Overview: The Artos™ is a high-performance magnetic encoder system designed for motion control applications, offering reliable feedback for angle and velocity control loops. It is characterized by high reliability, low latency, high resolution, and robust protection against environmental factors.
Features and Benefits: The system is a true absolute encoder with high accuracy, suitable for dynamic control loops at speeds up to 30,000 rpm. It features IP67 protection, excellent EMC compatibility, and supports SSI and BiSS communication protocols. It is compatible with both solid rings and partial arc scales.
General Information: The encoder provides absolute position data immediately after power-on, with large installation tolerances and a robust design. It uses a magnetic ring/scale with a pseudorandom binary sequence read by proprietary sensor technology, requiring no post-installation calibration.
Magnetic Ring Options: Rings are available in exposed and protected versions, suitable for various environmental conditions, including harsh environments and high-speed applications.
Installation Instructions: The readhead can be installed in three orientations, with proper alignment crucial. M3 fasteners are recommended, and an LED indicates installation status.
Technical Specifications: The system uses a pseudorandom binary sequence for absolute coding, offers up to 23 bits resolution, operates on a 4.75 V to 30 V power supply, and is environmentally sealed to IP67 standards, with an operating temperature range of –20 °C to +85 °C.
Electrical Connections: Utilizes RS422 differential line driver signals and supports various connectors, with proper shielding essential for EMC compliance.
Status Indicator LED: The LED indicates operational status: green for normal, orange for warnings, and red for errors.
Handling and Storage: The system is ESD sensitive, packaged in antistatic bags, and labeled with part and serial numbers.
Troubleshooting and Installation Guidelines: Ensure proper alignment of the readhead and verify power supply, especially for longer cables. Use a magnetic viewer for detecting abnormal patterns.
Communication Interfaces: The BiSS C protocol provides absolute position data with a maximum frequency of 5 MHz, while the SSI protocol requires a clock signal with a maximum frequency of 500 kHz, extendable to 2.5 MHz.
Error and Warning Descriptions: Status bits indicate errors and warnings, such as temperature issues and signal distortion, with specific conditions for clearing errors.
Cable and Connector Specifications: Maximum cable length is 15 meters, with specific tolerances. Various connector types are available, and extension cables must not exceed the total length limit.
Resolution and Part Numbering: Resolutions are specified in counts per revolution and micrometers, with part numbers indicating output type, resolution, cable length, and connector type.
Accessories: Accessories include magnet viewers, extension cables, USB interfaces, installation tools, and fasteners.
Disclaimer and Liability: RLS Merilna tehnika d.o.o. disclaims liability for inaccuracies and specifies that the product is not intended for critical applications without written agreement.
Product Performance: Performance data is based on laboratory conditions and may not reflect other environments. Suitability for specific applications is not guaranteed.
Warranties: No express or implied warranties are provided beyond the seller's terms and conditions.
Document Revisions: Revisions include part numbering amendments on 24th April 2024 and 21st June 2024.
Contact Information: RLS Merilna tehnika d.o.o. is based in Slovenia, with contact details for global support and sales inquiries.
See more

Catalog excerpts

Artos_DRD01_03-1

DATA SHEET DRD01_03 Issue 03, 21st June 2024 Artos™ Rotary and Linear Absolute Magnetic Encoder System TRUE ABSOLUTE SYSTEM ArtosTM is an absolute magnetic encoder system designed for motion control applications as a feedback element for angle and velocity control loops. A highly reliable measurement principle and processing provide low position latency, high resolution and high angular velocity. The robust design protects the readhead and magnetic ring from liquid ingress and high temperatures, so they remain undamaged even in extremely contaminated and hot environments. COMPACT ROBUST DESIGN HIGH SPEED AND RESOLUTION True absolute system SSI and BiSS communication protocols High accuracy and resolution Suitable for highly dynamic control loops Compatible with solid rings and partial arc scales Robust design and great EMC compatibility Wide installation tolerances MACHINE TOOL ASSEMBLY LINES INDUSTRIAL AUTOMATION

 Open the catalog to page 1
Artos_DRD01_03-2

General information ArtosTM provides a true-absolute position information immediately after power-on via the selected communication protocol. The encoder system is extremely reliable due to the large installation tolerances (axial/radial/tangential offsets) and the robust IP67 design of the ring and readhead. The measuring principle is based on a magnetic ring/scale magnetised with the incremental and absolute track with a pseudorandom binary sequence (PRBS) read by RLS proprietary sensor technology. Once installed, the encoder system does not need to be calibrated. To ensure the installation...

 Open the catalog to page 2
Artos_DRD01_03-3

Storage and handling Storage temperature Operating temperature Readhead is ESD sensitive - handle with care. Do not touch electronic circuit, wires or sensor area without proper ESD protection or outside of ESD controlled environment. This encoder system is a high performance measuring instrument and should be handled with the same care as any other precision instrument. The use of industrial tools during installation or contact with strong magnets, such as a magnetic base, is not recommended as there is a risk that parts of the system will be damaged and may not function to specifications as...

 Open the catalog to page 3
Artos_DRD01_03-4

Dimensions drawing DATA SHEET DRD01_03 Dimensions and installation drawings Dimensions and tolerances are in mm. Dimensions without tolerance values are in accordance with ISO 2768-m. Ø5 2.5 14 M3 THRU Dimensions drawing Dimensionsdrawing drawing Dimensions A (5 : 1) 3D models are available at RLS website. A (5A: (5 1) : 1) Installation surfaces General tolerances for linear dimensions according to ISO 2768-m Tolerance class Further information on compatible rings and scales can be found in SARD01 and ASD01, available at RLS Media center. Installation surfaces Installation Insta

 Open the catalog to page 4
Artos_DRD01_03-5

Installation instructions Installation instructions with rings or magnetic scale for partial arc applications The readhead can be installed in 3 different ways - from the left, right or top, as shown in the drawings below. Carefully plan the orientation of the readhead and the ring or magnetic scale. The engraving on the ring and the print on the scale can be used to determine the orientation. We recommend the use of M3 fasteners with washers. For more information, please refer to the Table of recommended fastener tightening torques. After mounting the ring or magnetic scale with the readhead,...

 Open the catalog to page 5
Artos_DRD01_03-6

Technical specifications System specifications Type of absolute measurement Pseudorandom binary sequence (PRBS) absolute code; RLS proprietary sensor technology Reading type <3.5 µm at nominal ride height SAR057 = 25 arcsec SAR081 = 18 arcsec SAR114 = 13 arcsec SAR162 = 9 arcsec SAR229 = 6 arcsec SAR325 = 4 arcsec SAR478 = 3 arcsec Unidirectional repeatability Rings: up to 23 bits binary resolution (depends on the ring size) Magnetic scales: up to ~0.122 μm See Table of available resolutions. Sensor and processing latency Internal loop refresh rate Maximum speed during power up Electrical data...

 Open the catalog to page 6
Artos_DRD01_03-7

Cable Cable type 8 core, PUR high flexible cable, braided shield, pairs not twisted Outer diameter White and brown wires 0.14 mm2, 26 AWG, 0.14 Ω/m Other wires 0.08 mm2, 28 AWG, 0.23 Ω/m Cable: Dynamic 50 min. mm Bending radius Cable bending radius 20 million cycles (expected value) at 50 mm bend radius Maximum cable length Flexible application Cable: min. Bending radius Cable bending radius Fixed laying application Continuously flexible application Fixed laying Continuously flexible Min. R35 Min. R10 Min. R35 Min. R10 Flexible application The cable requires adequate strain relief to ensure its...

 Open the catalog to page 7
Artos_DRD01_03-8

Electrical connections Shield connection The following figure shows the recommended shield termination in order to ensure electromagnetic compatibility. Customer electronics Encoder system 5 to 30 V Serial communication signals GND Outer shield Max cable length = 15 m The encoder housing is galvanically connected to the connector housing. To achieve EMC compliance, the encoder system must be correctly integrated. In particular, attention to shielding arrangements is essential. Serial communication Reserved Shield Wire colour (Flying Leads) DATA+ / SLO+ Bare wire 9-way D-type connector (male type)...

 Open the catalog to page 8
Artos_DRD01_03-9

Status indicator LED Once the ring or magnetic scale has been installed, the readhead can be easily mounted on the machine using the LED setup indicator. The LED indicator shows the internal status of the encoder and is used to facilitate the installation and diagnosis of the encoder system. According to the table Detailed status description, certain errors are latched, resulting in LED indicating error status persistently. To clear latched error statuses, communication with readhead or readhead power cycle is required. Slow flashing of LED indicates that the encoder is receiving power, but communication...

 Open the catalog to page 9
Artos_DRD01_03-10

Troubleshooting If the readhead reports an error during operation due to incorrect decoding of the absolute position on the magnetic ring/scale, this indicates a serious problem. Serious problems include incorrect installation or a damaged magnetic pattern on the ring or scale. To determine the cause of the problem, please proceed as follows: ⦁ Make sure that the part number on the readhead and the ring or scale match the required combination. The valid combination of ring and readhead can be verified with the first 6 letters of the part number. Verify that the installation matches the specificaion...