VGR-B100-1

Paperless Recorder Descr union

 Open the catalog to page 1
VGR-B100-2

Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! p pera Touch Screen Operatio T atiiio on Usser friendly interface through a 5.7 inch LCD touch scrreen. Most of daily operations are achievedd on the touch screenn. M Basic Display Screens Real-time Trend Display Digital Display ach press of the GRAPH key on the screen switches the present screen the next. (Horrizontal) Historical Trend Disp play play (S (Saved d record files) The REAL key on the real time trend scree screen allows access to the historical data of the currently displayed data and the data from saved file....

 Open the catalog to page 2
VGR-B100-3

Quick start of recording at the press of REC button Recording starts immediately after upon pressing the REC button. The recorded data can be easily copied to the SD card and viewed with Excel or the supplied software. SD Card Slot • An SD card is not supplied with the product and must be supplied by the user. • The recorded data is first stored in the internal Flash memory and then copied into the external SD card when recording is stopped. • The following table is based on 6 analog inputs (binary format only), without saving max/min values, alarm and messages. SD Card Capacity File saving cycle...

 Open the catalog to page 3
VGR-B100-4

Versatile Data Management Function V Coomment function allows the user to enter a comment at any time axis. Data management of plural recorders using the supplied software. Comment Function Comment can be entered at any time axis. Touching g the entered comm ment switches the screen to the time axis of the comment h selected l d comment. T captured screen image can The bee also saved in bitmap format. Real-time Trend Graph p Maximum 8 recorders can be viewed on the same screen via Ethernet. Software (Data Viewer) • Standard software Data management Item • Real-Time Trend Display • Measured Data...

 Open the catalog to page 4
VGR-B100-5

-(Terminal Unit 5)~ Terminal Unit 1 - IL Jl Analog Input 10 to 12 CH terminal Power Supply/Total Alarm/Communication terminal -(Terminal Unit 4)- Relay contact output terminal • Select one from [Analog input 10 to 12ch] [DI/DO] or [Relay contact output]. [Specify when ordering.] ■{Terminal Unit 1)- -(Terminal Unit 2)- ■{Terminal Unit 3~)- Analog Input 1 to 30 CH terminal Analog Input 4 to 6 CH terminal

 Open the catalog to page 5
VGR-B100-6

Input Measurement range/accuracy External memory : Internal memory : Memory Capacity : Main record data : Sub record data : Recording cycle : Data saving cycle : Trend data Other record data Memory remaining capacity display Power supply voltage Number of inputs : 3, 6, 9, 12 points •Isolated between each input) Measurement interval : 100m sec Input signal : DC voltage, DC current (Using external shunt resistor), Thermocouple, RTD Burnout : Available on TC and DC mV range, •ON/OFF selectable (per channel) Influence of external resistance (Thermocouple) : Approx. 0.18^V/Q Influence of input lead...

 Open the catalog to page 6
VGR-B100-7

Panel Cutout External Dimension Remote AI Specifications (Optional) Power supply : 21.6 to 26.4V DC (Rating 24V DC) Insulation resistance : Between terminals and ground : 20MQ or more (at 500V DC) Dielectric strength : 500V AC for one minute between input terminals 500V AC for one minute between input terminals and ground 500V AC for one minute between power terminals and ground Ambient temperature and humidity : 0 to 50°C, 20 to 80%RH Net Weight : Approx 670g Mounting method : DIN rail or screw mounting Compliance with Standards : CE marking : EMC : EN61326-1 • To be released soon Power supply...

 Open the catalog to page 7
VGR-B100-8

Paperless Recorder i System Configuration Ethernet (Modbus/TCP) Standard Accessories : Mounting brackets, Packing for waterproof (Panel packing, O-ring) CD-ROM (Instruction Manual, Software) *1 When 12 channel input type is specified, no digital inputs/outputs nor relay contact outputs are available. *2 Ethernet communication is standard function. Optional AccessoriesDI/DO cable (1m) rShunt resistance for a current input The terminator for RS-485 Model Code : WMSU0303A01 200Q Remote AI (Analog Input) Specifications Standard Accessories : CD-ROM (Instruction Manual) Optional Accessories_ IThe...

 Open the catalog to page 8

All RKC INSTRUMENT INC catalogs and technical brochures

  1. PF900

    8  Pages

  2. MA901

    6  Pages

  3. MA900

    6  Pages

  4. COM-ME-1

    2  Pages

  5. SRX

    8  Pages

  6. SRZ

    12  Pages

  7. SB1

    8  Pages

  8. REX-F9000

    3  Pages

  9. HA930

    6  Pages

  10. GZ400 / GZ900

    12  Pages

  11. FB400 / FB900

    12  Pages

  12. FB100

    8  Pages

  13. SA200

    6  Pages

  14. SA100

    6  Pages

  15. RZ SERIES

    4  Pages

  16. SB1 Series

    8  Pages

  17. RB SERIES

    8  Pages

  18. AG500

    108  Pages

  19. PRODUCT CATALOG

    167  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.