Temperature Controller SA100 General Description The SA100 is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DIN rail. The SA100 has features such as analog retransmission output, advanced self-tuning, alarms, digital communications for networking and digital contact for SV1/SV2 or RUN/STOP functions.. Features Corresponding to Various Applications Two points of output can be used as control, alarm or analog retransmission. The SA100 corresponds to various applications such as temperature controller and overheat protection unit. Simple mounting on DIN Rail Corresponding to various applications Analog retransmission output Digital communications Advanced self-tuning • As a overheat protection unit or alarm unit 1. Overheat protection unit The SA100 can be simply mounted on a DIN rail with DIN rail mounting socket. The maintenance is also simple, as the unit can be removed from socket. • As a temperature controller 1. Temperature alarm controller PV (measured value) SV (set value) display only display only Parameters are displayed on SV display. Analog Retransmission Output (Optional) Rear terminal socket An analog output is available so that the process value can be retransmitted an analog signal to a remote instrument such as a recorder or data-logging equipment.
Open the catalog to page 1Temperature Controller Features Temperature Alarm A: SV A: Alarm Two alarm points can be configured for specific applications. Alarm Type • Temperature Alarm Deviation High, Deviation Low, Deviation High/Low, Band, Process High, Process Low (Hold action can be added to deviation and process type) • Loop Break Alarm The Heat/Cool PID control features heat and cool outputs for use where process-generated heat exists. This allows the input of overlap or deadband settings which contribute to energy savings. An optional digital contact input is available for RUN/STOP and SV1/SV2, alarm interlock release...
Open the catalog to page 2Temperature Controller Specifications Input Setting Range d) Loop break alarm : a) Thermocouple : K, J, E, T, R, S, B, N (JIS/IEC), PLII (NBS) •Influence of external resistance : Approx. 0.2pV/Q •Input break action : Up-scale •Influence of lead resistance : Approx. 0.01[%/Q] of reading • Maximum 10Q per wire •Input break action : Up-scale •Input short action : Down-scale •For DC current input, connect a 250 Q resister to the input terminals. •Refer to the Input and Range and Input Code Table for details. •Input break action : Down-scale •Both Heat/Cool control outputs are OFF for Heat/Cool PID...
Open the catalog to page 31 Type R,S and B input : Accuracy is not guaranteed between 0 and 399°C (0 and 799°F). 2 Type T and U input : Accuracy is not guaranteed less than -100.0°C (-158.0°F). 3 DC current input : A 250 Q resistor is externally connected at the input terminals.
Open the catalog to page 4Temperature Controller Alarm Code Table 3
Open the catalog to page 5Temperature Controller External Dimensions and Rear Layout Units : mm Panel Cutout