart || Effects of impulse noise

 Open the catalog to page 2

All Rongtech Industry (Shanghai) Inc., catalogs and technical brochures

  1. RM110N06PK

    5  Pages

  2. RM110N06PA

    5  Pages

  3. RM75N08PA

    5  Pages

  4. RM70N06PA

    5  Pages

  5. RM60N10PA

    5  Pages

  6. RM50N06PA

    5  Pages

  7. RM45N06PA

    5  Pages

  8. RM40N10PK

    5  Pages

  9. RM40N10PA

    5  Pages

  10. RM30N20PK

    5  Pages

  11. RM20N10PA

    5  Pages

  12. RVS47N60PN

    11  Pages

  13. RTU75HF120FA1

    7  Pages

  14. RTU50HF120FA1

    7  Pages

  15. RTU40HF120FA1

    7  Pages

  16. RTK600SG120B

    7  Pages

  17. RTK400SG120B

    7  Pages

  18. RTK300HF120B

    7  Pages

  19. RTK200HF120B

    7  Pages

  20. RFR60F30APN

    3  Pages

  21. RFR30F60PN

    3  Pages

  22. RFR30F40PN

    3  Pages

  23. RFM200CC4A2D

    3  Pages

  24. RTO3000HT

    2  Pages

  25. RTC100LTA

    2  Pages

  26. RTC200P3

    2  Pages

  27. RTC50LA2

    2  Pages

  28. RTC25DT52

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.