1. Catalogs
  2. Rohde Schwarz
  3. R&S®CMA180 Radio Test Set Specifications

R&S®CMA180 Radio Test Set Specifications

R&S®CMA180 Radio Test Set Specifications
1 / 28 PagesView full catalog

R&S®CMA180 Radio Test Set Specifications

Product catalog summary
Introduction
The R&S®CMA180 radio test set is a compact and versatile device for testing analog radios, equipped with an RF generator, RF analyzer, AF generator, and AF analyzer. It supports digital radio testing and is suitable for development, production, and service applications.
General Technical Specifications
  • RF Generator: Operates from 0.1 MHz to 3000 MHz with 1 Hz resolution. Output levels vary by frequency and configuration.
  • Modulation: Supports amplitude, frequency, phase, SSB, and FM stereo modulation with internal and optional arbitrary waveform generators.
  • RF Analyzer: Includes power and frequency meters, modulation deviation measurements, and an AF FFT analyzer.
  • Spectrum Measurements: Features FFT spectrum analyzer and options for ACP/OBW measurements.
  • Audio Features: AF generator and analyzer support sine-wave generation and composite AF signals.
  • Timebase: Options for TCXO and OCXO timebases.
Accessories
Includes power supply, battery compartment, Li-ion battery and charger, and AF impedance matching unit.
Power Levels and Frequency Ranges
The device operates from 0.1 MHz to 3000 MHz, supporting CW and PEP with specific power levels for different bands.
Output Level Uncertainty
Varies with temperature and frequency, with less than 1.2 dB uncertainty from +20 °C to +35 °C for frequencies between 0.1 MHz and 1 MHz.
Modulation Capabilities
Supports AM, FM, PM, and SSB with internal and external modulation sources.
Protection Mechanisms
Includes RF power overload protection and shutdown mechanisms for thermal or voltage overloads.
Harmonics and Spurious Responses
Details attenuation of harmonics and nonharmonic signals.
Phase Noise and Residual Modulation
Specifications for phase noise and residual FM, PM, and AM.
Additional Features
Includes power and frequency meters, multitone, and noise generation capabilities.
Amplitude Modulation (AM)
Modes include RMS, RMS·√2, +PK, –PK, ±PK/2 with a range of 0% to 100% and less than 1% uncertainty.
Phase Modulation (PM)
Similar modes to AM with a range of 0 rad to 10 rad.
Single Sideband (SSB) Modulation
Covers SSB-USB and SSB-LSB modes with a frequency range of 100 Hz to 10.5 kHz.
Audio Analysis
AF FFT analyzer with a frequency range from DC to 21 kHz.
Spectrum Measurements
FFT spectrum analyzer for RF signals from 0.1 MHz to 3000 MHz.
RF Swept Spectrum Analyzer
Frequency range from 100 kHz to 3000 MHz with various settings.
AF Generator and Analyzer
Frequency range of 20 Hz to 21 kHz with specific level ranges.
Digital Interface
SPDIF IN/OUT connectors and sampling rate for audio analysis.
Timebase
Details on TCXO and OCXO options.
General Data
Includes RF and AF connectors, remote control interfaces, and environmental conditions.
Power Supply
Specifications for AC and DC power supplies.
Mechanical and Environmental Specifications
Dimensions, weight, calibration interval, and environmental conditions.
Accessories
Information on external power supply and compatibility options.
Product Overview
Complies with international standards for electromagnetic compatibility and electrical safety.
Specifications
Device dimensions, weight, and operating temperature range.
Battery and Charger
Li-ion battery set with nominal operating and charge times.
Audio Features
AF impedance matching unit for audio systems.
Environmental and Mechanical Resistance
Designed to withstand harsh conditions per MIL-STD-810E standards.
Ordering Information
Options and accessories for enhanced functionality.
Service and Warranty
Extended warranty options and global support.
Company Information
Rohde & Schwarz's commitment to sustainability and quality management.
See more

Catalog excerpts

R&S®CMA180 Radio Test Set Specifications-1

Test & Measurement R&S®CMA180 Radio Test Set Specifications

 Open the catalog to page 1
R&S®CMA180 Radio Test Set Specifications-2

Rohde & Schwarz R&S CMA180 Radio Test Se

 Open the catalog to page 2
R&S®CMA180 Radio Test Set Specifications-3

Rohde & Schwarz R&S CMA180 Radio

 Open the catalog to page 3
R&S®CMA180 Radio Test Set Specifications-4

Definitions General Product data applies under the following conditions: • • • • Three hours storage at ambient temperature followed by 15 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or...

 Open the catalog to page 4
R&S®CMA180 Radio Test Set Specifications-5

The R&S CMA180 radio test set is a compact tester for analog radios. It is equipped with a high-performance RF generator, RF analyzer, AF generator and AF analyzer and features advanced interfaces. Its future-ready hardware concept also permits testing of digital radios. An arbitrary waveform generator (ARB) allows the generation of complex RF signals. Designed for high performance, ® usability and portability, the R&S CMA180 is the right choice for development, production and service applications. Rohde & Schwarz R&S CMA180 Radio Test Set

 Open the catalog to page 5
R&S®CMA180 Radio Test Set Specifications-6

General technical specifications RF generator Frequency range Frequency resolution Frequency uncertainty 0.1 MHz to 3000 MHz 1 Hz same as timebase + frequency resolution Output level range RF COM with high-power attenuator RF COM without high-power attenuator Output level uncertainty in temperature range from +20 °C to +35 °C, no overranging output level > –120 dBm 0.1 MHz to 1 MHz 1 MHz to 2000 MHz 2000 MHz to 2700 MHz 2700 MHz to 3000 MHz output level > –112 dBm 0.1 MHz to 1 MHz 1 MHz to 2000 MHz 2000 MHz to 2700 MHz 2700 MHz to 3000 MHz 0.1 MHz to 30 MHz continuous wave (CW) peak envelope...

 Open the catalog to page 6
R&S®CMA180 Radio Test Set Specifications-7

Output level uncertainty RF COM Output level linearity with fixed RF output attenuator setting (digital gain) RF COM Output level resolution Output level repeatability Output level setting range RF COM with high-power attenuator RF COM without high-power attenuator RF OUT RF power overload protection RF COM with high-power attenuator ("RF COM connector attenuation" in setup menu) RF COM without high-power attenuator ("RF COM connector attenuation" in setup menu) RF IN in temperature range from 0 °C to 1 +50 °C , no overranging output level > –120 dBm 0.1 MHz to 1 MHz 1 MHz to 2000 MHz 2000 MHz...

 Open the catalog to page 7
R&S®CMA180 Radio Test Set Specifications-8

Version 04.00, May 2015 Attenuation of second harmonics RF COM with high-power attenuator RF COM without high-power attenuator RF OUT Attenuation of third harmonics RF COM with high-power attenuator RF COM without high-power attenuator RF OUT Attenuation of nonharmonics RF COM, RF OUT, with/without high-power attenuator Nonharmonics, absolute RF COM with high-power attenuator Phase noise harmonics of 24.576 MHz and 25 MHz, except 175 MHz, 225 MHz, 275 MHz, 325 MHz, 375 MHz 175 MHz, 225 MHz, 275 MHz, 325 MHz, 375 MHz harmonics of 800 MHz 920.3125 MHz and 1840.625 MHz 2760.9375 MHz single sideband,...

 Open the catalog to page 8
R&S®CMA180 Radio Test Set Specifications-9

Modulation Modulation Amplitude modulation Source Modulation frequency Modulation distortion range resolution uncertainty, internal source uncertainty, external source range resolution CCITT-weighted internal modulation source, external AF1 IN, AF2 IN, external SPDIF IN 0 % to 100 % 0.1 % <1% <3% 0 Hz to 21 kHz 0.1 Hz <1% range resolution uncertainty, internal source uncertainty, external source range, internal modulation generator CCITT-weighted internal modulation source, external AF1 IN, AF2 IN, external SPDIF IN 0 Hz to 100 kHz 1 Hz <1% <3% 0 Hz to 21 kHz <1% range resolution uncertainty,...

 Open the catalog to page 9
R&S®CMA180 Radio Test Set Specifications-10

Version 04.00, May 2015 Multitone frequency range Noise 1 to 20 selectable tones with individual frequencies and levels 0 Hz to 21 kHz signal composite with flat frequency response 0 Hz to 21 kHz Modulation source: arbitrary waveform generator (ARB) (R&S®CMA-B110B option) Memory size Word length Sample length Sample rate Maximum possible RF bandwidth I Q marker with 4-bit marker minimum maximum depending on arbitrary waveform file Trigger Trigger sources Delay Repetition external TRIG IN 0 s to 100 s single, continuous Interferer Interferer Delta frequency range Delta level range Modulation RF...

 Open the catalog to page 10
R&S®CMA180 Radio Test Set Specifications-11

Version 04.00, May 2015 Harmonic response RF COM Spurious response Inherent spurious response Phase noise Dynamic range RF COM with high-power attenuator RF COM without high-power attenuator second harmonic fin = 1 MHz to 1000 MHz, fselected = 2 MHz to 2000 MHz, input power near expected nominal power setting fin = 1000 MHz to 1500 MHz, fselected = 2000 MHz to 3000 MHz, input power near expected nominal power setting third harmonic fin = 1 MHz to 666.7 MHz, fselected = 3 MHz to 2000 MHz, input power near expected nominal power setting fin = 666.7 MHz to 1000 MHz, fselected = 2000 MHz to 3000...

 Open the catalog to page 11
R&S®CMA180 Radio Test Set Specifications-12

Power meter TX test, expert test Frequency range Frequency resolution Measurement modes Resolution bandwidths Expected nominal power setting range Measurement control Level range RF COM with high-power attenuator RF COM without high-power attenuator measurement timeout repetition statistic measurement length step length 0.1 MHz to 1 MHz continuous wave (CW) peak envelope power (PEP) 1 MHz to 30 MHz continuous wave (CW) peak envelope power (PEP) 30 MHz to 2000 MHz continuous wave (CW) peak envelope power (PEP) 2000 MHz to 3000 MHz continuous wave (CW) peak envelope power (PEP) 0.1 MHz to 1 MHz...

 Open the catalog to page 12
R&S®CMA180 Radio Test Set Specifications-13

Version 04.00, May 2015 Level uncertainty RF COM Level uncertainty RF COM with high-power attenuator Level resolution Level repeatability Level linearity, with fixed expected nominal power setting RF COM in temperature range from +20 °C to +35 °C, no overranging 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000 MHz to 3000 MHz 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000 MHz to 3000 MHz in temperature range from 0 °C to 3 +50 °C , no overranging 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000 MHz to 3000 MHz 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000...

 Open the catalog to page 13

Archived catalogs

  1. R&S®EVSF1000

    12  Pages

  2. R&S®UMS175

    10  Pages

  3. R&S®AVHE100

    24  Pages

  4. HM8030

    2  Pages

  5. SMU200A Flyer

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.