1. Catalogs
  2. RKC INSTRUMENT INC
  3. REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900

REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900

REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900

REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900

Product catalog summary
General Description
The REX-C Series controllers, including models C100, C400, C410, C700, and C900, are designed for precise temperature control at a reasonable cost. These controllers are available in five DIN sizes and are known for their reliability and ease of use. Key features include dual displays, autotuning, PID algorithm, selectable °C/°F, reverse or direct action, and a range of temperature alarms.
Features
The controllers offer Heat/Cool PID control, standard autotuning, heater and loop break alarms, and various control outputs. They support field-configurable thermocouples and are designed to save energy by allowing overlap or deadband settings. The Heat/Cool control is not available on the REX-C100 model.
Heater Break Alarm (HBA)
The HBA detects faults in heating or cooling circuits and displays actual amperage on the front panel. It requires a current detector and is available for three-phase systems. The HBA function is optional and requires specific current transformers.
Loop Break Alarm (LBA)
The LBA monitors the entire temperature control system, detecting heater breaks, thermocouple or RTD failures, and short circuits. It activates when the PID value reaches 100% or 0% without a corresponding temperature response. The LBA is optional and not available for triac trigger output or heat/cool types.
Specifications
  • Input Types: Thermocouple, RTD, DC voltage, and DC current.
  • Sampling Time: 0.5 seconds.
  • Measuring Accuracy: Varies by input type, generally ±0.5% of reading.
  • Insulation Resistance: More than 20MΩ at 500V DC.
  • Dielectric Strength: 1000V AC for measured and ground terminals, 1500V AC for power and ground terminals.
  • Control Method: PID control with autotuning, available for reverse and direct action.
  • Control Output: Relay, voltage pulse, current, and triac trigger outputs.
  • Temperature Alarm: Up to 2 points with various alarm actions.
  • Supply Voltage: 85 to 264V AC, 24V AC, or 24V DC.
  • Operating Environment: 0 to 50°C, 45 to 85% RH.
Compliance
The controllers comply with CE Mark and UL/cUL standards, except for triac trigger output types.
Model and Suffix Code
The document provides detailed model and suffix codes for configuring the controllers based on control method, output type, input range, and alarm settings.
See more

Catalog excerpts

REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900-1

Digital Temperature Controller CENTURY Series REX-C100 REX-C400 REX-C410 REX-C700 REX-C900 General Description The Century Series controllers are designed for precise control performance at the most reasonable cost. Available in five DIN sizes, these instruments are recognized for their solid reliability and ease-of-use. This Series features dual displays, autotuning, PID algorithm, field-selectable °C/°F, reverse or direct action and a full range of temperature alarms. Features Heat/Cool Control Standard autotuning Heater and loop break alarm Numerous control outputs Field-configurable thermocouples Loop Break Alarm The control loop break alarm (LBA) monitors and protects an entire temperature control system. The LBA detects heater breaks, thermocouple or RTD failures, short circuits, or the failure of an operating device such as a mechanical or solid state relay. The Heat/Cool PID control features heat and cool outputs for use where process-generated heat exists. This allows the input of overlap or deadband settings which contribute to energy savings. (Not available on REX-C100) When the PID computed value reaches 100% and the temperature does not respond in a set time, the loop break alarm is activated. Conversely, when the PID value reaches 0% and the temperature does not respond accordingly, the loop break alarm is turned on. In this example, the LBA uses reverse action to control heat. For cool control, the LBA action is reversed and becomes direct. LBA deadband is available to suppress the influence of external disturbances. Heater Break Alarm Standard Features Heat/Cool Control The heater break alarm (HBA) detects a fault in heating or cooling circuit and displays actual amperage on the front panel. If the measured value becomes lower than the preset value, the alarm is activated. The HBA function requires a current detector for measuring and monitoring the current load. HBA for three phase is available. Contact RKC for details. The Century Series offers full PID Control, autotuning on demand, °C/°F, Reverse or Direct action, PV Bias, anti-reset windup and operator lock-out function. Twelve different field-configurable thermocouple types inputs, RTD, DC milliamp or voltage inputs as well as relay, voltage pulse, 4-20 mA and triac trigger outputs are available. Sensor Actuator Heater Controlled object

 Open the catalog to page 1
REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900-2

Digital Temperature Controller CENTURY Series SpecificationsInput Alarms (Optional) Input (Universal input) a) Thermocouple : K, J, R, S, B, E, T, N (JIS/IEC), PLII (NBS) •Influence of external resistance : Approx. 0.35pV/Q •Input break action : Up-scale •Influence of input lead resistance : Approx. 0.01[%/Q] of reading •Input break action : Up-scale •Input break action : Down-scale •Input break action : Down-scale Temperature Alarm a) Number of alarm : 2 points (Maximum) b) Alarm action : Deviation High, Low, High/Low, Band c) Alarm differential gap : 2°C (°F) or 2.0°C (°F) as standard. Heater...

 Open the catalog to page 2
REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900-3

• Field programmable among following input group 1 Type B input : Accuracy is not guaranteed between 0 and 399°C (0 and 799°F) Supply Voltage Alarm Code Table b Code

 Open the catalog to page 3
REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900-4

Digital Temperature Controller CENTURY Series External Dimensions and Rear Terminals (Unit : mm) • Use 6.2mm or less solderless terminal. • Use 6.2mm or less solderless terminal. No. 1-10 (Power, Alarm and Output terminals) • Use 8.1mm or less solderless terminal. • Use 8.1mm or less solderless terminal.

 Open the catalog to page 4

All RKC INSTRUMENT INC catalogs and technical brochures

  1. VGR-B100

    8  Pages

  2. PF900

    8  Pages

  3. MA901

    6  Pages

  4. MA900

    6  Pages

  5. COM-ME-1

    2  Pages

  6. SRX

    8  Pages

  7. SRZ

    12  Pages

  8. SB1

    8  Pages

  9. REX-F9000

    3  Pages

  10. HA930

    6  Pages

  11. GZ400 / GZ900

    12  Pages

  12. FB400 / FB900

    12  Pages

  13. FB100

    8  Pages

  14. SA200

    6  Pages

  15. SA100

    6  Pages

  16. RZ SERIES

    4  Pages

  17. SB1 Series

    8  Pages

  18. RB SERIES

    8  Pages

  19. AG500

    108  Pages

  20. PRODUCT CATALOG

    167  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.