Volume corrector EC 24
8Pages

{{requestButtons}}

Catalog excerpts

Volume corrector EC 24 - 1

SERVING THE GAS INDUSTRY WORLDWIDE Technical Product Information GAS VOLUME CORRECTOR EC 24 G A A S V V OLUM E E C C O R R REC T T O O R R EC 24 > RMG Messtechnik GmbH size="-2">

Open the catalog to page 1
Volume corrector EC 24 - 2

GAS METER ELECTRONIC METER HEADVOLUME CORRECTOR Volumeter TERZ 94 Publication No. 3.174 TEC 24 page 6 TRZ (standard) TRZ 03-TE Publication No. 3.163 TRZ 03-TE/ EC 24 page 5 TRZ (without inlet pipe) TRZ 03-TEL Publication No. 3.164 TRZ03-TEL/ EC 24 page 5 >

Open the catalog to page 2
Volume corrector EC 24 - 3

Data logger Digital interface Read-out and parameterization program The monthly values and meter readings for the volume at measurement and base conditions, pres- sure and temperature are stored for a period of 14 months. A serial RS 485 interface with Modbus protocol is available for exchanging data. Օ Using an easy-to-operate program, measured values and totalizer readings, for example, can be read or the device can be parameterized. Flow display In the case of electronic turbine meters with Wiegand sensors (and HF input pulses), the current ow rate value and the maximum value are...

Open the catalog to page 3
Volume corrector EC 24 - 5

DESIGNTURBINE METERVOLUMETER nominal diameter DN 25 - DN 600DN 50 - DN 600 pressure rating up to PN 100/ANSI 600up to PN 100/ANSI 600 measuring range 10 - 25000 m/ h2,5 - 25000 mӳ/ h > Turbine metertype TRZ 03-TE Electronic turbine metertype TERZ 94 - 0085 - 0085 Ser.-No.Belongs to measuring unitSer.-No. Ser.-No.Belongs to measuring unitSer.-No. Vm 3 Vm/h 3 PbaraTCZuIomAErrorTyp Mode Vm 3 Vm/h 3 PbaraTаCZuIomAErrorTyp Mode Ser.-No.Year Ser.-No.Year Dry gas in standard condition1.01325 bar,0C, = 0Further data press buttons Dry gas instandard condition1.01325 bar,0аC, = 0Further data press...

Open the catalog to page 5
Volume corrector EC 24 - 6

Mechanical gas meters in conjunction with the EC 24 > The EC 24 volume corrector can also be connected con-ventionally to mechanical gas meters: - turbine meters for custody transfer metering, such as the TRZ 03 or TRZ 03-L; - mechanical volumeters, such as the TRZ 03-K; - rotary displacement meters, such as the RMG 132-A or DKZ 04; - any other gas meters with LF pulse transmitters.In the case of RMG gas meters, the easiest way to install the volume corrector is directly on the meter head using a bracket. Installation is even possible farther away from the meter up to a distance of 50 m and...

Open the catalog to page 6
Volume corrector EC 24 - 7

SPECIFICATIONS Explosion protection II2 G EEx ib [ia] IIC T3/ T4 Case cast aluminium case Dimensions (L x W x D) 250 x 120 x 105 mm Weight approx. 1.5 kg Degree of protection IP 65 > Ambient temperature range -20C to +60аC Measuring temperature range -20C to +60аC Resistance thermometer PT 1000, 2-wire connection 0.7 - 2 bar (a)0.8 - 5 bar (a) 2 - 10 bar (a) 4 - 20 bar (a) 8 - 40 bar (a) 14 - 70 bar (a) Pressure ranges Pressure transmitter connection M12 x 1.5 coupling for ERMETO 6L (6mm pipe), an adapter is required for other cross sections Distance of remote totalizer max. 50 m...

Open the catalog to page 7
Volume corrector EC 24 - 8

ENGLANDBryan Donkin RMG Gas Controls Ltd. WGA WĤrme-Gastechnik GmbH Enterprise Drive, HolmewoodChester eld S42 5UZ, EnglandFon +44 (0)1246 50150-1 Fax +44 (0)1246 50150-0 Osterholzstrae 45D-34123 KasselFon +49 (0)561 5007-0 Fax +49 (0)561 5007-207 POLANDGazomet Sp. z o.o. RMG Gaselan Regel + Messtechnik GmbH Julius-Pintsch-Ring 3D-15517 F߼rstenwalde Fon +49 (0)3361 356-60 Fax +49 (0)3361 356-836 ul. Sarnowska 2 63-900 Rawicz, PolenFon +48 (0)65 54624-01 Fax +48 (0)65 54624-08 CANADABryan Donkin RMG Canada Ltd. 50 Clarke Street South, WoodstockOntario N4S 7Y5, Canada Fon +1 519 53-98531 Fax...

Open the catalog to page 8

All RMG catalogs and technical brochures