A new set of controllers has been added to the CB Series to provide additional configuration flexibility. These instruments have a third contact that can be configured as an analog retransmission output, a digital contact output for RUN/STOP status or a third alarm and a contact input for SV1/SV2 or RUN/STOP functions. These instruments are designed for heat only operation and are available in either reverse or direct control action. The Heat/Cool output or digital communications are not available on this series. Features Bright, easy-to-read LED displays Digital contact input/output it Analog retransmission output it Three separate alarms ix Dual set points it Advanced self-tuning ix IP66 (65) Waterproof/Dustproof protection Bright, Easy-To-Read LED Displays The CB Series features large, bright LED displays that have been designed to be easy-to-read from greater distances. Analog Retransmission Output (Optional) The third output can be configured as an analog retransmis-sion output. With this function, the process value can be retransmitted as an analog current signal (4-20mA). Three Separate Alarms (Optional) The third output can be configured for a third alarm. Digital Contact Input/ Output (Optional) The contact input can be selected to run either the RUN/STOP or SV1/SV2 functions. The third output can be configured to view the RUN/STOP status. CB Series Feature Comparison <13 Digital contact input RUN STOP " "—-——Series Functions ■—-—
Open the catalog to page 1Temperature Controller Features Heater Break Alarm The heater break alarm (HBA) detects a fault in the heating or cooling circuit and displays actual amperage in the display on the front panel. If the measured value becomes lower than the preset value, the alarm is activated. The HBA function requires a current detector for measuring and monitoring the current load. Self-Tuning Algorithm The CB Series offers a new self-tuning feature that is initiated at start-up and when process parameters or conditions change. In these situations, the controller evaluates whether the preset PID parameters should...
Open the catalog to page 2Specifications Input Control Output Relay output : Voltage pulse output : Current output : Triac trigger output : Temperature Alarm Analog Output Input a) Thermocouple : K, J, R, S, B, E, T, N (JIS/IEC), PLII (NBS) •Influence of external resistance : Approx. 0.2pV/Q •Input break action : Up-scale •Influence of input lead resistance : Approx. 0.01[%/Q] of reading •Maximum 10Q per wire •Input break action : Up-scale c) DC voltage : 0 to 5V, 1 to 5V (0.0 to 100.0% (Default value)) •Input break action : Down scale d) DC current : 0 to 20mA, 4 to 20mA (0.0 to 100.0% (Default value)) •For DC current...
Open the catalog to page 31 Loop break alarm is not available for Heat/Cool PID control type. 2 Heater break alarm can only be assigned to Alarm 2. Heater break alarm is not available for current output. Accessories Current transformer for heater break alarm CTL-6P-N (0 - 30A) Shunt resistor for DC current input KD100-55 Terminal cover
Open the catalog to page 4•Panel cutouts Units : mm