1. Catalogs
  2. ROLAND ELECTRONIC
  3. E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING

E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING
1 /4Pages

E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING

E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING
1 /4Pages

Catalog excerpts

E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING-1

SINGLE SIDE SYSTEM, CONTACTING • Double sheet control of ferrous materials • No force after measurement • Exchangeable sensors for double sheet control from 0.1 to 12 mm (.004 to 0.472 in.) sheet thickness • Optional version 4P allows the connection of up to 4 sensors • Programmable for 255 different sheet thicknesses • Monitoring of over gauge and under gauge limits, • Monitoring of operating voltage and measuring time • Opto coupled 9 respectively 11-Bit PLC input interface Selectable interfaces: - opto coupled RS232 interface - all common fieldbus technologies

 Open the catalog to page 1
E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING-2

E20 DOUBLE SHEET Description: When sheets are fed automatically, two or more sheets may be fed inadvertently into a processing machine. This can damage tools, cause halt in production or result in expensive repairs. The double sheet detector E20 can reliably prevent this from occuring. In addition to the connection of one sensor an option is available to connect four sensors of the same type (E20-4P). The system can also be used for Hidden Parts Detection. The sensor switching is controlled either sequentially by the PLC or automatically in the new sequencer mode. This function eliminates the...

 Open the catalog to page 2
E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING-3

SINGLE SIDE SYSTEM, CONTACTING (only Fieldbus nur Feldbus) Measurement time: The table below shows the reaction time of the system when detecting Double Sheet with the maximum sheet thickness applicable to each sensor and a selected upper switching limit of 120%. The times for 2, 3 and 4 sensors apply to the sequenzer mode. Sensor Air gap behaviour: The new Double Sheet Detector E20 has a much improved air gap tolerance especially in conjunction with the new sensor P42AGS. There are two types of air gaps in case of double sheet control. First there is the air gap between sensor and sheet surface...

 Open the catalog to page 3
E20 DOUBLE SHEET SINGLE SIDE SYSTEM, CONTACTING-4

Revision 1.6, February 2024 - Subject to technical modification and error ROLAND ELECTRONIC GmbH 75210 Keltem / Germany fax: +49 7236 9392-33 www.roland-electronic.com

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.