CHROMA FPA
2Pages

{{requestButtons}}

Catalog excerpts

CHROMA FPA - 1

Teledyne Imaging Sensors CHROMA™ Visible-Infrared Focal Plane Array Teledyne’s CHROMA™ configurable Hyperspectral Readout for Multiple Applications) is the most advanced focal plane array (FPA) developed for visible-infrared spectral imaging applications. Combined with Teledyne’s high performance substrate-removed HgCdTe detector technology, the CHROMA™ performance is unmatched by any other sensor. Array formats: 480 spectral channels (rows) with spatial dimension in multiples of 160 columns (e.g. 320×480, 640×480, 1280×480, 1600×480 pixels) Pixel pitch: 30×30 μm FPA architecture is a CMOS readout flip-chip hybridized to a detector. The readout circuit can be mated to substrate-removed HgCdTe for simultaneous visible-infrared detection or Teledyne’s HyViSI™ silicon PIN visible detector. Bandpass coverage: 330-1050 nm, 350-2500 nm, and 380-5500 nm. CHROMA-1280 array in ceramic package Readout integrated circuit characteristics Capacitive transimpedance amplifier (CTIA) in pixel Correlated double sampling (CDS) in pixel for well sizes up to 1M electrons Full well options = 0.7M, 1M or 5M electrons Readout noise = 80, 110 or 600 electrons, corresponding to 0.7M, 1M and 5M electrons full well, respectively Readout mode: Snapshot, integrate-while-read Windowing available in row direction Dynamic range: 9000:1 Frame readout time scales with number of rows read out; row readout time is16.8 μsec; Full-frame rate (480 rows) is 125 Hz, Half-frame rate (240 rows) is 250 Hz Integration time programmable in row time steps Programmable, digital input: biases and clocks generated on-chip Panel-based readout: one analog output per 160 columns; output data rate (each output) is 10 Mpixels/sec April 2012 For more information, please contact Jianmei Pan at jpan@teledyne.com or at +1(805) 373 4291, or Richard Demers at rdemers@teledyne.com or at +1(805) 373 4607 Cleared for Public Release by the DoD's Office of Security Review, Case 12-S-1872

Open the catalog to page 1
CHROMA FPA - 2

CHROMA™ configuration table for infrared and visible arrays Well capacity & Readout Noise Power ROIC No. dissipation dimensions Outputs at 125 Hz [mW] [mm] Array Format Other combinations of array format and well sizes are available in customized versions Array row lengths (number of columns) can be customized to be any multiple of 160 Pixel well sizes can be easily customized in the range from 0.2M electrons to 5M electrons Focal Plane Electronics with 16 bit analog to digital conversion is available AVIRIS hyperspectral data cube over Moffett Field, California For more information, please...

Open the catalog to page 2

All Rockwell Scientific catalogs and technical brochures

  1. HMIR

    2 Pages

  2. CHROMA FPE

    2 Pages

  3. HxRG

    2 Pages

  4. TDSO-050

    5 Pages

Archived catalogs

  1. UAV-Cam V2M

    2 Pages

  2. UAV-Cam V2M

    2 Pages

  3. HAWAII 4RG

    2 Pages

  4. UAV-Cam V59M

    2 Pages