Overview: The COSASCO BIO-PROBE Model 6205 is designed for collecting bacterial samples in oil and gas systems, including refineries and pipelines. It is particularly focused on sessile bacteria, which are crucial for corrosion control.

Features:
  • Complies with NACE MR0175 and MR0103 standards.
  • Constructed from 316 Stainless Steel.
  • Includes five sample elements for analysis.

Functionality: The bio-probe collects samples of bacteria, distinguishing between sessile and planktonic forms. Sessile bacteria are of primary concern due to their impact on corrosion.

Sample Collection: The probe has five sample elements, each with a 1cm2 frontal area. Elements are replaced successively to allow for extended exposure while enabling frequent sampling.

Installation and Sizing: Bio-probes are used in 2" systems and are attached via a left-handed thread. Sizing formulas are provided for different monitoring positions (Top, Middle, Bottom of the Line).

Sizing Formulas:
  • Top of the Line: (A + Pw + Wg) - 2 ½”
  • Middle of the Line: (A + 1/2Pd + Wg) - 2 ½”
  • Bottom of the Line: (A + Pd + Wg) - (2 ¾” + Pw)
Where A is the length of the access fitting body, Pw is the pipe wall thickness, Pd is the pipe diameter, and Wg is the weld gap.

Ordering Information: The bio-probe is available in fixed, adjustable, and non-welded versions. Lengths range from 3.00” to 36.00”, with adjustable types available in 0.25” increments.

Accessories: Available accessories include element sets, set screws, and mounting screws.

Disclaimer: The document provides information for reference only and does not constitute a warranty or guarantee. Specifications may change without notice.
See more

Catalog excerpts

BIO-PROBE-1

Features  Meets NACE MR0175 and MR0103  Five Sample Elements for Analysis  Material — 316 S.S. The bio‐probe is used to collect samples of bacteria in Oil and gas systems, including refineries, offshore platforms, pipelines, etc. Bacteria may be present in a system as either sessile (attached to the metal surface), or planktonic (present in the process fluid). There can be considerable differences between the types of bacteria present in either of these two forms. From a corrosion perspective, the sessile bacteria are the ones that are of primary importance since these are the ones that affect the corrosion, and the ones that must be controlled with chemical treatment. For this reason fluid samples for testing of bacteria only test for planktonic bacteria and may be of no relevance at all to corrosion. The bio‐probe has five sample elements, each with an exposed frontal area of 1cm2. Each time a sample is required for analysis a successive element is removed and replaced with a new one, leaving the other four in place. With this successive change of elements, a longer exposure is obtained for each element, but still permits a relatively frequent sample to be taken for analysis. For example, a sample may be removed every two weeks, but each element will have a 10 week exposure to the process fluid. Cosasco Bio‐Probes for the 2" system are used to suspend sample elements in the area to be monitored. Attached to the bottom of the solid plug by means of a left handed thread, the bio‐probe also serves as a primary packing retainer. Formulas for sizing the Bio‐ Probes are shown to the right. Formulas for sizing the Bio‐probes are shown. All Bio‐probes under 3.25” length are made from one piece in a non‐welded construction. Non‐welded Bio‐probes 3.25” or above are available. After selecting the access fitting with a solid plug, and knowing pipe or pressure vessel size, determine the position where the sample elements will be located. Use the formulas shown to calculate bio‐ probe length. If calculated length is not an even .25" increment, select next shortest to nearest .25". Bio‐Probe Sizing: Fixed Top of the Line Monitoring Bio‐probe positions the effective length of sample elements into pipe vessel. (A + Pw + Wg) — 2 ½” Middle of the Line Monitoring Bio‐probe positions ½ of the sample elements on either side of pipe centerline. (A

 Open the catalog to page 1
BIO-PROBE-2

Bio-probes shown Top, Middle, and Bottom of the Line

 Open the catalog to page 2
BIO-PROBE-3

Ordering Information Note: For flush devices which are protruding into the line that may experience high velocity process conditions it is recommended that Wake Frequency Calculations be performed – please contact a Cosasco representative for further details. Bio‐Probe Assembly Fixed Bio‐Probe Assembly Adjustable (4.50" min ‐ 6.00" max) Bio‐Probe Assembly Non‐welded (minimum order length 3.25 inches) Code Order Length LL.LL Order Length 3.00” – 36.00”, For adjustable type enter ADJS (.25 increments) Code Element Alloy* XXXXXX K03005 6205 3.00 K03005 ...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.