The document provides technical data and usage instructions for the FLAWFINDER Dye Penetrant, a non-destructive testing (NDT) crack detection spray. It is designed for visual detection of cracks or flaws in materials such as welded joints, castings, and forgings.

Product Features
  • Highly visible red dye for easy detection.
  • Can be used under natural or electric light.
  • Easily removable by solvent or water washing.
  • Convenient and easy to use.

Directions for Use
  1. Shake the aerosol well before use and apply from a distance of 15-20 cm.
  2. Clean the test area with FLAWFINDER Cleaner Spray and ensure it is dry and free of contaminants.
  3. Apply FLAWFINDER Dye Penetrant Spray and allow a minimum contact time of 10 minutes.
  4. Remove excess penetrant with a tissue or lint-free cloth wetted with FLAWFINDER Cleaner.
  5. Apply a thin film of FLAWFINDER Developer Spray and leave for at least 10 minutes.
  6. Examine the area under natural or electric light for signs of flaws or cracks.

Technical Specifications
  • Propellant: Carbon dioxide
  • Solvent: Isoparaffinic hydrocarbon
  • Appearance: Deep red

Storage Instructions
  • Store below 50°C and out of direct sunlight.

Packaging
  • Pack size: 300ml
  • Part Code: 63151

Additional Notes
  • Do not spray the cleaner directly onto the surface to avoid flushing out the penetrant from flaws.
  • If results are inconclusive, repeat the process with greater care.

Date of Document
January 2009
See more

Catalog excerpts

TDS-1

Technical Data FLAWFINDER DYE PENETRANT NDT Crack Detection Spray FLAWFINDER Non-destructive inspection system is designed to provide a fast reliable method for visual detection of cracks or flaws which would not normally be visible to the naked eye. Ideal for the inspection of welded joints, castings, forgings etc... FLAWFINDER DYE PENETRANT is an aerosol applied red dye which is designed to penetrate into the finest cracks and flaws to facilitate detection when used in conjunction with FLAWFINDER DEVELOPER and FLAWFINDER CLEANER Sprays. • Highly visible red dye. • Detection can be carried out under natural or electric light. • Easily removed by solvent or water washing. • Convenient and easy to use. • Shake aerosol well before use. • Apply from a distance of 15-20cm. The information in this publication is based on our experience and reports from customers. There are many factors outside our control or knowledge which affect the use and performance of our products, for which reason it is given without responsibility.

 Open the catalog to page 1
TDS-2

Technical Data Application Method 1. Clean the area to be tested with FLAWFINDER CLEANER SPRAY (No.1) and wipe thoroughly with a tissue or a lint-free cloth to ensure the surface is clean, dry and free of contaminants. 2. When the surface is completely dry apply FLAWFINDER DYE PENETRANT SPRAY (No.2) to cover the test area and allow a minimum contact time of 10 mins. Finer definitions may require longer contact time. 3. Once the contact time has elapsed, the excess penetrant should be removed from the surface with a tissue or lint-free cloth wetted with FLAWFINDER CLEANER (No.1). 4. Apply a THIN...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.