video corpo

R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications
12Pages

{{requestButtons}}

Catalog excerpts

R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 1

Test & Measurement R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications

Open the catalog to page 1
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 2

Rohde & Schwarz R&S CTH100A/R&S CTH200A Radio Test Set

Open the catalog to page 2
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 3

Product data applies under the following conditions: • One hour storage at ambient temperature followed by 10 minutes warm-up operation • Specified environmental conditions met • Recommended calibration interval adhered to • All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <, < >, >, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the...

Open the catalog to page 3
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 4

Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean...

Open the catalog to page 4
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 5

Specifications Receiver test mode Transmit signal Frequency range Channel spacing RF output level RF output level uncertainty RF modulation R&S CTH100A ® R&S CTH200A 5 MHz channel spacing CW or FM or voice reporting ® (R&S CTH200A only) FM composite signal FM composite signal uncertainty FM deviation, after performing transmitter test Transmitter test mode Power measurement Frequency range Power level range Absolute maximum input power forward power or reverse power, CW or FM signals (constant envelope) 30 MHz to 512 MHz 0.1 W to 50 W 100 W 50 W 0.8 dB at both connectors, < 200 MHz at both...

Open the catalog to page 5
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 6

Frequency measurement Frequency range Frequency measurement uncertainty Frequency counter resolution Over-the-air (OTA) measurement ® (R&S CTH200A only) Dynamic range Frequency range 30 MHz to 512 MHz 2 kHz 100 Hz power level frequency counter bargraph numeric display 60 dB 30 MHz to 512 MHz Cable fault finder (R&S®CTH200A only) Cable fault finder Nominal cable impedance Velocity factor (VF) Measurement range Measurement resolution and uncertainty settable 3 ranges length < 120 m length < 240 m length < 480 m Minimal reflection of detectable fault Rohde & Schwarz R&S CTH100A/R&S CTH200A...

Open the catalog to page 6
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 7

General data RF connectors ANT RADIO Environmental conditions Temperature impedance impedance operating temperature range storage temperature range –20 °C to +50 °C –55 °C to +85 °C +40 °C/95 % rel. humidity, steady state, in line with EN 60068-2-78 up to 4600 m drip-proof 1 in line with MIL-PRF-28800F in line with MIL-STD-810F method 510.4, proc. II (blowing sand) in line with MIL-STD-810F, 1 method 508.5 1 in line with MIL-PRF-28800F 1 in line with MIL-PRF-28800F Damp heat Maximum altitude Water resistance storage, operating Sand and dust resistance Fungus resistance Salt atmosphere Solar...

Open the catalog to page 7
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 8

Mechanical resistance Vibration random Shock Power rating Rated voltage battery operated Battery current draw off on, depending on active measurement mode low battery warning 5 Hz to 150 Hz, 0.15 mm amplitude const., 55 Hz to 150 Hz, 0.5 g const., in line with IEC 60068-2-6 10 Hz to 500 Hz, 2 in line with MIL-PRF-28800F 30 g shock spectrum, 2 in line with MIL-PRF-28800F 3 batteries, non-rechargeable or rechargeable, DC 4.5 V (3 × IEC LR6/AA) < 0.5 mA (meas.) 25 mA to 105 mA (meas.) approx. 15 minutes before switchoff The R&S®CTH is designed to be routinely used in rugged operational...

Open the catalog to page 8
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 9

Product conformity Electromagnetic compatibility Electrical safety International safety approvals CSA – Canadian Standards Association VDE – Association for Electrical, Electronic and Information Technologies Korea Certification (KC) mark in line with EN 61326-1 (industrial environment), EN 61326-2-1, EN 55011 (class B) in line with EN 61010-1 in line with UL 61010-1 (second edition), CAN C22.2 No. 61010.1-04 CCSAUS mark: certificate number: 2355532 GS mark: certificate number: 40031889 registration number: KCC-REM-RnS-CTH-2011-01-0 2 × 16 characters adjustable in 5 levels from max. to off...

Open the catalog to page 9
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 10

Ordering information Designation Radio Test Set, with operating manual (quick start guide) Radio Test Set with OTA and Cable Fault Finder, with operating manual (quick start guide) Hardcase, for radio test set and accessories Accessories 50 W Load, BNC Adapters and Cables Rohde & Schwarz R&S CTH100A/R&S CTH200A Radio Test

Open the catalog to page 10
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 11

Service options Extended Warranty, one year Extended Warranty, two years Extended Warranty, three years Extended Warranty, four years Extended Warranty with Calibration Coverage, one year Extended Warranty with Calibration Coverage, two years Extended Warranty with Calibration Coverage, three years Extended Warranty with Calibration Coverage, four years Please contact your local Rohde & Schwarz sales office. Extended warranty with a term of one to four years (WE1 to WE4) 3 Repairs carried out during the contract term are free of charge . Necessary calibration and adjustments carried out...

Open the catalog to page 11
R&S®CTH100A/ R&S®CTH200A Radio Test Set Specifications - 12

Service you can rely on J Worldwide and personalized and flexible J Uncompromising quality J Long-term dependability Environmental commitment ❙❙ Energy-efficient products ❙❙ Continuous improvement in environmental sustainability ❙❙ ISO 14001-certified environmental management system Certified Quality System Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Certified Environmental System Certified Quality System Regional contact ❙❙ Europe, Africa, Middle East | +49 89 4129 12345 customersupport@rohde-schwarz.com ❙❙ North America | 1 888 TEST RSA (1 888 837 87 72)...