Makes the machine look sharp. The outstanding design of the FZ which is beyond the common image of panel meters dramatically changes the first impression of your machine. • Three Indicators • Thin bezel • Selectable PV (Universal input) • Selectable Remote input (Universal input) • Measuring Accuracy : ±0.1% of reading • Selectable Control method (Heat/Cool) • Easy maintenance with plug-in construction (FZ400/900) • Easy data back up through the front loader port Wide range display (5 digits) SEuuu
Open the catalog to page 2Customizable versatile information display Three Indicators (FZ400/900) FZ400 FZ900 • CT and CT input hardware are required. (Option) Enables display of load factor of the heater controlling the process and detects potential errors at an early stage. Selectable Display Control Output : % Memory Area Soak Time (Progress time of segment) : H:M / M:S Current transformer (CT) Input Value : A High accuracy type CT(CTL-6-P-Z) can be used too. Accurately measures current 1A or less. PV is available in green or white (U.R.D.Co.,LTD product) Measured range : 0.0 to 10.0A Accuracy : ±0.3A Display Customization...
Open the catalog to page 32 inputs for various applications • Two-input type is available for FZ400/900 only. C CH2 Control output CH1 C Control output Cascade Control (Control loop combination function) Master (Sterilizing temperature) Slave (Inside temperature) Available with functions related to Cascade control and dedicated Autotuning. Control with PV select Automatic Selection High Temperature Reactor This is a function to switch between Input 1 and Input 2 at a preset temperature. • This function may be appropriate in such an application where a thermocouple (whose operating temperature range is relatively low)...
Open the catalog to page 4Advanced control performance and function Suppresses fluctuations due to overshoot and external disturbance. Suppressing Overshoot Proactive Function Bottom suppression function Proactive function suppresses overshoot and provides fast and stable control. Adjustable Proactive Intensity allows the FZ to be tuned appropriate for various process applications. Determines response based on the deviation amount and speed and adjusts the PID factors using fuzzy logic operation. When the input fluctuation by external disturbance is detected, the amount of FF (Feed forward) is added to the output value...
Open the catalog to page 5Easy connection to PC and PLC A loader communication port is available on the 48mm square sized front panel FZ400 All models are supplied with a front loader port as standard. Configuration software can be used without removing the controller from the panel. The power to COM-K2 is supplied from the PC via ia the USB port so no power supply is necessary. Front loader communication port E Easy D Data t Management M t Loader communication cable Length : 1.5m Model code for cable only : W-BV-05-1500 Communication Tool Data monitoring, setting, storage, copy, transfer, logging, and report creation...
Open the catalog to page 6Functions and performance designed for easy maintainability Easy Maintenance The internal assembly of the FZ400/900 can be removed from the front. Flexible output allocation is possible Control output (Heat/Cool) (*2) Control output (Position proportioning)(*2) OUT1,OUT2 : Relay contact/Voltage pulse/Current/ Continuous voltage/Transistor output OUT3 : Voltage pulse/Current (Universal output) DO1, DO2, DO3, DO4 *1 : Relay contact Output type is freely changeable to meet the requirements of different applications. Event output LBA output HBA output RUN status monitor output Output of communication...
Open the catalog to page 7Measured Input (Universal Inputs) Number of inputs FZ400/FZ900 : Max. 2 points • Isolated between each channel FZ110 : 1 point Influence of external resistance : Approx. 0.18^V/Q (Thermocouple input) Influence of lead resistance : Approx. 0.006% of Span/Q (RTD input) • Maximum 100Q per wire Input impedance (Voltage/Current Input) Low voltage : 1MQ, or more, High voltage : 1MQ or more Current : Approx. 50Q, Input Break Action Thermocouple input : Up-scale/Down-scale (Selectable) Low voltage input : Up-scale/Down-scale (Selectable) Current input : Value around 0mA High voltage input : Value around...
Open the catalog to page 8Output signal : OUT1,2 : Relay contact output, Voltage pulse output, Current output, Continuous voltage, Transistor output OUT3 : Voltage pulse, Current output (Universal output) DO1, DO2 (FZ110) : Relay contact output DO1 to DO4 (FZ400/900) : Relay contact output Output function : Control output (Heat/Cool), Event output,, LBA (Control loop break alarm output), HBA (Heater break alarm output), RUN status monitor, Output of communication monitoring result Manual status output, Remote statusa output, AT status output, SV change status output, FAIL output, Retransmission output Number of event/alarm...
Open the catalog to page 9Q Model and Suffix CodesFZ400/900 ® @ (D®(D©(z)®(D@©@ 48 x 96mm (1/8 DIN Vertical size) FZ400 □ □□□-□ □ □ □ □ □ □/□ C) Output Code Table
Open the catalog to page 10Loop break alarm (LBA) Initial setting code: The output allocation has LBA output : 480 The output allocation has no LBA output:
Open the catalog to page 11* Use a solderless terminal for screw size M3, width 5.8mm or less. C149FZ10E Printed in Japan : FEB.2025 All Rights Reserved.
Open the catalog to page 128 Pages
4 Pages
8 Pages
6 Pages
6 Pages
2 Pages
8 Pages
12 Pages
8 Pages
3 Pages
6 Pages
12 Pages
12 Pages
8 Pages
6 Pages
6 Pages
4 Pages
8 Pages
8 Pages
108 Pages
167 Pages