SYCON 2502
6Pages

{{requestButtons}}

Catalog excerpts

SYCON 2502 - 1

The limit value device SYCON 2502 Safety reliably produced.

Open the catalog to page 1
SYCON 2502 - 2

Definitely the correct and reliable measurin value. Since 2012 ... ... our analyzer SYCON 2501 stands the test in the daily use. Thanks to the feedback and ideas for improvement of a lot of loyal customers, we have refined this successful analyzer and now proudly present our new analyzer generation to you: the SYCON 2502. It can be used …, … where it depends on the precise compliance with individual limit values. With the SYCON 2502, we offer reliable analysis technology according to your requirements. The SYCON 2502 includes a demandcontrolled regeneration triggering and a monitoring of...

Open the catalog to page 2
SYCON 2502 - 3

• Easy installation • Robust and reliable measurement technology • More than 5,000 analyses per reagent bottle Safety reliably produced. 202210I

Open the catalog to page 3
SYCON 2502 - 4

We provide • technically competent contact persons at eye level • modern development with many years of experience in the area of measurement and sensor technology • complete production on site in Hildesheim, from the assembly of the electronics to the final assembly of the devices Our measuring chamber tested according to DIN EN 13443-3 can withstand a pressure of 5 bar for at least 200,000 analyses: check out the video on our website www.rls-wacon.de/messkammer 202210I

Open the catalog to page 4
SYCON 2502 - 5

Overview of performance features: Fully automatic The device detects hardness breakthroughs fully automated depending on the used reagent. Thus, the analysis process is more effective than manual methods and more sustainable than other measuring methods that work only indirectly. Intelligent and accurate The device does not need to be calibrated. External influences on the measurement due to contamination of the measuring chamber, turbidity of the sample and external light effects are recognised by the integrated measurement technology and a two-stage analysis process with zero point...

Open the catalog to page 5
SYCON 2502 - 6

General Specifications Value / Range Supply voltage Power consumption Protection class Ambient temperature Temperature of water sample Humidity 85 … 264 VAC at 47… 440 Hz 25 VA (during operation) IP 43 (with housing IP 54) 5 … 45 °C 5 … 40 °C 20 … 90 % RH non-condensing Technical Data Value / Range Signal input Connection inlet / outlet Wall mounting in closed rooms on wall holder: 274 x 275 x 130 mm (W x L x H) with housing: 330 x 300 x 185 mm (W x L x H) on wall holder: 1,9 kg with housing: 3,7 kg 3 relays 250 VAC / VDC 4 A potential free outputs NC/NO > limit value alert > device error >...

Open the catalog to page 6